INSTALLATION/OPERATION Spectra® IV and Spectra® IV SE Series Dome Drives C3412M (9/06)
Contents Welcome. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Switch Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dome Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Camera. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Type of Lighting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Aux . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 Edit Schedule . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 Title Text . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Welcome Thank you for purchasing Pelco’s premier integrated dome system, Spectra® IV/Spectra® IV SE. Your new system features a high resolution camera/optics package with programmable dome drive software. This manual is designed primarily to be a reference tool for the operation and programming of your system. Inside you will find information about features and commands, as well as a detailed menu tree and a quick start guide.
Installation NOTE: This manual contains installation instructions only for the Spectra IV/Spectra IV SE dome drive. For complete installation instructions for a Spectra IV/Spectra IV SE dome system, refer to the installation manual shipped with the back box. SWITCH SETTINGS Before installing the dome drive, configure the receiver address, termination, and baud setting. The DIP switches used to configure these settings are located on the base of the dome drive.
CM9502 Setting If a CM9502 matrix system is used with the dome drive, set SW2-2 to the ON position. Vicon System The Vicon protocol is not currently available. SW2-3 is reserved for future use. SW2 SWITCHES 4-5 – SERIAL PORT SETTINGS 2 Wire Setting (RS-485) SW2-4 should be set to the ON position if a two-wire serial port connection is used. 4 Wire Setting (RS-422) SW2-5 should be set to the ON position if a four-wire serial port connection is used.
DOME DRIVE INSTALLATION Install the dome drive. Line up the blue and red tabs with the blue and red arrows on the hinged door inside the back box. Push the tabs in. Insert one side and then the other side. Continue pushing on the ends of the tabs until both sides click into place. Refer to Figure 2. To use your dome system, refer to the Getting Started section. Figure 2.
Table A.
Table B.
Table B.
Table B.
Table B.
Table B.
Table B.
Table B.
Table B.
Getting Started Once installed, apply power to the Spectra IV/Spectra IV SE dome system. The system will start a configuration sequence. When configuration is done, the following information is displayed: Pelco Spectra IV/Spectra IV SE Version X.XX D Address: 1 P Address: 2 Comm 2400, N, 8, 1 CONFIGURE DONE This information will remain on the monitor until dome operation begins. Refer to the following pages to learn how to operate and program your dome system.
How to Operate Your Dome System Operation How to Control Pan and Tilt Move joystick or press the direction keys left/right and up/down. Zoom Far To zoom far, do the following: 1. Press the Zoom Tele button or turn the joystick clockwise until zoom stops at the 32X zoom limit. 2. Release the button or joystick for one second. 3. To continue zooming (digitally), press the button or turn the joystick clockwise again until you have the picture you want or reach the digital zoom1 limit.
QUICK PROGRAMMING GUIDE Access main menu (preset 95). See the Accessing Main Menu (Preset 95) section. Use the joystick to position the cursor beside menu selection. NOTE: If your controller does not have a joystick, use the up or down key. Press Iris Open, the submenu/cursor moves to the right. Move the joystick up or down to view selections. Press Iris Open to make selection. Press Iris Close to cancel selection.
CM9500 1. Enter the number of the Spectra IV/Spectra IV SE dome system and press the CAM key. The main menu appears. 2. Highlight SETUP in the main menu and press the SELECT key. 3. Highlight CAM in the Setup menu and press the SELECT key. 4. Highlight PRESET in the Camera menu and press the SELECT key. 5. Enter 95 and press the F1 key. The main menu appears. CM9740/CM9760/CM9770/CM9780 1. Press the ESCAPE key to open the main menu. Select DEF. The Define submenu appears. 2.
NET300/NET350/NET4001A 1. Check the Set box. 2. Click the preset 95 button. The main menu appears. WS5050 1. Right-click in the video pane of the Spectra IV/Spectra IV SE dome system. 2. Click Preset and then click Select Preset. 3. Enter 95 and then click OK. VCD5000 1. Enter 95 for the preset action. The shortcuts menu appears. 2. Press the Preset button on the KBD5000.
