Installation Manual
9
Figure 3: Alarm/Relay/Audio Connector
9. FCC Class A installations: Attach the ferrite (supplied) to the network cable. Attach the ferrite on the cable as close as possible to
the camera’s RJ-45 network port.
WARNING: The ferrite must be installed for the camera to meet FCC Class A compliance standards. Failure to correctly install the
ferrite can cause harmful interference to radio communications.
Figure 4: Installing the Ferrite: In-Ceiling Models
Installing the Back Box (Pendant)
1. Install the pendant mount (not supplied). Refer to the instructions supplied with the mount.
2. Pull the wiring into the back box.
# Connection/Feature Description
1 24 VAC Power Supplies power to the camera, and operates heater and blower in environmental units.
2 PoE+/HPoE Switch Switch to choose between PoE+ and HPoE. Must be set to the correct position based on the type of PoE
injector used.
3 RJ-45 Network Port Connects the camera to the IP network and supplies power to the camera through the network using
Power over Ethernet (PoE+ or HPoE). PoE+ will also operate blower in environmental units. HPoE will
also operate heater and blower in environmental units.
4 Alarm, Relay, and Audio
In/Out
An 8-pin connector with one alarm, one relay, and audio in and out.
5 Power LED This LED glows solid green when the power is on. The LED is off when there is no power.
RA