INSTALLATION/OPERATION Spectra IV SL and Spectra IV SE Series ® 23X, 27X, and 35X Dome Drives C3463M-B (2/11)
Contents Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Switch Settings. . . . . . . . . . . . . . . .
Field Align . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Low Light Sharpness . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Minimum Focus Distance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Software/Language File Upload . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Description Spectra® IV SL and Spectra IV SE are Pelco’s premier integrated dome systems. These systems feature a high resolution camera/optics package with configurable dome drive software. This manual is designed primarily to be a reference tool for the installation and operation of your system. Inside you will find information about features and commands, as well as a detailed menu tree and a quick start guide.
Installation This manual contains installation instructions for the Spectra IV dome drive only. For complete installation instructions for a Spectra IV dome system, refer to the installation manual that was shipped with the back box. SWITCH SETTINGS Before installing the dome drive, you must configure the receiver address, termination, and baud setting. The DIP switches used to configure these settings are located on the base of the dome drive. Figure 1 shows the default settings for the DIP switches.
Pelco P Protocol Control Systems To compensate for Pelco P protocol control systems from other manufacturers, set SW2-3 to the ON position. This may improve dome control with some of these control systems. SW2 SWITCHES 4 AND 5: SERIAL PORT SETTINGS RS-422 Setting (Default) SW2-4 and SW2-5 should both be set to the OFF position for RS-422 setting. For control, only two wires should be connected to the RX- and RX+ connectors on the circuit board inside the back box.
DOME DRIVE To install the dome drive: 1. Align the blue and red tabs with the blue and red arrows on the hinged door inside the back box. 2. Push the tabs in. Insert one side and then the other side. 3. Continue pushing on the ends of the tabs until both sides click into place (refer to Figure 2). Figure 2. Dome Drive Installation NOTE: When removing a dome drive that has been in use, caution should be taken to avoid direct contact with the top plate of the unit.
Operation QUICK OPERATION GUIDE Pan and Tilt Move the joystick or press the direction keys left/right and up/down. Zoom Far To zoom far: 1. Press the Zoom Tele button or turn the joystick clockwise until zoom stops at the optical zoom limit. 2. Release the button or joystick for one second. 3. To continue zooming (digitally), press the button or turn the joystick clockwise again until you have the picture you want or reach the digital zoom* limit.
PRESET 95: ACCESSING MAIN MENU You can call up the main menu on your monitor by configuring (setting or creating) preset 95 (preset 28 in AD-32 preset mode). Configuring preset 95 for Pelco’s controllers varies according to the type of controller you are using. Instructions for configuring preset 95 are given below for various Pelco controllers. CM6700/CM6800 1. Enter the number of the Spectra IV dome system and press the CAM key. 2. Enter 95 and hold the PRESET key for two seconds. 3.
ENDURA WORKSTATION 1. Right-click in the video pane of the Spectra IV dome system. 2. Click Preset and then click Select Preset. 3. Enter 95 and then click OK. VCD5000 1. Enter 95 for the preset action. The shortcuts menu appears. 2. Press the Preset button on the KBD5000. DX4100/DX4500/DX4600/DX8100 1. Click the PTZ button on the toolbar. The PTZ control appears. 2. Click the Program button on the PTZ control. The main menu appears. DIGITAL SENTRY® SYSTEM SOFTWARE 1. Click the PTZ tab. 2.
23X LowLight Day/Night Menu Tree SPECTRA IV LANGUAGE ENGLISH ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM SYSTEM INFORMATION DISPLAY SETUP SERIAL # XXXXXXXXXXXXXX DOME DRIVE MODEL XX-XXXX AVAILABLE BACK BOX MEMORY XX.X SOFTWARE VERSION BUILD XX.X FONT VERSION XXXXXXXXXX COMM 1 D ADDRESS 2 P ADDRESS OFF CM95OO MODE OFF 32 PRESETS C PROTOCOL X.