16X LowLight Color Menu Tree SPECTRA IV LANGUAGE ACK ALERT* ENGLISH RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM SYSTEM INFORMATION SERIAL # DOME DRIVE MODEL BACK BOX MEMORY SOFTWARE VERSION FONT VERSION FONT VERSION COMM D ADDRESS P ADDRESS CM9500 MODE 32 PRESETS PROTOCOL PRESSURIZED* DISPLAY SETUP XXXXXXXXXXXXXX XX-XXXX AVAILABLE XX.X XX.X XX.X XXXXXXXXXX 1 2 OFF OFF C X.
DOME SETTINGS * PRESETS LINE SYNC LINE SYNC LINE SYNC PHASE ON 0 TOGGLE 1 TOGGLE 1 EDIT THE PASSWORD 1234567890 ABCDEFGHIJ KLMNOPQRST UVWXY.
22X EXview LowLight Black-White Menu Tree SPECTRA IV LANGUAGE ACK ALERT* ENGLISH RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM SYSTEM INFORMATION SERIAL # DOME DRIVE MODEL BACK BOX MEMORY SOFTWARE VERSION FONT VERSION FONT VERSION COMM D ADDRESS P ADDRESS CM9500 MODE 32 PRESETS PROTOCOL PRESSURIZED* DISPLAY SETUP XXXXXXXXXXXXXX XX-XXXX AVAILABLE XX.X XX.X XX.X XXXXXXXXXX 1 2 OFF OFF C X.
DOME SETTINGS * LINE SYNC LINE SYNC LINE SYNC PHASE PRESETS ON 0 ALARMS RESUME SEQUENCE (SECS) RESET DELAY (SECS) ALARM CONTACT EDIT THE PASSWORD 1234567890 ABCDEFGHIJ KLMNOPQRST UVWXY.
22X EXview LowLight Color Menu Tree SPECTRA IV LANGUAGE ACK ALERT* ENGLISH RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM SYSTEM INFORMATION SERIAL # DOME DRIVE MODEL BACK BOX MEMORY SOFTWARE VERSION FONT VERSION FONT VERSION COMM D ADDRESS P ADDRESS CM9500 MODE 32 PRESETS PROTOCOL PRESSURIZED* DISPLAY SETUP XXXXXXXXXXXXXX XX-XXXX AVAILABLE XX.X XX.X XX.X XXXXXXXXXX 1 2 OFF OFF C X.
DOME SETTINGS * PRESETS LINE SYNC LINE SYNC LINE SYNC PHASE ON 0 EDIT THE PASSWORD 1234567890 ABCDEFGHIJ KLMNOPQRST UVWXY.
23X LowLight Day/Night Menu Tree SPECTRA IV LANGUAGE ACK ALERT* ENGLISH RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM SYSTEM INFORMATION SERIAL # DOME DRIVE MODEL BACK BOX MEMORY SOFTWARE VERSION FONT VERSION FONT VERSION COMM D ADDRESS P ADDRESS CM9500 MODE 32 PRESETS PROTOCOL PRESSURIZED* DISPLAY SETUP XXXXXXXXXXXXXX XX-XXXX AVAILABLE XX.X XX.X XX.X XXXXXXXXXX 1 2 OFF OFF C X.
DOME SETTINGS * LINE SYNC LINE SYNC LINE SYNC PHASE ALARMS ALARM CONTACT EDIT THE PASSWORD 1234567890 ABCDEFGHIJ KLMNOPQRST UVWXY.
