I N S T A L L A T I O N 090 Series Camclosure® Indoor Integrated Camera System Surface Mount/In-Ceiling C2462M-D (3/08)
Contents Important Safety Instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Regulatory Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Parts List. . . . . . . . .
List of Illustrations 1 2 3 4 5 6 7 8 9 10 11 12 13 How to Remove the Dome Bubble . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Ceiling/Wall Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Concrete Ceiling/Wall Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Ceiling Tile Installation. . . . . .
Important Safety Instructions 1. Installation and servicing should be done only by qualified service personnel and conform to all local codes. 2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is designed for indoor use only and must not be installed where exposed to rain and moisture. 3. Use only installation methods and materials capable of supporting four times the maximum specified load.
Description The ICS090 Series Camclosure® integrated camera system integrates a camera and lens package in a small, discreet dome. The system is easy to install and can be mounted or recessed to the surface of a ceiling or wall. Prior to the installation of your new system, thoroughly familiarize yourself with the information in this manual.
Remove the Dome Bubble Turn the dome bubble counterclockwise and lift (refer to Figure 1). Place the bubble on a nonabrasive surface. If the unit is supplied with a dome liner, remove the liner before installing the unit. To remove the liner, gently lift it from the unit. Place the liner to the side; it will be reinstalled along with the bubble after the installation has been completed following installation.. Figure 1.
Install the Back Box The installation methods for the ICS090 Series include the following options: • Mount to the surface of a ceiling or wall • Install in a suspended ceiling • Install in a fixed ceiling or wall • Mount to the surface of a 4S standard electrical box • Install in a 4S deep electrical box Select the best method for your installation and refer to the following pages for instructions. INSTALLATION TO SURFACE OF A CEILING/WALL Refer to Figure 2 for the following steps.
4. Use the 6-32 toggle bolts (not supplied) to attach the surface mount ring and back box to the mounting surface, refer to Figure 2. NOTE: For a concrete ceiling/wall installation, use 8-32 mounting hardware (not supplied), refer to Figure 3. Figure 2. Ceiling/Wall Installation Figure 3.
IN-CEILING INSTALLATION: SUSPENDED CEILING Refer to Figure 4 and complete the following steps. 1. Remove the ceiling tile from the ceiling. 2. Cut a 4-inch diameter hole in the ceiling tile. 3. Remove the surface mount ring from the back box. Refer to Figure 5 and complete the following steps: a. Place your fingers on the circular marks located on the sides of the surface mount ring. b. Pinch the sides. c. Lift and remove the surface mount ring from the back box.
STANDOFF BACK BOX SURFACE MOUNT RING Figure 5. How to Remove Surface Mount Ring from Back Box AC operation only: If you are wiring more than one ICS090 Camclosure to the same transformer, connect one side of the transformer to the red wire on all units, and then connect the other side of the transformer to the black wire on all units.
IN-CEILING INSTALLATION: FIXED CEILING/WALL Refer to Figure 6 and complete the following steps. 1. Cut a 4-inch diameter hole in the ceiling/wall. 2. Remove the surface mount ring from the back box. Refer to Figure 5 and complete the following steps: a. Place your fingers on the circular marks located on the sides of the surface mount ring. b. Pinch the sides. c. Lift and remove the surface mount ring from the back box. 3. Connect the video cable/wires.
INSTALLATION TO THE SURFACE OF A 4S STANDARD ELECTRICAL BOX Refer to Figure 7 and complete the following steps. 1. Attach the adapter ring to the 4S box with the two 8-32 x 1.00-inch screws (supplied). 2. Connect the video cable/wires. BNC: Connect the BNC connector from the Camclosure to a mating BNC connector. Twisted pair: Connect the blue wire to Video +; connect the gray wire to Video -. 3. Connect the power wires. Table D.
