INSTALLATION/OPERATION Spectra IV SL and Spectra IV SE Series ® 23X, 27X, and 35X Dome Drives C3463M (10/09)
Contents Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Switch Settings. . . . . . . . . . . . . . . .
Low Lux Noise Reduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Wide Dynamic Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Motion Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Description Spectra® IV SL and Spectra IV SE are Pelco’s premier integrated dome systems. These systems feature a high resolution camera/optics package with configurable dome drive software. This manual is designed primarily to be a reference tool for the installation and operation of your system. Inside you will find information about features and commands, as well as a detailed menu tree and a quick start guide.
Installation This manual contains installation instructions for the Spectra IV dome drive only. For complete installation instructions for a Spectra IV dome system, refer to the installation manual that was shipped with the back box. SWITCH SETTINGS Before installing the dome drive, you must configure the receiver address, termination, and baud setting. The DIP switches used to configure these settings are located on the base of the dome drive. Figure 1 shows the default settings for the DIP switches.
Pelco P Protocol Control Systems To compensate for Pelco P protocol control systems from other manufacturers, set SW2-3 to the ON position. This may improve dome control with some of these control systems. SW2 SWITCHES 4 AND 5: SERIAL PORT SETTINGS RS-422 Setting (Default) SW2-4 and SW2-5 should both be set to the OFF position for RS-422 setting. For control, only two wires should be connected to the RX- and RX+ connectors on the circuit board inside the back box.
DOME DRIVE To install the dome drive: 1. Align the blue and red tabs with the blue and red arrows on the hinged door inside the back box. 2. Push the tabs in. Insert one side and then the other side. 3. Continue pushing on the ends of the tabs until both sides click into place (refer to Figure 2). Figure 2. Dome Drive Installation Note: When removing a dome drive that has been in use, caution should be taken to avoid direct contact with the top plate of the unit.
Operation QUICK OPERATION GUIDE Pan and Tilt Move the joystick or press the direction keys left/right and up/down. Zoom Far To zoom far: 1. Press the Zoom Tele button or turn the joystick clockwise until zoom stops at the optical zoom limit. 2. Release the button or joystick for one second. 3. To continue zooming (digitally), press the button or turn the joystick clockwise again until you have the picture you want or reach the digital zoom* limit.
PRESET 95: ACCESSING MAIN MENU You can call up the main menu on your monitor by configuring (setting or creating) preset 95 (preset 28 in AD-32 preset mode). Configuring preset 95 for Pelco’s controllers varies according to the type of controller you are using. Instructions for configuring preset 95 are given below for various Pelco controllers. CM6700/CM6800 1. Enter the number of the Spectra IV dome system and press the CAM key. 2. Enter 95 and hold the PRESET key for two seconds. 3.
ENDURA WORKSTATION 1. Right-click in the video pane of the Spectra IV dome system. 2. Click Preset and then click Select Preset. 3. Enter 95 and then click OK. VCD5000 1. Enter 95 for the preset action. The shortcuts menu appears. 2. Press the Preset button on the KBD5000. DX4100/DX4500/DX4600/DX8100 1. Click the PTZ button on the toolbar. The PTZ control appears. 2. Click the Program button on the PTZ control. The main menu appears. DIGITAL SENTRY® SYSTEM SOFTWARE 1. Click the PTZ tab. 2.
23X LowLight Day/Night Menu Tree SPECTRA IV LANGUAGE ACK ALERT* ENGLISH RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM SYSTEM INFORMATION DISPLAY SETUP SERIAL # XXXXXXXXXXXXXX DOME DRIVE MODEL XX-XXXX AVAILABLE BACK BOX MEMORY XX.X SOFTWARE VERSION BUILD XX.X FONT VERSION XXXXXXXXXX COMM 1 D ADDRESS 2 P ADDRESS OFF CM95OO MODE OFF 32 PRESETS C PROTOCOL X.