35X LowLight Day/Night Menu Tree SPECTRA IV LANGUAGE ACK ALERT* ENGLISH RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM SYSTEM INFORMATION SERIAL # DOME DRIVE MODEL BACK BOX MEMORY SOFTWARE VERSION FONT VERSION FONT VERSION COMM D ADDRESS P ADDRESS CM9500 MODE 32 PRESETS PROTOCOL PRESSURIZED* DISPLAY SETUP XXXXXXXXXXXXXX XX-XXXX AVAILABLE XX.X XX.X XX.X XXXXXXXXXX 1 2 OFF OFF C X.
DOME SETTINGS * LINE SYNC LINE SYNC LINE SYNC PHASE ALARMS RESUME SEQUENCE (SECS) RESET DELAY (SECS) ALARM CONTACT EDIT THE PASSWORD 1234567890 ABCDEFGHIJ KLMNOPQRST UVWXY.
Language SPECTRA IV LANGUAGE ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT The language for the on-screen menus is selectable. Available languages include English, Spanish, French, German, Italian, Portuguese, Russian, Polish, Turkish, and Czechoslovakian. The factory default language is English. To change the display language: 1. Use the joystick to position the cursor beside LANGUAGE. 2. Press Iris Open.
System Information SPECTRA IV LANGUAGE ACK ALERT* The System Information screen displays dome drive model, software version, available memory, and other diagnostic information. System settings cannot be changed using this screen. This screen is for reference only. Use the following steps to display the System Information screen: RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM 1. Use the joystick to position the cursor beside SYSTEM INFORMATION.
Display Setup SPECTRA IV LANGUAGE ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT DISPLAY SETUP PRESET LABEL ZONE LABEL ZOOM AZIMUTH/ELEVATION DIRECTION ALARM MESSAGE DATE/TIME
LABEL POSITIONS SPECTRA IV LANGUAGE ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT Labels can be placed anywhere on the monitor. This feature allows you to customize the appearance of your monitor screen. The following labels are not set at fixed positions: PRESET LABEL ZONE LABEL ALARM 1 ZOOM RATIO - XXX.
Dome Settings CAMERA SPECTRA IV LANGUAGE TYPE OF LIGHTING (Does not apply to 16X or 23X models.) ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT Pelco has calibrated settings that optimize the white balance and the picture for indoor and outdoor lighting conditions. There are two settings: OUTDOOR (default) INDOOR AUTO FOCUS Auto focus allows the lens to remain in focus during zoom-in, zoom-out, and motion functions.
SPECTRA IV LANGUAGE ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT ZOOM LIMIT Zoom limit allows the user to define a limitation on the amount of telephoto zoom. The settings vary depending on camera model. 16X (Models DD4TC16 and DD4TC16-X) The default setting is 32X. Cameras with 128X zoom (16X optical zoom and 8X digital zoom) can be set for 16X, 32X, 64X, or 128X.
SPECTRA IV LANGUAGE ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT ZOOM SPEED Zoom speed allows the user to define how fast the dome will go from full wide zoom to the 16X, 22X, 23X, or 35X optical zoom. Available zoom speed settings for 16X models include the following: HIGH 1.9 seconds MEDIUM (default) 3.6 seconds LOW 6.
SPECTRA IV LANGUAGE IR CUT FILTER (Applies only to 23X and 35X models.) ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT DOME SETTINGS * BACK EXIT CAMERA The 23X and 35X cameras have two modes of operation: color, and black-white.
ADVANCED CAMERA SETTINGS SPECTRA IV LANGUAGE ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM SHUTTER SPEED Shutter speed is the duration of the electronic shutter. Program shutter speed to operate automatically (Auto) or manually (Numeric Value). AUTO (default) The electronic shutter speed is set automatically by the amount of light sensed by the camera.
SPECTRA IV LANGUAGE ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT DOME SETTINGS * BACK EXIT CAMERA AUTO IRIS Auto iris is the lens function that automatically opens and closes the iris in response to changing light conditions.
SPECTRA IV LANGUAGE ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT DOME SETTINGS * BACK EXIT AUTO SHARPNESS Auto sharpness enhances picture detail by increasing the aperture gain of the camera and sharpening the edges in the picture.