DOME SETTINGS * LINE SYNC LINE SYNC LINE SYNC PHASE PRESETS ON 0 PATTERNS PRESET NUMBER ***PRESET NOT DEFINED*** 1 PATTERN NUMBER REFERENCE INFO PATTERN USAGE REMAINING REFERENCE INFORMATION AZIMUTH ELEVATION ZOOM CUSTOM CAMERA SE
27X LowLight Day/Night Menu Tree SPECTRA IV LANGUAGE ENGLISH ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM SYSTEM INFORMATION DISPLAY SETUP SERIAL # XXXXXXXXXXXXXX DOME DRIVE MODEL XX-XXXX BACK BOX MEMORY AVAILABLE SOFTWARE VERSION XX.X BUILD FONT VERSION XX.X COMM XXXXXXXXXX D ADDRESS 1 P ADDRESS 2 CM95OO MODE OFF 32 PRESETS OFF PROTOCOL C PRESSURIZED* X.
DOME SETTINGS * POWER UP POWER UP ACTION LINE SYNC AUTO ALARMS PRESETS ON 0 OFF 5 0 EDIT THE PASSWORD OK CANCEL BACKSPACE SPACE ALARM NUMBER ALARM PRIORITY ALARM ACTION ACTIVATE AUX ALARM CONTACT MOTION DETECTION PRESET NUMBER ***PRESET NOT DEFINED***
35X LowLight Day/Night Menu Tree SPECTRA IV LANGUAGE ENGLISH ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM SYSTEM INFORMATION DISPLAY SETUP SERIAL # XXXXXXXXXXXXXX DOME DRIVE MODEL XX-XXXX AVAILABLE BACK BOX MEMORY XX.X SOFTWARE VERSION BUILD XX.X FONT VERSION XXXXXXXXXX COMM 1 D ADDRESS 2 P ADDRESS OFF CM95OO MODE OFF 32 PRESETS C PROTOCOL X.
DOME SETTINGS * POWER UP POWER UP ACTION LINE SYNC AUTO LINE SYNC LINE SYNC PHASE PRESETS ON 0 MOTION DETECTION PRESET NUMBER ***PRESET NOT DEFINED*** MOTION DETECTION ENABLED
Language SPECTRA IV LANGUAGE ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT The language for the on-screen menus is selectable. Available languages include English, Spanish, French, German, Italian, Portuguese, Russian, Polish, Turkish, and Czech. The factory default language is English. To change the display language: 1. Use the joystick to position the cursor beside LANGUAGE. 2. Press Iris Open.
System Information ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT ADDITIONAL SYSTEM INFORMATION SPECTRA IV LANGUAGE SERIAL # DOME DRIVE MODEL BACK BOX MEMORY SOFTWARE VERSION BUILD FONT VERSION FREE MEMORY LAST RESET AZIMUTH ZERO OFFSET MOTOR ACTIVE CAMERA ACTIVE VIDEO LEVEL CAMERA MODEL LANGUAGE 1 LANGUAGE 2 LANGUAGE 3 LANGUAGE 4 LANGUAGE 5 LANGUAGE 6 LANGUAGE 7 LANGUAGE 8 LANGUAGE 9 LANGUAGE 10 COMM D ADDRESS
Display Setup DISPLAY SETUP SPECTRA IV LANGUAGE ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT PRESET LABEL ZONE LABEL ZOOM AZIMUTH/ELEVATION DIRECTION ALARM MESSAGE DATE/TIME EVENT LABEL
LABEL POSITIONS DISPLAY SETUP SPECTRA IV LANGUAGE ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT PRESET LABEL ZONE LABEL ZOOM AZIMUTH/ELEVATION DIRECTION ALARM MESSAGE DATE/TIME EVENT LABEL
Dome Settings CAMERA DOME SETTINGS SPECTRA IV LANGUAGE ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT * BACK EXIT CAMERA TYPE OF LIGHTING PICTURE MODE AUTO FOCUS SURE FOCUS PT FOCUS LOCK ZOOM LIMIT ZOOM SPEED LOW LIGHT LIMIT IR CUT FILTER AUTO IR LEVEL LOW LIGHT FOCU
PT Focus Lock Pan/tilt (PT) focus lock holds the focus position of the lens during PTZ to maintain accurate focus between scenes, especially during the execution of presets and in low-light scenes. There are two settings: ON: PT focus lock is enabled. OFF (default): PT focus lock is disabled. ZOOM LIMIT (Applies to 27X and 35X models only.) Zoom limit allows the user to define a limitation on the amount of telephoto zoom. The settings vary depending on camera model.