DOME SETTINGS * LINE SYNC LINE SYNC LINE SYNC PHASE PRESETS ON 0 ALARMS RESUME SEQUENCE (SECS) RESET DELAY (SECS) C3463M (10/09) PATTERNS 1 ALARM NUMBER ALARM PRIORITY ALARM ACTION ACTIVATE AUX ALARM CONTACT OFF 1234567890 ABCDEFGHIJ KLMNOPQRST UVWXYZ.
27X LowLight Day/Night Menu Tree SPECTRA IV LANGUAGE ACK ALERT* ENGLISH RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM SYSTEM INFORMATION DISPLAY SETUP SERIAL # XXXXXXXXXXXXXX DOME DRIVE MODEL XX-XXXX BACK BOX MEMORY AVAILABLE SOFTWARE VERSION XX.X BUILD FONT VERSION XX.X COMM XXXXXXXXXX D ADDRESS 1 P ADDRESS 2 CM95OO MODE OFF 32 PRESETS OFF PROTOCOL C PRESSURIZED* X.
DOME SETTINGS * LINE SYNC LINE SYNC LINE SYNC PHASE PRESETS ON 0 ALARMS RESUME SEQUENCE (SECS) RESET DELAY (SECS) EDIT THE PASSWORD 1234567890 ABCDEFGHIJ KLMNOPQRST UVWXYZ.
35X LowLight Day/Night Menu Tree SPECTRA IV LANGUAGE ACK ALERT* ENGLISH RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM SYSTEM INFORMATION DISPLAY SETUP SERIAL # XXXXXXXXXXXXXX DOME DRIVE MODEL XX-XXXX BACK BOX MEMORY AVAILABLE SOFTWARE VERSION XX.X BUILD FONT VERSION XX.X COMM XXXXXXXXXX D ADDRESS 1 P ADDRESS 2 CM95OO MODE OFF 32 PRESETS OFF PROTOCOL C PRESSURIZED* X.
DOME SETTINGS * LINE SYNC LINE SYNC LINE SYNC PHASE PRESETS ON 0 ALARMS RESUME SEQUENCE (SECS) RESET DELAY (SECS) EDIT THE PASSWORD 1234567890 ABCDEFGHIJ KLMNOPQRST UVWXYZ.
Language SPECTRA IV LANGUAGE ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT The language for the on-screen menus is selectable. Available languages include English, Spanish, French, German, Italian, Portuguese, Russian, Polish, Turkish, and Czech. The factory default language is English. To change the display language: 1. Use the joystick to position the cursor beside LANGUAGE. 2. Press Iris Open.
System Information SYSTEM INFORMATION SPECTRA IV LANGUAGE ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT SERIAL # DOME DRIVE MODEL BACK BOX MEMORY SOFTWARE VERSION BUILD FONT VERSION ADDITIONAL FREE MEMORY LAST RESET AZIMUTH ZERO OFFSET MOTOR ACTIVE CAMERA ACTIVE VIDEO LEVEL CAMERA MODEL LANGUAGE 1 LANGUAGE 2 LANGUAGE 3 LANGUAGE 4 LANGUAGE 5 LANGUAGE 6 LANGUAGE 7 LANGUAGE 8 LANGUAGE 9 LANGUAGE 10 COMM D ADDRESS P
Display Setup DISPLAY SETUP SPECTRA IV LANGUAGE ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT PRESET LABEL ZONE LABEL ZOOM AZIMUTH/ELEVATION DIRECTION ALARM MESSAGE DATE/TIME EVENT LABEL
LABEL POSITIONS DISPLAY SETUP SPECTRA IV LANGUAGE ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT PRESET LABEL ZONE LABEL ZOOM AZIMUTH/ELEVATION DIRECTION ALARM MESSAGE DATE/TIME EVENT LABEL
Dome Settings CAMERA DOME SETTINGS SPECTRA IV LANGUAGE ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT * BACK EXIT CAMERA TYPE OF LIGHTING AUTO FOCUS SURE FOCUS ZOOM LIMIT ZOOM SPEED LOW LIGHT LIMIT IR CUT FILTER LOW LIGHT FOCUS AUTO IR LEVEL BACK EXIT TYPE OF LI
ZOOM SPEED (Applies only to 27X and 35X models.) Zoom speed allows the user to define the speed at which the dome will go from full wide zoom to the optical zoom. The zoom speed is set to 4.2 seconds and cannot be changed for 23X models. Available zoom speed settings for 27X and 35X models include: HIGH: 3.2 seconds MEDIUM (default): 4.6 seconds LOW: 6.6 seconds Note: When using the HIGH setting, the image may be out of focus until zooming stops. LOW LIGHT LIMIT (Applies only to 27X and 35X models.