SPECTRA IV LANGUAGE ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM BACKLIGHT COMPENSATION (BLC) If a bright backlight is present, the subjects in the picture may appear dark or as a silhouette. Backlight compensation enhances objects in the center of the picture. The dome uses the center of the picture to adjust the iris. If there is a bright light source outside of this area, it will wash out to white.
SPECTRA IV LANGUAGE VIDEO LEVEL Set the video output to one of the following: ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM NORMAL 1.0 volt peak-to-peak HIGH (default setting) 1.2 volt peak-to-peak to compensate for losses in video cable. WIDE DYNAMIC RANGE EXIT (Applies only to 23X and 35X models.
SPECTRA IV LANGUAGE ELECTRONIC IMAGE STABILIZATION (Applies only to 35X models.) ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT DOME SETTINGS * BACK EXIT Electronic image stabilization is a feature of the camera that can compensate for some forms of external influences.
MOTION SETTINGS SPECTRA IV LANGUAGE ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM AUTO FLIP When the camera tilts downward and goes just beyond the vertical position, the dome rotates 180 degrees. When the dome rotates (flips), the camera starts moving upward as long as you continue to hold the joystick in the down position. Once you let go of the joystick after the dome rotates, joystick control returns to normal operation.
SPECTRA IV LANGUAGE ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM PARK TIME This feature allows the dome to begin a specified operation (scan, preset, or pattern) after a programmed time of inactivity. Park time can be programmed from 1 minute to 720 minutes (12 hours), or set to zero, which disables this feature. The default setting is zero. Park Action EXIT This feature will define the activity when the dome parks.
SPECTRA IV LANGUAGE ACK ALERT* SCAN SPEED Scan speed is the degrees per second that the dome will pan when in a scan mode. Scan speed is adjustable from 1 to 40 degrees per second through the programming menu. The default setting is 25 degrees per second. RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM PRESET FREEZE FRAME EXIT This feature freezes the scene on the monitor when going to a preset.
SPECTRA IV LANGUAGE ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT LIMIT STOPS Limit stops are programmable stops that limit the pan range of the dome. There must be two limits, a left and a right, to define an area. There are two types of limit stops: MANUAL A manual (joystick) pan operation stops when a limit stop is reached. SCAN The dome reverses direction during random, frame, or auto scanning when a limit stop is reached.
SPECTRA IV LANGUAGE ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT AZIMUTH ZERO Azimuth is the pan angle from 0° to 359°. Azimuth zero is the pan position you specify to be the 0° point. Azimuth zero is normally set to magnetic north. Once set, azimuth and compass readings are based on the set Azimuth Zero point. To program azimuth zero: 1. Use the joystick to position the cursor beside SET AZIMUTH ZERO. 2. Press Iris Open. 3.
POWER UP SPECTRA IV LANGUAGE ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT DOME SETTINGS * BACK EXIT POWER UP POWER UP ACTION BACK EXIT POWER UP ACTION This setting defines a specific activity (scan, preset, pattern) to be performed in the event the power to the dome is cycled.
LINE SYNC SPECTRA IV LANGUAGE Line sync refers to a programmable function that allows you to synchronize all cameras within a matrix system. ACK ALERT* NOTE: Spectra IV and Spectra IV SE dome systems automatically sense V-Sync input. No line sync setup is required for Pelco control systems that provide a V-Sync signal.
PRESETS NOTE: The number of programmable presets available is limited by the model of the back box you are using. If you are using an older model back box, you may not have access to all of the available presets. Refer to the table below for a list of back boxes and the presets available for each.
