OPERATION/PROGRAMMING ® Spectra III™ SE Series Models DD53M22 & DD53M22-X C2443M-D (11/05)
OPERATION/PROGRAMMING MANUAL MODELS DD53M22 & DD53M22-X 22X LowLight™ MONOCHROME TECHNOLOGY
C2443M-D (11/05)
CONTENTS WELCOME ................................................................................................................................................................................................ 7 GETTING STARTED .......................................................................................................................................................................... 7 HOW TO OPERATE YOUR DOME SYSTEM ...............................................................................
PRESETS ......................................................................................................................................................................................... 30 PATTERNS ....................................................................................................................................................................................... 32 ZONES .................................................................................................................
WELCOME Thank you for purchasing Pelco’s premier integrated dome system, Spectra III SE. Your new system features a high resolution, monochrome camera with programmable dome drive software. This manual is designed to be a reference tool for the operation and programming of your system. Inside you will find information about Spectra III SE’s features and commands, as well as a detailed menu tree. Getting Started You will need to install your dome system before using this manual.
HOW TO OPERATE YOUR DOME SYSTEM 8 Operation How to Control Pan and Tilt Move joystick or press the direction keys left/right and up/down. Zoom Far To zoom far, do the following: 1. Press the Zoom Tele button or turn the joystick clockwise until zoom stops at the 32X zoom limit. 2. Release the button or joystick for one second. 3. To continue zooming (digitally), press the button or turn the joystick clockwise again until you have the picture you want or reach the digital zoom1 limit.
Accessing Main Menu (Preset 95) You can call up the main menu on your monitor by programming (setting or creating) preset 95 (preset 28 if in AD32-preset mode). Programming preset 95 for Pelco’s controllers varies according to the type of controller you are using. Instructions for programming preset 95 are given below for various Pelco controllers. CM6700/CM6800 1. 2. 3. Enter the number of the Spectra dome system and press the CAM key. Enter 95 and hold the PRESET key for two seconds.
KBD4000/KBD4002 1. 2. Press the SPOT MONITOR key. Enter 95, then hold the PRESET key (approximately five seconds) until the main menu appears on the screen. MPT9500 Standard Coaxitron Mode 1. 2. Enter 95 and press the PRESET SET key. Position the asterisk in the YES row and press the F1 key. The main menu appears. Extended Coaxitron or RS-485 Mode 1. 2. Enter 95 and press the PRESET SET key. Press the F2 key. The main menu appears. NET300/NET350/NET4001A 1. 2. Check the Set box.
QUICK START GUIDE – SYSTEM SETUP SPECTRA III Presets LANGUAGE The following presets are reserved for special functions.
LANGUAGE SPECTRA III LANGUAGE ENGLISH ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT * This setting only applies to Pressurized Spectra III SE dome systems with software version 1.25 or higher. The language for the on-screen menus is selectable. Available languages include English, Spanish, French, German, Italian, Portuguese, Russian, Polish, Turkish, and Czechoslovakian. The factory default language is English.
SYSTEM INFORMATION SPECTRA III LANGUAGE ENGLISH ACK ALERT* The system Information screen displays dome drive model, software version, available memory, and other diagnostic information. System settings cannot be changed using this screen. This screen is for reference only. Use the following steps to display the System Information screen: 1. Use the joystick to position the cursor beside SYSTEM INFORMATION. 2. Press Iris Open.
DISPLAY SETUP SPECTRA III LANGUAGE ENGLISH ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT DISPLAY SETUP PRESET LABEL ZONE LABEL ZOOM AZIMUTH/ELEVATION DIRECTION ALARM MESSAGE 2 (SECS) 2 (SECS) 2 (SECS) 2 (SECS) OFF 2 (SECS)
Label Position SPECTRA III LANGUAGE ENGLISH ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT DISPLAY SETUP PRESET LABEL ZONE LABEL ZOOM AZIMUTH/ELEVATION DIRECTION ALARM MESSAGE 2 (SECS) 2 (SECS) 2 (SECS) 2 (SECS) OFF 2 (SECS)
DOME SETTINGS Camera TYPE OF LIGHTING SPECTRA III LANGUAGE ENGLISH ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT Pelco has calibrated settings that optimize the picture for indoor and outdoor lighting conditions. There are two settings: OUTDOOR (default) INDOOR AUTO FOCUS Auto focus allows the lens to remain in focus during zoom-in, zoom-out, and motion functions.
ZOOM LIMIT SPECTRA III LANGUAGE ENGLISH ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT Zoom limit allows the user to define a limitation on the amount of telephoto zoom. The default setting is 176X. Cameras with 264X zoom (22X optical zoom and 12X digital zoom) can be set for 22X, 32X, 88X, 176X, 220X, or 264X. ZOOM SPEED Zoom Speed allows the user to define how fast the dome will go from full wide zoom to the 22X optical zoom.
Advanced Camera Settings SHUTTER SPEED SPECTRA III LANGUAGE ENGLISH ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT Shutter speed is the duration of the electronic shutter. Program shutter speed to operate automatically (Auto) or manually (Numeric Value).