IR CUT FILTER Spectra IV dome systems have two modes of operation: color, and black-white. You can increase sensitivity in low light conditions by switching to black-white mode (removing the IR cut filter). Color mode is preferred in normal lighting conditions. The following are the settings for the IR cut filter: OFF: Manual operation is controlled by preset 88 (filter IN) and 89 (filter OUT). AUTO (default): Automatic operation is controlled by the auto IR level setting.
ADVANCED CAMERA SETTINGS SPECTRA IV LANGUAGE ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT DOME SETTINGS * BACK EXIT CAMERA TYPE OF LIGHTING AUTO FOCUS SURE FOCUS ZOOM LIMIT ZOOM SPEED LOW LIGHT LIMIT IR CUT FILTER LOW LIGHT FOCUS AUTO IR LEVEL BACK EXIT ADVANCE
Auto Iris Peak Increasing the peak value will cause the auto iris circuit to react more to highlights or “peaks” in the picture. Decreasing this value will cause it to use the average video level to adjust the iris. AUTO SHARPNESS Auto sharpness enhances picture detail by increasing the aperture gain of the camera and sharpening the edges in the picture. There are two settings: ON (default): The camera automatically maintains a normal sharpness mode.
SENSOR SCAN MODE (Applies only to 27X and 35X models.) Sensor scan mode controls the internal processing of the camera's image sensor. The data scanned from the image sensor at each field time is used for the internal image control algorithms and digital signal processing (DSP). Note: When changing from PROGRESSIVE to INTERLACED, or vice-versa, the camera restarts to establish the new setting.
IMAGE ENHANCEMENT (Applies only to 35X models.) The image enhancement feature improves the definition of objects, lines, or text in high contrast areas, making them appear sharper. There are two image enhancement settings: DEFAULT: Image enhancement is not activated. ENHANCED: Image enhancement is activated. Warning: When using this feature be aware that picture noise, although unnoticeable to the eye, will increase and may cause compression rate changes in DVRs, NVRs, and network devices.
MOTION SETTINGS ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT MOTION DOME SETTINGS SPECTRA IV LANGUAGE * BACK EXIT AUTO FLIP PROPORTIONAL PAN PARK TIME (MINUTES) PARK ACTION SCAN SPEED (DEG/S) PRESET FREEZE FRAME LIMIT STOPS
PARK TIME This feature allows the dome to begin a specified operation (scan, preset, or pattern) after a configured period of inactivity. Park time can be configured from 1 to 720 minutes (12 hours), or set to zero, which disables this feature. The default setting is zero. Park Action This feature will define the activity when the dome parks. The following settings are available: NONE (default): No action. AUTO SCAN: Dome starts auto scan operation. RANDOM SCAN: Dome starts random scan operation.
To set manual or scan stops: 1. Use the joystick to position the cursor beside SET MANUAL STOPS or SET SCAN STOPS. 2. Press Iris Open. 3. Follow the directions displayed on the monitor. Note: In order for the manual or scan stops to work, the LIMIT STOPS option must be ON. To clear manual or scan stops: 1. Use the joystick to position the cursor beside CLEAR MANUAL STOPS or CLEAR SCAN STOPS. 2. Press Iris Open. 3. Follow the directions displayed on the monitor.
POWER UP (Applies only to 27X and 35X models.
