® PS30A and PS30-24 Scanners Installation/ Operation Manual C360M-I (11/99) Pelco • 3500 Pelco Way, Clovis • CA 93612-5699 USA • www.pelco.
CONTENTS Section Page IMPORTANT SAFEGUARDS AND WARNINGS ................................................................ 3 DESCRIPTION ................................................................................................................... 3 MODELS .................................................................................................................... 3 INSTALLATION ...................................................................................................................
IMPORTANT SAFEGUARDS AND WARNINGS Prior to installation and use of this product, the following WARNINGS should be observed. 1. Installation and servicing should only be done by qualified service personnel and conform to all local codes. 2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X ,6 or 6P enclosure, it is designed for indoor use only and it must not be installed where exposed to rain and moisture. 3. The camera and lens combined weight shall not exceed 50 pounds (23 kg).
2. If you installed the scanner in an upright position, remove the 10-32 Allen screw from the bottom plate. If you installed the scanner in an inverted position, remove the 10-32 Allen screw from the top plate. Retain the screw. 3. Center (balance) the camera and lens, or enclosure, camera, and lens load on the tilt table. Adjust the positioning as needed to align the mounting holes. Mount the camera or enclosure to the tilt table with two 1/4-20 hex head bolts (not supplied).
Table A. Cable Distances* Model Wire Size (AWG) Maximum Distance “A” Maximum Distance “B” PS30A 20 18 16 5,800 ft (1,768 m) ** 8,250 ft (2,515 m) 13,000 ft (3,962 m) 2,467 ft (752 m) 3,925 ft (1,196 m) 6,229 ft (1,899 m) PS30-24 20 18 16 5,800 ft (1,768 m) ** 8,250 ft (2,515 m) 13,000 ft (3,962 m) 118 ft (35 m) 188 ft (57 m) 298 ft (90 m) A NOTE: If RB24 or RB115 Relay Box is not used, maximum cable length is distance “B.
Figure 4. Control Unit Wiring Figure 5. Limit Adjustments LIMIT STOP ADJUSTMENTS To set pan limit stops, perform the following steps. Refer to Figure 5. WARNING: Do not operate the scanner without limit stops. Do not attempt to adjust the limit stops while the unit is operating. Personal injury or damage to the unit may result. Do not remove or reposition the fixed limit stop on the scanner. DAMAGE WILL OCCUR. 1. Loosen the pan limit stops. 2. Operate the scanner.
SPECIFICATIONS MECHANICAL Pan: 0-355° movement in horizontal plane Speed: 6°/sec ±.5° Maximum Load: 50 lb (23 kg) centered Operation: Upright or inverted Bearings: Heavy-duty ball bearings Overload Protection: Thermal protected ELECTRICAL Input Voltage PS30A: PS30-24: 120 VAC 24 VAC Power Requirements PS30A: 250 mA (28.
WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Exceptions to this warranty are as noted below: • Five years on FT/FR8000 Series fiber optic products. • Three years on Genex® Series products (multiplexers, server, and keyboard).