NOTE: For American Dynamics controllers with only 32 presets, switch SW2-1 on the dome drive to the ON position. When SW2-1 is ON, preset 99 becomes 32 92 becomes 25 98 becomes 31 91 becomes 24 97 becomes 30 90 becomes 23 96 becomes 29 89 becomes 22 95 becomes 28 88 becomes 21 93 becomes 26 SPECTRA IV LANGUAGE ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT If the limit stops are turned off, presets 23-26 can be used as regular presets.
4. Edit preset camera settings: SPECTRA IV LANGUAGE a. Use the joystick to position the cursor beside EDIT CAMERA SETTINGS. ACK ALERT* b. Press Iris Open. The EDIT CAMERA SETTINGS window appears on the monitor. Refer to the Camera and Advanced Camera Settings sections of this manual to change preset camera settings. RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM c.
SPECTRA IV LANGUAGE ENABLE MOTION DETECTION (Applies only to 23X and 35X models.) ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM The following are the settings for motion detection: OFF (default) Motion detection is turned off (disabled). ON Motion detection is turned on (enabled). NOTE: Motion detection does not work if the shutter speed is set at less than 1/60 of a second.
EDIT DETECTION AREAS DETECTION AREA 1 LOCATION SENSITIVITY DETECTION AREA 2 LOCATION SENSITIVITY DETECTION AREA 3 LOCATION SENSITIVITY DETECTION AREA 4 LOCATION SENSITIVITY BACK EXIT 0 MEDIUM 0 MEDIUM 0 MEDIUM 0 MEDIUM MOTION DETECTION AREAS NOTE: Motion detection is not guaranteed to catch 100% of activity.
SPECTRA IV LANGUAGE ACTIVATE AUX COMMAND (Applies only to 23X and 35X models.) ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT DOME SETTINGS * BACK EXIT PRESETS Motion detection can be programmed to trigger an auxiliary command when motion is detected.
PATTERNS SPECTRA IV LANGUAGE ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM A pattern is a memorized, repeating series of pan, tilt, zoom, and preset functions that can be recalled with a command from a controller or automatically by a programmed function (alarm, park, event, or power-up). Both 16X and 23X models have one user-defined pattern available. The 22X and 35X models can handle up to eight patterns.
ZONES SPECTRA IV LANGUAGE ACK ALERT* A zone is a pan area, defined by a left and right limit, on the 360-degree pan plane. The Spectra 4 and Spectra IV SE dome systems are capable of eight zones, each with a 20-character label. To program a zone: 1. Use the joystick to position the cursor beside ZONE NUMBER. Press Iris Open, and the cursor moves to the right. RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM 2.
WINDOW BLANKING SPECTRA IV LANGUAGE ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT DOME SETTINGS * BACK EXIT WINDOW BLANKING STYLE Window blanking allows a user to program four-sided areas that cannot be viewed by the operator of the dome system.
SPECTRA IV LANGUAGE 6. The blanked area can be programmed to turn on or off at a specified zoom point. To set the zoom point: a. Use the joystick to position the cursor beside EDIT WINDOW ZOOM, and then press Iris Open. ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT b. Zoom in to the point where you want window blanking to turn on. Press Iris Open to set the zoom point.
BLANK ALL ABOVE/BLANK ALL BELOW The Blank All Above and Blank All Below options add additional flexibility to setting up privacy areas. These settings are ideal for applications where a complete pan location needs to be blanked. Blank All Above Blank All Below Blanks everything above a user-defined tilt angle. A blanked band will appear at the top of the screen. The following settings are available: Blanks everything below a user-defined tilt angle. A blanked circle will appear below the specified angle.
ALARMS SPECTRA IV LANGUAGE ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT The Spectra IV SE dome systems have seven alarm inputs that can be programmed as high, medium, or low priority. When an alarm is received, an input signal to the dome triggers the userdefined action (go to preset, run pattern, etc.) programmed for the alarm. NOTE: Refer to the notation in step 6 for the limited alarm features available for 16X and 23X models.