AUTO IRIS SPECTRA III LANGUAGE ENGLISH ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT Auto iris is the lens function that automatically opens and closes the iris in response to changing light conditions. Program the auto iris to operate automatically or at a user-defined level. OFF Auto iris is disabled, and control is always manual.
AUTO SHARPNESS SPECTRA III Auto sharpness enhances picture detail by increasing the aperture gain of the camera and sharpening the edges in the picture. LANGUAGE ENGLISH ACK ALERT* There are two settings: ON (default) OFF RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT The camera automatically maintains a normal sharpness mode. The sharpness of the picture is set manually by programming the SHARPNESS LEVEL.
BACKLIGHT COMPENSATION (BLC) SPECTRA III LANGUAGE ENGLISH ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT If a bright backlight is present, the subjects in the picture may appear dark or as a silhouette. Backlight compensation enhances objects in the center of the picture. The dome uses the center of the picture to adjust the iris. If there is a bright light source outside of this area, it will wash out to white.
Motion Settings AUTO FLIP SPECTRA III LANGUAGE ENGLISH ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT When the camera tilts downward and goes just beyond the vertical position, the dome rotates 180 degrees. When the dome rotates (flips), the camera starts moving upward as long as you continue to hold the joystick in the down position. Once you let go of the joystick after the dome rotates, joystick control returns to normal operation.
PARK TIME SPECTRA III LANGUAGE ENGLISH ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT This feature allows the dome to begin a specified operation (scan, preset, or pattern) after a programmed time of inactivity. Park time can be programmed from 1 minute to 720 minutes (12 hours), or set to zero, which disables this feature. The default setting is zero. Park Action This feature will define the activity when the dome parks.
SCAN SPEED SPECTRA III LANGUAGE ENGLISH ACK ALERT* Scan speed is the degrees per second that the dome will pan when in a scan mode. Scan speed is adjustable from 1 to 40 degrees per second through the programming menu. The default setting is 25 degrees per second. RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT PRESET FREEZE FRAME This feature freezes the scene on the monitor when going to a preset.
LIMIT STOPS SPECTRA III LANGUAGE ENGLISH ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT Limit stops are programmable stops that limit the pan range of the dome. There must be two limits, a left and a right, to define an area. There are two types of limit stops: MANUAL A manual (joystick) pan operation stops when a limit stop is reached. SCAN The dome reverses direction during random, frame, or auto scanning when a limit stop is reached.
AZIMUTH ZERO SPECTRA III LANGUAGE ENGLISH ACK ALERT* Azimuth is the pan angle from 0° to 359°. Azimuth zero is the pan position you specify to be the 0° point. Azimuth zero is normally set to magnetic north. Once set, azimuth and compass readings are based on the set Azimuth Zero point. RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT To program azimuth zero: 1. Use the joystick to position the cursor beside SET AZIMUTH ZERO. 2. Press Iris Open. 3.
Power Up POWER UP ACTION SPECTRA III LANGUAGE ENGLISH ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT DOME SETTINGS * BACK EXIT This setting defines a specific activity (scan, preset, pattern) to be performed in the event the power to the dome is cycled.
Line Sync SPECTRA III LANGUAGE ENGLISH ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT Line sync refers to a programmable function that allows you to synchronize all cameras within a matrix system. NOTE: Spectra III SE automatically senses V-sync input. No line sync setup is required for Pelco control systems that provide a V-sync signal.
Presets SPECTRA III LANGUAGE ENGLISH ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT 83-89 90-91 92-93 94 95 96 97 98 99 DOME SETTINGS 1 2. BACK EXIT Edit the preset label: a. Use the joystick to position the cursor beside EDIT PRESET LABEL. b. Press Iris Open.
SPECTRA III 3. Edit the preset scene: a. Use the joystick to position the cursor beside EDIT PRESET SCENE. b. Press Iris Open. c. Follow the directions displayed on the monitor. 4. Edit preset camera settings: a. Use the joystick to position the cursor beside EDIT CAMERA SETTINGS. b. Press Iris Open. The EDIT CAMERA SETTINGS window appears on the monitor. Refer to the Camera and Advanced Camera Settings sections of this manual to change preset camera settings.
Patterns SPECTRA III LANGUAGE ENGLISH ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT The Spectra III SE can handle up to four user-defined patterns. Pattern length is based upon memory usage rather than a fixed amount of time. The complexity of a pattern will determine the amount of storage available to program other patterns. To program a pattern: 1. Use the joystick to position the cursor beside PATTERN NUMBER. Press Iris Open.
Zones SPECTRA III LANGUAGE ENGLISH ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT A zone is a pan area, defined by a left and right limit, on the 360-degree pan plane. The Spectra dome system is capable of eight zones, each with a 20-character label. To program a zone: 1. Use the joystick to position the cursor beside ZONE NUMBER. Press Iris Open the cursor moves to the right. 2. Move the joystick up or down to view selections.
Window Blanking SPECTRA III LANGUAGE ENGLISH ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT Window blanking allows a user to program up to eight, four-sided, user-defined areas that cannot be viewed by the operator of the dome system. A blanked area will move with pan and tilt functions and automatically adjust in size as the lens zooms telephoto and wide. Spectra III SE has two style modes for window blanking, GRAY and SMEAR.