IR CUT FILTER Spectra IV dome systems have two modes of operation: color, and black-white. You can increase sensitivity in low light conditions by switching to black-white mode (removing the IR cut filter). Color mode is preferred in normal lighting conditions. The following are the settings for the IR cut filter: OFF: Manual operation is controlled by preset 88 (filter IN) and 89 (filter OUT). AUTO (default): Automatic operation is controlled by the auto IR level setting.
ADVANCED CAMERA SETTINGS SPECTRA IV LANGUAGE ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT DOME SETTINGS * BACK EXIT ADVANCED SETTINGS CAMERA TYPE OF LIGHTING PICTURE MODE AUTO FOCUS SURE FOCUS PT FOCUS LOCK ZOOM LIMIT ZOOM SPEED LOW LIGHT LIMIT IR CUT FILTER AUTO I
Auto Iris Peak Increasing the peak value will cause the auto iris circuit to react more to highlights or “peaks” in the picture. Decreasing this value will cause it to use the average video level to adjust the iris. AUTO SHARPNESS Auto sharpness enhances picture detail by increasing the aperture gain of the camera and sharpening the edges in the picture. There are two settings: ON (default): The camera automatically maintains a normal sharpness mode.
NOTE: Wide dynamic range is disabled when electronic image stabilization is set to 5 Hz or 10 Hz. Wide Dynamic Range ON Wide Dynamic Range OFF Figure 3. Wide Dynamic Range Settings LOW LUX NOISE REDUCTION (Applies to 27X and 35X models only.) Low lux noise reduction helps to reduce video noise in low light scenes. When enabled, low lux noise reduction is directly affected by the AGC settings for the dome system.
LOW LIGHT SHARPNESS (Applies to 27X and 35X models only.) Low light sharpness allows you to control the video sharpness in low-light scenes. The available settings are 20, 10, DEFAULT, –10, and –20. Increasing the value increases sharpness in low-light scenes, but also increases video noise. Decreasing the value decreases video noise in low-light scenes, but it also decreases image sharpness.
PARK TIME This feature allows the dome to begin a specified operation (scan, preset, or pattern) after a configured period of inactivity. Park time can be configured from 1 to 720 minutes (12 hours), or set to zero, which disables this feature. The default setting is zero. Park Action This feature will define the activity when the dome parks. The following settings are available: NONE (default): No action. AUTO SCAN: Dome starts auto scan operation. FRAME SCAN: Dome starts frame scan operation.
To set manual or scan stops: 1. Use the joystick to position the cursor beside SET MANUAL STOPS or SET SCAN STOPS. 2. Press Iris Open. 3. Follow the directions displayed on the monitor. NOTE: In order for the manual or scan stops to work, the LIMIT STOPS option must be ON. To clear manual or scan stops: 1. Use the joystick to position the cursor beside CLEAR MANUAL STOPS or CLEAR SCAN STOPS. 2. Press Iris Open. 3. Follow the directions displayed on the monitor.
DISPLAY SETUP When display setup is enabled, you are notified that the camera detects motion in a scene. There are two settings: ON (default): Display setup is enabled and a transparent blue rectangle appears in the area of the scene where motion has been detected. OFF: Display setup is disabled. SENSITIVITY Sensitivity adjusts the camera’s sensitivity to motion, thereby adjusting the number of moving objects that will be tracked automatically.
POWER UP (Applies to 27X and 35X models only.
LINE SYNC DOME SETTINGS SPECTRA IV LANGUAGE ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT LINE SYNC LINE SYNC LINE SYNC PHASE * BACK EXIT BACK EXIT Line sync refers to a configurable function that allows you to synchronize all cameras within a matrix system.
The Spectra IV SL dome system, which includes 23X models, has 64 preset positions. The presets that can be configured are numbered 1 to 32 and 35 to 64. The Spectra IV SE dome system, which includes 27X and 35X models, has 256 preset positions. The presets that can be configured are numbered 1 to 32, 35 to 82, and 100 to 256. NOTE: The number of available presets may be limited by the head-ins, controllers, and DVRs that are connected to your dome system.