LINE SYNC SPECTRA IV LANGUAGE ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT DOME SETTINGS * BACK EXIT LINE SYNC LINE SYNC LINE SYNC PHASE BACK EXIT Line sync refers to a configurable function that allows you to synchronize all cameras within a matrix system.
PRESETS DOME SETTINGS SPECTRA IV LANGUAGE PRESETS PRESET NUMBER * * * PRESET NOT DEFINED * * * * BACK EXIT ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT 1
Note: For American Dynamics™ controllers with only 32 presets, switch SW2-1 on the dome drive to the ON position. When SW2-1 is ON, several presets change (refer to Table D). Table D. Presets for American Dynamics Controllers Spectra IV Presets American Dynamics Controller Presets 88 21 89 22 90 23 91 24 92 25 93 26 95 28 96 29 97 30 98 31 99 32 If the limit stops are turned off, presets 23 to 26 can be used as regular presets. Use the following steps to configure a preset. 1.
4. Edit preset camera settings: a. Use the joystick to position the cursor beside EDIT CAMERA SETTINGS. b. Press Iris Open. The EDIT CAMERA SETTINGS window appears. Refer to Camera on page 22 and Advanced Camera Settings on page 25 to change preset camera settings. c. To edit the camera settings schedule, use the joystick to position the cursor beside EDIT SCHEDULE. Press Iris Open. The Edit Schedule menu is a duplicate of the Edit Event menu (refer to Event on page 54) with the following exceptions.
MOTION DETECTION (Applies only to 27X and 35X models.
MOTION DETECTION AREAS Figure 4. Motion Detection Areas 2. Set the sensitivity of the motion detection area: a. Position the cursor next to SENSITIVITY for DETECTION AREA 1, 2, 3, or 4. b. Press Iris Open, the cursor moves to the right. c. Use the joystick to select one of the following sensitivity levels: HIGH: The sensitivity level is high. MEDIUM (default): Average sensitivity. LOW: The sensitivity level is low. d. Press Iris Open to make selection.
PATTERNS SPECTRA IV LANGUAGE ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT DOME SETTINGS * BACK EXIT PATTERNS PATTERN NUMBER BACK EXIT REFERENCE INFORMATION PATTERN USAGE REMAINING A pattern is a memorized, repeating series of pan,
ZONES SPECTRA IV LANGUAGE ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT DOME SETTINGS ZONES ZONE NUMBER * * * ZONE NOT DEFINED * * * * BACK EXIT ZONE ENABLED ZONE BLANKING BACK EXIT A zone is a pan area, defined by a left and right limit
WINDOW BLANKING DOME SETTINGS SPECTRA IV LANGUAGE * BACK EXIT ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT WINDOW BLANKING SET WINDOWS STYLE WINDOW NUMBER BLANK ALL ABOVE BLANK ALL BELOW ENABLE WINDOW
6. The blanked area can be configured to turn on or off at a specified zoom point. To set the zoom point: a. Use the joystick to position the cursor beside EDIT WINDOW ZOOM, and then press Iris Open. b. Zoom in to the point where you want window blanking to turn on. Press Iris Open to set the zoom point. Notes: • Since the area is already blanked out, it may be difficult to determine when you want window blanking to turn on. Reverse the window before setting the zoom point.
BLANK ALL ABOVE/BLANK ALL BELOW The Blank All Above and Blank All Below options add additional flexibility to setting up privacy areas. These settings are ideal for applications where a complete pan location needs to be blanked. Table E.
ALARMS DOME SETTINGS SPECTRA IV LANGUAGE ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT * BACK EXIT ALARMS RESUME SEQUENCE (SECS) RESET DELAY (SECS) BACK EXIT ALARM SETTINGS ALARM NUMBER ALARM PRIORITY ALARM ACTION ACTIVATE AUX ALARM CONTACT BACK EX
4. Set the alarm action: a. Use the joystick to position the cursor beside ALARM ACTION. b. Press Iris Open. The cursor moves to the right. c. Move the joystick up or down to view the available selections. The following are the settings for alarm action: NONE: No action when alarm is triggered. PRESET: Dome goes to the preset that is the same as the alarm number. Preset 1 will go to Alarm 1. PATTERN 1: Dome runs pattern 1 when alarm is triggered. PATTERN 2: Dome runs pattern 2 when alarm is triggered.