SPECTRA IV LANGUAGE ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT DOME SETTINGS * BACK EXIT 3. Select the alarm priority: a. Use the joystick to position the cursor beside ALARM PRIORITY. b. Press Iris Open. The cursor moves to the right. c.
SPECTRA IV LANGUAGE ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT 5. Set the auxiliary to activate: a. Use the joystick to position the cursor beside ACTIVATE AUX. b. Press Iris Open. The cursor moves to the right. c. Move the joystick up or down to view the following available selections. NO (default) Not activated. 1 An alarm action will close AUX 1. 2 An alarm action will close AUX 2.
AUX NOTE: The auxiliary feature is functional and available for 16X and 23X models only if the dome drive is installed in a Spectra III SE or Spectra IV SE back box. SPECTRA IV LANGUAGE ACK ALERT* An auxiliary output is a programmable signal from the dome back box that can trigger another device to operate. An auxiliary output is programmable to trigger from an alarm or from a controller.
TITLE TEXT SPECTRA IV LANGUAGE ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM Title text is the label used to identify the camera viewed on the monitor. Up to 20 characters can be used for a title. To edit the title text label, do the following: 1. Use the joystick to position the cursor beside EDIT TITLE TEXT. 2. Press Iris Open. The following appears on the monitor: EXIT EDIT TITLE TEXT 1234567890 ABCDEFGHIJ KLMNOPQRST UVWXY.
ALERT SPECTRA IV LANGUAGE ACK ALERT RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM NOTE: The Alert option applies only to Pressurized Spectra IV dome systems. Spectra 4 systems that are not pressurized will not display this menu item. Sensors strategically placed inside the pressurized dome system continually monitor pressure, temperature, and dew point.
SPECTRA IV LANGUAGE ACK ALERT RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT ACK ACTION Acknowledge action programs the alert label behavior after the alert condition has been acknowledged. The following settings are available for acknowlegde: ALWAYS ON The alert label is displayed until alert conditions are cleared. OFF 8 HRS The alert label is turned off for 8 hours. Label returns after 8 hours if the alert condition persists.
CLEAR SPECTRA IV LANGUAGE Use this setting to clear user-defined settings or return the dome to factory default settings. The following are the available settings: ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT DOME SETTINGS * BACK EXIT ALL ZONES Clears all zones.
PASSWORD Spectra IV and Spectra IV SE feature password protection to prevent unauthorized changes to the dome settings. An operator can open the System Information and Display Setup screens, but cannot access any of the dome settings menus. SPECTRA IV LANGUAGE ACK ALERT* Controller/keyboard commands cannot override password-protected settings. If a keyboard is used to set a preset, pattern, or zone, the Enter Password screen appears on the monitor.
CLOCK SPECTRA IV LANGUAGE ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT The clock is used to program the current date and time. The date and time set in the Clock menu is used to program events. The date and time can also be displayed on the monitor when the menus are not being accessed. To program the clock, do the following: 1. Use the joystick to position the cursor beside TIME BASE. Press Iris Open.
7. If FIXED DATE was selected, the following appears on the monitor: CLOCK TIME BASE TIME FORMAT SET TIME INTERNAL CLOCK 12 HOUR 00:00 AM DATE FORMAT SET DATE MM/DD/YYYY 00/00/0000 DAYLIGHT SAVINGS TIME SHIFT START DATE MONTH DAY START TIME END DATE MONTH DAY END TIME FIXED DATE 1 HOUR APRIL 1 02:00 AM OCTOBER 1 02:00 AM BACK EXIT a. Use the joystick to position the cursor beside TIME SHIFT. Press Iris Open. Scroll through the options until the desired selection appears.