Use the following steps to configure a preset. 1. Select the preset number: a. Use the joystick to position the cursor beside PRESET NUMBER. Press Iris Open. The cursor moves to the right. b. Move the joystick up or down to view selections. Press Iris Open to enter selection. 2. Edit the preset label: a. Use the joystick to position the cursor beside EDIT PRESET LABEL. b. Press Iris Open.
MOTION DETECTION (Applies to 27X and 35X models only.
MOTION DETECTION AREAS Figure 4. Motion Detection Areas 2. Set the sensitivity of the motion detection area: a. Position the cursor next to SENSITIVITY for DETECTION AREA 1, 2, 3, or 4. b. Press Iris Open, the cursor moves to the right. c. Use the joystick to select one of the following sensitivity levels: HIGH: The sensitivity level is high. MEDIUM (default): Average sensitivity. LOW: The sensitivity level is low. d. Press Iris Open to make selection.
PATTERNS SPECTRA IV LANGUAGE ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT DOME SETTINGS * BACK EXIT PATTERNS PATTERN NUMBER BACK EXIT REFERENCE INFORMATION PATTERN USAGE REMAINING A pattern is a memorized, repeating
ZONES SPECTRA IV LANGUAGE ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT DOME SETTINGS ZONES ZONE NUMBER * * * ZONE NOT DEFINED * * * * BACK EXIT ZONE ENABLED ZONE BLANKING BACK EXIT A zone is a pan area, defined by a left
WINDOW BLANKING DOME SETTINGS SPECTRA IV * BACK EXIT LANGUAGE ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT WINDOW BLANKING SET WINDOWS STYLE WINDOW NUMBER BLANK ALL ABOVE BLANK ALL BELOW
• Set windows are not visible when editing a new window location. Disabled Enabled Figure 6. Window Blanking 6. The blanked area can be configured to turn on or off at a specified zoom point. To set the zoom point: a. Use the joystick to position the cursor beside EDIT WINDOW ZOOM, and then press Iris Open. b. Zoom in to the point where you want window blanking to turn on. Press Iris Open to set the zoom point.
BLANK ALL ABOVE/BLANK ALL BELOW The Blank All Above and Blank All Below options add additional flexibility to setting up privacy areas. These settings are ideal for applications where a complete pan location needs to be blanked. Table E.
ALARMS DOME SETTINGS SPECTRA IV LANGUAGE ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT * BACK EXIT ALARMS RESUME SEQUENCE (SECS) RESET DELAY (SECS) BACK EXIT ALARM SETTINGS ALARM NUMBER ALARM PRIORITY ALARM ACTION ACTIVATE AUX ALARM CONTACT
4. Set the alarm action: a. Use the joystick to position the cursor beside ALARM ACTION. b. Press Iris Open. The cursor moves to the right. c. Move the joystick up or down to view the available selections. The following are the settings for alarm action: NONE: No action when alarm is triggered. AUTO SCAN: Dome starts auto scan operation when alarm is triggered. FRAME SCAN: Dome starts frame scan operation when alarm is triggered. RANDOM SCAN: Dome starts random scan operation when alarm is triggered.
AUX SPECTRA IV LANGUAGE ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT DOME SETTINGS * BACK EXIT AUX AUX 1 MODE DWELL TIME (SECS) AUX 2 MODE DWELL TIME (SECS) TOGGLE 1 TOGGLE 1 BACK EXIT An auxiliary output is a configurable signal from the dome bac
TITLE TEXT SPECTRA IV LANGUAGE ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT TITLE TEXT DOME SETTINGS ENABLE TITLE TEXT * BACK EXIT BACK EXIT Title text is the label used to identify the camera viewed on the monitor.
ALERT SPECTRA IV LANGUAGE ACK ALERT RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT DOME SETTINGS ALERT REPEAT ACK ACTION ACTIVATE AUX RESET ALERT BACK EXIT BACK EXIT NOTE: The Alert option applies to Pressurized Spectra IV dome systems only.