6. SPECTRA III LANGUAGE ENGLISH ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT The blanked area can be programmed to turn on or off at a specified zoom point. To set the zoom point: a. Use the joystick to position the cursor beside EDIT WINDOW ZOOM, and then pres Iris Open. b. Zoom in to the point where you want window blanking to turn on. Press Iris Open to set the zoom point.
REVERSE A blanked out area can be reversed to make it visible and the areas on both sides of it not visible. The areas above and below the blanking area remain visible. Reversing the window a second time will return it to its original condition. CLEAR WINDOW All areas that have been set for window blanking are cleared. BLANK ALL ABOVE/BLANK ALL BELOW Blank All Above and Blank All Below add additional flexibility to setting up privacy areas.
Alarms The Spectra III SE dome has seven alarm inputs, which can be programmed as high, medium or low priority. When an alarm is received, an input signal to the dome triggers the user-defined action (go to preset, run pattern, etc.) programmed for the alarm.
SPECTRA III 3. Select the alarm priority: a. Use the joystick to position the cursor beside ALARM PRIORITY. b. Press Iris Open. The cursor moves to the right. c. Move the joystick up or down to view the available selections. Available settings include HIGH, MEDIUM, and LOW (default). If multiple alarms with different priorities are active at the same time, the dome will only go to the alarms with the highest priority. d. Press Iris Open to enter selection.
5. SPECTRA III LANGUAGE ENGLISH ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT Set the auxiliary to activate: a. Use the joystick to position the cursor beside ACTIVATE AUX. b. Press Iris Open. The cursor moves to the right. c. Move the joystick up or down to view the following available selections. NO (default) Not activated. 1 An alarm action will close AUX 1. 2 An alarm action will close AUX 2. d. Press Iris Open to enter selection.
Aux SPECTRA III LANGUAGE ENGLISH ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT An auxiliary output is a programmable signal from the dome back box that can trigger another device to operate. An auxiliary output is programmable to trigger from an alarm or from a controller. An AUX 1 command from the controller will activate the relay in the dome and operate the device that is connected to the relay.
Title Text SPECTRA III LANGUAGE ENGLISH ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT Title text is the label used to identify the camera viewed on the monitor. Up to 20 characters can be used for a title. To edit the title text label, do the following: 1. Use the joystick to position the cursor beside EDIT TITLE TEXT. 2. Press Iris Open.
Alert SPECTRA III LANGUAGE ENGLISH ACK ALERT RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT NOTE: The Alert section only applies to Pressurized Spectra III SE dome systems with software version 1.25 or higher. Spectra III SE systems that are not pressurized or pressurized systems that do not have dome drive software version 1.25 or higher will not display this menu item. Software version 1.
ACK ACTION SPECTRA III LANGUAGE ENGLISH ACK ALERT RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT ACTIVATE AUX DOME SETTINGS BACK EXIT This setting activates an auxiliary when an alert condition exists. ACTIVATE AUX settings include the following: NO (default) Not activated.
Clear SPECTRA III LANGUAGE ENGLISH ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT DOME SETTINGS * BACK EXIT Use this setting to clear user-defined settings or return the dome to factory default settings. The following are the available CLEAR settings: ALL ZONES Clears all zones.
Password SPECTRA III LANGUAGE ENGLISH ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT Spectra III SE features password protection to prevent unauthorized changes to the dome settings. An operator can open the System Information and Display Setup Screens, but cannot access any of the Dome Settings menus. Controller/keyboard commands cannot override password-protected settings.
RESET, CYCLE POWER, REBOOT RESET CAMERA SPECTRA III LANGUAGE ENGLISH ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT * This setting only applies to Pressurized Spectra III SE dome systems with software version 1.25 or higher. 46 Use this function to reset all camera settings to factory default parameters. CYCLE CAMERA POWER If the camera is not operating or if you lose camera control, cycle camera power.
SOFTWARE/LANGUAGE FILE UPLOAD The RJ-45 data port of the dome drive allows access for on-site setup, testing, and uploading of revised operating software and language files. A Pelco field service tool is required to perform these operations. Field service tools include Pelco’s remote monitor kit (IPS-RMK), remote data port box (IPS-RDPE-2), and remote monitor cable (IPS-CABLE).
SPECIFICATIONS DD53M22 Signal Format NTSC Scanning System 2:1 Interlace Image Sensor 1/4-inch CCD Effective Pixels 768 (H) X 494 (V) Horizontal Resolution >500 TV lines Lens F1.6 (f=4~88 mm optical, 22X optical zoom, 12X digital zoom) Zoom Speed (optical range) 2.4/3.9/6.3 seconds Horizontal Angle of View 47° at 4 mm wide zoom; 2.2° at 88 mm telephoto zoom Focus Automatic with manual override Maximum Sensitivity at 35 IRE 0.005 lux at 1/2 sec.
REGULATORY NOTICES This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. RADIO AND TELEVISION INTERFERENCE This equipment has been tested and found to comply with the limits of a Class B digital device, pursuant to part 15 of the FCC rules.