8. If RELATIVE DATE was selected, the following appears on the monitor: CLOCK TIME BASE TIME FORMAT SET TIME INTERNAL CLOCK 12 HOUR 00:00 AM DATE FORMAT SET DATE MM/DD/YYYY 00/00/0000 DAYLIGHT SAVINGS RELATIVE DATE TIME SHIFT 1 HOUR START DATE MONTH APRIL WEEK 1ST DAY SUNDAY START TIME 02:00 AM END DATE MONTH WEEK DAY END TIME OCTOBER LAST SUNDAY 02:00 AM BACK EXIT Follow the instructions in step 7 for FIXED DATE, adding WEEK.
EVENT SPECTRA IV LANGUAGE ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT An event is a preprogrammed camera, park, scan, preset, pattern, window blanking, alarm, or auxiliary function that can be performed automatically at a specific date and time. For example, suppose a camera is set to run in a continuous pattern that scans a parking lot during business hours Monday through Friday.
SPECTRA IV LANGUAGE EDIT EVENT LABEL Use the following steps to edit the event label. ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM 1. Use the joystick to position the cursor beside EDIT EVENT LABEL. 2. Press Iris Open.
SPECTRA IV LANGUAGE EDIT EVENT Use the following steps to edit an event. ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM 1. Use the joystick to position the cursor beside EDIT EVENT. 2. Press Iris Open.
SPECTRA IV LANGUAGE CLEAR EVENT To clear an event: ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM 1. Use the joystick to position the cursor beside CLEAR EVENT. 2. Press Iris Open. 3. Follow the directions displayed on the monitor.
SPECTRA IV LANGUAGE EDIT HOLIDAY Use the following steps to edit a holiday: ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT 1. Use the joystick to position the cursor beside EDIT EVENT LABEL. 2. Press Iris Open. 3. Use the joystick to position the cursor beside OCCURRENCE. Press Iris Open.
SPECTRA IV LANGUAGE CLEAR HOLIDAY To clear a holiday: ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM 1. Use the joystick to position the cursor beside CLEAR HOLIDAY. 2. Press Iris Open. 3. Follow the directions displayed on the monitor.
SCHEDULED EVENTS Use this page to record scheduled events. EVENT NUMBER EVENT TYPE LABEL TIME OCCURS HOLIDAY Example: 1 Preset Weekend 11:00 AM Sat-Sun Skips Holidays Description: Camera focuses on gate on weekends when the office is closed.
Reset, Cycle Power, Reboot RESET CAMERA SPECTRA IV LANGUAGE ENGLISH Use this function to reset all camera settings to factory default parameters. ACK ALERT* CYCLE CAMERA POWER RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM If the camera is not operating or if you lose camera control, cycle camera power. Cycling camera power resets the camera but does not change any saved camera settings.
Software/Language File Upload The RJ-45 data port of the dome drive allows access for on-site setup, testing, and uploading of revised operating software and language files. A Pelco field service tool is required to perform these operations. Field service tools include Pelco’s remote monitor kit (IPS-RMK), remote data port box (IPS-RDPE-2), and remote monitor cable (IPS-CABLE).
Suggested Preventative Maintenance The Spectra IV and Spectra IV SE dome systems do not require any special maintenance. Occasionally, dust may build up on the inside or the outside of the dome. If this occurs, turn power to the unit off and remove the lower dome from the back box. Remove the dust from the lower dome using compressed air from a spray can. Replace the lower dome following the installation instructions that were shipped with it.
Specifications 16X MODELS DD4TC16 Signal Format Scanning System Image Sensor Effective Pixels Horizontal Resolution Lens Zoom Speed (optical range) Horizontal Angle of View Focus Maximum Sensitivity at 35 IRE Sync System Shutter Speed Iris Control Gain Control Video Output Video Signal to Noise NTSC 2:1 Interlace 1/4-inch interline transfer CCD 768 (H) X 494 (V) >470 TV lines F1.4 (f=4~64 mm optical, 16X optical zoom, 8X digital zoom) 1.9/3.6/6.