6. Set the alarm contact: a. Use the joystick to position the cursor beside ALARM CONTACT. b. Press Iris Open. The cursor moves to the right. c. Move the joystick up or down to view the following available selections. N/O (default): Normally open. N/C: Normally closed. d. Press Iris Open to enter selection. Note: The alarm contact feature is functional and available for 23X models only if the dome drive is installed in a Spectra III SE or Spectra IV SE back box. 7.
AUX SPECTRA IV LANGUAGE ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT DOME SETTINGS * BACK EXIT AUX AUX 1 MODE DWELL TIME (SECS) AUX 2 MODE DWELL TIME (SECS) TOGGLE 1 TOGGLE 1 BACK EXIT An auxiliary output is a configurable signal from the dome back box that can t
TITLE TEXT SPECTRA IV LANGUAGE ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT DOME SETTINGS TITLE TEXT * BACK EXIT ENABLE TITLE TEXT BACK EXIT Title text is the label used to identify the camera viewed on the monitor. Up to 20 characters can be used for a title.
ALERT DOME SETTINGS SPECTRA IV LANGUAGE ACK ALERT RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT ALERT REPEAT ACK ACTION ACTIVATE AUX RESET ALERT BACK EXIT BACK EXIT Note: The Alert option applies only to Pressurized Spectra IV dome systems.
ACTIVATE AUX This setting activates an auxiliary when an alert condition exists. Settings include the following options: NONE (default): Not activated. 1: An alert condition will close AUX 1. 2: An alert condition will close AUX 2. CURRENT READING The Current Reading menu displays the existing status of temperature, pressure, and dew point inside the dome system. An arrow displayed to the left of a menu item denotes that an alert condition exists.
CLEAR SPECTRA IV LANGUAGE ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT DOME SETTINGS * BACK EXIT CLEAR CLEAR ALL ZONES CLEAR ALL PRESETS CLEAR ALL PATTERNS CLEAR ALL WINDOW BLANKING CLEAR ALL EVENTS RESTORE FACTORY DEFAULTS BACK EXIT Use this setting to clear user-defined settings
CLOCK ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT CLOCK DOME SETTINGS SPECTRA IV LANGUAGE * BACK EXIT TIME BASE TIME FORMAT SET TIME DATE FORMAT SET DATE DAYLIGHT SAVINGS BACK EXIT The clock is used to set the current date and time.
7. If FIXED DATE was selected, the following information appears: CLOCK TIME BASE TIME FORMAT SET TIME INTERNAL CLOCK 12 HOUR 00:00 AM DATE FORMAT SET DATE MM/DD/YYYY 00/00/0000 DAYLIGHT SAVINGS TIME SHIFT START DATE MONTH DAY START TIME FIXED DATE 1 HOUR APRIL 1 02:00 AM END DATE MONTH DAY END TIME OCTOBER 1 02:00 AM BACK EXIT a. Use the joystick to position the cursor beside TIME SHIFT. Press Iris Open. Scroll through the options until the desired selection appears.
EVENT (Applies only to 27X and 35X models.
EVENT LABEL Set the event label to NEW to create a new event. Use the following steps to manage an existing event. 1. Use the joystick to position the cursor beside EVENT LABEL. Press Iris Open. 2. Move the joystick up or down to scroll through the events. Press Iris Open to enter selection. As you scroll through the events, the reference information at the bottom of the screen displays the corresponding details for each event. To view a list of all events and their details, refer to List Event on page 56.
d. Follow the instructions in the previous step for the remaining days of the week. e. Use the joystick to position the cursor beside HOLIDAY. Press Iris Open. The following are the holiday settings: SKIP HOLIDAYS: The event will not occur on a day of the week for which it is set if that date is in the list of holidays. ON: The event will activate on holidays that are set in the Event menu, in addition to its normally scheduled days of the week.