INSTALLATION IN A 4S DEEP ELECTRICAL BOX Refer to Figure 8 and complete the following steps. 1. Remove the surface mount ring from the back box. Refer to Figure 5 and complete the following steps: a. Place your fingers on the circular marks located on the sides of the surface mount ring. b. Pinch the sides. c. Lift and remove the surface mount ring from the back box. 2. Attach the adapter ring to the 4S box with the two 8-32 x 1.00-inch screws (supplied). 3. Connect the video cable/wires.
Camera Positioning Manually rotate and tilt the camera module to position the camera. Do not over-rotate the module. WARNING: Excessively turning the module in one direction could result in damage to the wiring. ì Tilt 140° î Pan 360° ï Rotation 360° Figure 9.
Camera Adjustments SWITCH SETTINGS SWITCH SETTINGS FOR FIXED FOCAL LENGTH LENS WITHOUT AUTO IRIS Refer to the switch drawing. The switch is located next to the lens. Automatic backlight compensation (factory setting) is used under varying lighting conditions (such as outdoors) or fixed lighting conditions where there are no bright spots that darken other picture details. Manual backlight compensation is used in fixed lighting conditions, to optimize the picture detail when there are bright spots.
VERTICAL PHASE ADJUSTMENT (24 VAC OPERATION ONLY) When using more than one camera power supply, a brief vertical roll may occur on the monitor when a camera view is switched. To eliminate vertical roll, reverse the 24 VAC connections on one camera. If both cameras are connected to the same transformer, this should solve the problem. If reversing the connections does not solve the problem, adjust the phase control by synchronizing, or line-locking, the cameras to one another.
Reinstall the Dome Bubble DOME LINER INSTALLATION If the unit is supplied with a dome liner, reinstall the liner before installing the dome bubble. To install the liner, refer to Figure 11 complete the following steps: 1. Align the studs located on the camera module with the clips on the liner. 2. Lightly pinch the sides of the liner, opposite from the clips, and place the clips over the studs. 3. Once the liner is secure, position the viewing window of the liner over the lens of the camera. 4.
DOME BUBBLE INSTALLATION To install the dome bubble refer to Figure 12 and complete the following steps: 1. Select the bubble (clear or smoked). 2. Align the standoffs of the bubble with the slots of the back box. 3. Turn the bubble clockwise, until it locks in place. Figure 12.
Service Connector An optional 4-foot service/monitor cable, part number ICS090-SC, is available for on-site setup and adjustments. To use the cable simply plug one end of the cable directly into the service connector of the ICS090, and then connect the other end to any standard BNC (VIDEO IN) connector on a monitor. To assemble a longer service cable for the ICS090 Series Camclosure, purchase the following parts at a local electronics supply store: Qty Description 1 2.
Specifications BACKBOX Electrical Input Voltage Power Consumption Video Connector 12 VDC or 24 VAC (±10%), autosensing 3 W or less BNC General Pan/Tilt Adjustment Pan Tilt Rotation Construction Back Box and Surface Mount Ring Bubble Finish Environment Operating Temperature 360° 140° (20° to 160° range) 360° ABS plastic Polycarbonate White Indoor 32° to 120°F (0° to 49°C) Weight Unit Shipping 0.52 lb (0.24 kg) 2.0 lb (0.91 kg) (Design and product specifications subject to change without notice.
The materials used in the manufacture of this document and its components are compliant to the requirements of Directive 2002/95/EC. This equipment contains electrical or electronic components that must be recycled properly to comply with Directive 2002/96/EC of the European Union regarding the disposal of waste electrical and electronic equipment (WEEE). Contact your local dealer for procedures for recycling this equipment.
PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Exceptions to this warranty are as noted below: • • • • • • • • • • • • • • Five years on fiber optic products and TW3000 Series unshielded twisted pair (UTP) transmission products. Three years on Spectra® IV products. Three years on Genex® Series products (multiplexers, server, and keyboard).
Worldwide Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada Tel: 800/289-9100 Fax: 800/289-9150 International Tel: 1-559/292-1981 Fax: 1-559/348-1120 www.pelco.