22X MODELS (MONOCHROME) DD4M22 Signal Format Scanning System Image Sensor Effective Pixels Horizontal Resolution Lens Zoom Speed (optical range) Horizontal Angle of View Focus Maximum Sensitivity at 35 IRE Sync System Shutter Speed Iris Control Gain Control Video Output Video Signal to Noise NTSC 2:1 Interlace 1/4-inch CCD 724 (H) X 494 (V) >500 TV lines F1.6 (f=4~88 mm optical, 22X optical zoom, 12X digital zoom) 2.4/3.9/6.3 seconds 47° at 4 mm wide zoom; 2.
22X MODELS (COLOR) DD4C22 Signal Format Scanning System Image Sensor Effective Pixels Horizontal Resolution Lens Zoom Speed (optical range) Horizontal Angle of View Focus Maximum Sensitivity at 35 IRE Sync System White Balance Shutter Speed Iris Control Gain Control Video Output Video Signal to Noise NTSC 2:1 Interlace 1/4-inch CCD 724 (H) X 494 (V) >470 TV lines F1.6 (f=4~88 mm optical, 22X optical zoom, 12X digital zoom) 2.4/3.9/6.3 seconds 47° at 4 mm wide zoom; 2.
23X MODELS DD4CBW23 Signal Format Scanning System Image Sensor Effective Pixels Horizontal Resolution Lens Zoom Speed (optical range) Horizontal Angle of View Focus Maximum Sensitivity at 35 IRE Sync System White Balance Shutter Speed Iris Control Gain Control Video Output Video Signal to Noise Wide Dynamic Range C3412M (9/06) NTSC 2:1 Interlace 1/4-inch CCD 724 (H) X 494 (V) >470 TV lines F1.6 (f=3.6~82.8 mm optical, 23X optical zoom, 12X digital zoom) 2.9/4.2/5.8 seconds 54° at 3.6 mm wide zoom; 2.
DD4CBW23-X Signal Format Scanning System Image Sensor Effective Pixels Horizontal Resolution Lens Zoom Speed Horizontal Angle of View Focus Maximum Sensitivity at 35 IRE Sync System White Balance Shutter Speed Iris Control Gain Control Video Output Video Signal to Noise Wide Dynamic Range 92 PAL 2:1 Interlace 1/4-inch CCD 724 (H) X 582 (V) >470 TV lines F1.6 (f=3.6~82.8 mm optical, 23X optical zoom, 12X digital zoom) 2.9/4.2/5.8 seconds 54° at 3.6 mm wide zoom; 2.5° at 82.
35X MODELS DD4CBW35 Signal Format Scanning System Image Sensor Effective Pixels Horizontal Resolution Lens Zoom Speed (optical range) Horizontal Angle of View Focus Maximum Sensitivity at 35 IRE Sync System White Balance Shutter Speed Iris Control Gain Control Video Output Video Signal to Noise Wide Dynamic Range C3412M (9/06) NTSC 2:1 Interlace 1/4-inch CCD 768 (H) X 494 (V) >540 TV lines F1.4 (f=3.4~119 mm optical, 35X optical zoom, 12X digital zoom) 3.2/4.6/6.6 seconds 55.8° at 4.2 mm wide zoom; 1.
DD4CBW35-X Signal Format Scanning System Image Sensor Effective Pixels Horizontal Resolution Lens Zoom Speed Horizontal Angle of View Focus Maximum Sensitivity at 35 IRE Sync System White Balance Shutter Speed Iris Control Gain Control Video Output Video Signal to Noise Wide Dynamic Range PAL 2:1 Interlace 1/4-inch CCD 724 (H) X 582 (V) >540 TV lines F1.4 (f=3.4~119 mm optical, 35X optical zoom, 12X digital zoom) 3.2/4.6/6.6 seconds 55.8° at 4.2 mm wide zoom; 1.
PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or (559) 292-1981 to obtain a Repair Authorization number (RA), and provide the following information: Exceptions to this warranty are as noted below: 1. Model and serial number 2. Date of shipment, P.O.