4. If FIXED DATE was selected as the occurrence, the following information appears: EDIT HOLIDAY OCCURRENCE MONTH DAY FIXED DATE JANUARY 1 BACK EXIT a. Use the joystick to position the cursor beside MONTH. Press Iris Open. Scroll through the options until the desired month appears. Press Iris Open to select the month. b. Use the joystick to position the cursor beside DAY. Press Iris Open. Scroll through the options until the desired date appears. Press Iris Open to select the day. 5.
SCHEDULED EVENTS Use this page to record scheduled events. EVENT NUMBER EVENT TYPE LABEL TIME OCCURS HOLIDAY Example: 1 Preset Weekend 11:00 AM Sat–Sun Skips Holidays Description: Camera focuses on gate on weekends when the office is closed.
Reset, Cycle Power, Reboot SPECTRA IV LANGUAGE ENGLISH ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT RESET CAMERA Use this function to reset all camera settings to factory default parameters. CYCLE CAMERA POWER If the camera is not operating or if you lose camera control, cycle camera power. Cycling camera power resets the camera but does not change any saved camera settings.
Software/Language File Upload The RJ-45 data port of the dome drive allows access for on-site setup, testing, and uploading of revised operating software and language files. A Pelco field service tool is required to perform these operations. Field service tools include Pelco’s remote monitor kit (IPS-RMK), remote data port box (IPS-RDPE-2), and remote monitor cable (IPS-CABLE).
Maintenance The Spectra IV dome systems do not require any special maintenance. Occasionally, dust may build up on the inside or the outside of the dome. If this occurs, turn power off to the unit and remove the lower dome from the back box. Remove the dust from the lower dome using compressed air from a spray can. Replace the lower dome following the installation instructions that were shipped with it. Warning: Proper eye protection should be worn when using compressed air cans.
Specifications 23X MODELS DD423 Signal Format NTSC Scanning System 2:1 Interlace Image Sensor 1/4-inch progressive scan CCD Effective Pixels 768 (H) X 494 (V) Horizontal Resolution 540 TV lines Lens f/1.6 (focal length, 3.6~82.8 mm; 23X optical zoom, 12X digital zoom) Zoom Speed (optical range) 2.9/4.2/5.8 seconds Horizontal Angle of View 54° at 3.6 mm wide zoom; 2.5° at 82.8 mm telephoto zoom Focus Automatic with manual override Maximum Sensitivity at 35 IRE 0.025 lux at 1/2 sec.
27X MODELS DD427 Signal Format NTSC Scanning System 2:1 Interlace/1:1 Progressive (user-selectable) Image Sensor 1/4-inch CCD Effective Pixels 768 (H) X 494 (V) Horizontal Resolution >540 TV lines Lens f/1.4 (focal length, 3.4~119 mm; 35X optical zoom, 12X digital zoom) Zoom Speed (optical range) 3.2/4.6/6.6 seconds Horizontal Angle of View 55.8° at 3.4 mm wide zoom; 1.7° at 119 mm telephoto zoom Focus Automatic with manual override Maximum Sensitivity at 35 IRE 0.55 lux at 1/60 sec.
35X MODELS DD4CBW35 Signal Format NTSC Scanning System 2:1 Interlace/1:1 Progressive (user-selectable) Image Sensor 1/4-inch CCD Effective Pixels 768 (H) X 494 (V) Horizontal Resolution >540 TV lines Lens f/1.4 (focal length, 3.4~119 mm; 35X optical zoom, 12X digital zoom) Zoom Speed (optical range) 3.2/4.6/6.6 seconds Horizontal Angle of View 55.8° at 3.4 mm wide zoom; 1.7° at 119 mm telephoto zoom Focus Automatic with manual override Maximum Sensitivity at 35 IRE 0.55 lux at 1/60 sec.
Appendix Table F.
Table G.
Table G.
Table G.
Table G.
Table G.
Table G.
C3463M (10/09)
PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment.
www.pelco.com Pelco, Inc.