ACTIVATE AUX This setting activates an auxiliary when an alert condition exists. Settings include the following options: NONE (default): Not activated. 1: An alert condition will close AUX 1. 2: An alert condition will close AUX 2. CURRENT READING The Current Reading menu displays the existing status of temperature, pressure, and dew point inside the dome system. An arrow displayed to the left of a menu item denotes that an alert condition exists.
CLEAR SPECTRA IV LANGUAGE ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT DOME SETTINGS * BACK EXIT CLEAR CLEAR ALL ZONES CLEAR ALL PRESETS CLEAR ALL PATTERNS CLEAR ALL WINDOW BLANKING CLEAR ALL EVENTS RESTORE FACTORY DEFAULTS BACK EXIT Use this setting to clear user-
CLOCK ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT CLOCK DOME SETTINGS SPECTRA IV LANGUAGE * BACK EXIT TIME BASE TIME FORMAT SET TIME DATE FORMAT SET DATE DAYLIGHT SAVINGS BACK EXIT The clock is used to set the current date and time.
7. If FIXED DATE was selected, the following information appears: CLOCK TIME BASE TIME FORMAT SET TIME INTERNAL CLOCK 12 HOUR 00:00 AM DATE FORMAT SET DATE MM/DD/YYYY 00/00/0000 DAYLIGHT SAVINGS TIME SHIFT START DATE MONTH DAY START TIME FIXED DATE 1 HOUR MARCH 1 02:00 AM END DATE MONTH DAY END TIME NOVEMBER 1 02:00 AM BACK EXIT a. Use the joystick to position the cursor beside TIME SHIFT. Press Iris Open. Scroll through the options until the desired selection appears.
EVENT (Applies to 27X and 35X models only.
EVENT LABEL Set the event label to NEW to create a new event. Use the following steps to manage an existing event. 1. Use the joystick to position the cursor beside EVENT LABEL. Press Iris Open. 2. Move the joystick up or down to scroll through the events. Press Iris Open to enter selection. As you scroll through the events, the reference information at the bottom of the screen displays the corresponding details for each event. To view a list of all events and their details, refer to List Event on page 55.
d. Follow the instructions in the previous step for the remaining days of the week. e. Use the joystick to position the cursor beside HOLIDAY. Press Iris Open. The following are the holiday settings: SKIP HOLIDAYS: The event will not occur on a day of the week for which it is set if that date is in the list of holidays. ON: The event will activate on holidays that are set in the Event menu, in addition to its normally scheduled days of the week.
4. If FIXED DATE was selected as the occurrence, the following information appears: EDIT HOLIDAY OCCURRENCE MONTH DAY FIXED DATE JANUARY 1 BACK EXIT a. Use the joystick to position the cursor beside MONTH. Press Iris Open. Scroll through the options until the desired month appears. Press Iris Open to select the month. b. Use the joystick to position the cursor beside DAY. Press Iris Open. Scroll through the options until the desired date appears. Press Iris Open to select the day. 5.
SCHEDULED EVENTS Use this page to record scheduled events. EVENT NUMBER EVENT TYPE LABEL TIME OCCURS HOLIDAY Example: 1 Preset Weekend 11:00 AM Sat–Sun Skips Holidays Description: Camera focuses on gate on weekends when the office is closed.
Reset, Cycle Power, Reboot SPECTRA IV LANGUAGE ENGLISH ACK ALERT* RESET CAMERA CYCLE CAMERA POWER REBOOT SYSTEM EXIT RESET CAMERA Use this function to reset all camera settings to factory default parameters. CYCLE CAMERA POWER If the camera is not operating or if you lose camera control, cycle camera power. Cycling camera power resets the camera but does not change any saved camera settings.
Software/Language File Upload The RJ-45 data port of the dome drive allows access for on-site setup, testing, and uploading of revised operating software and language files. A Pelco field service tool is required to perform these operations. Field service tools include Pelco’s remote monitor kit (IPS-RMK), remote data port box (IPS-RDPE-2), and remote monitor cable (IPS-CABLE).
Maintenance The Spectra IV dome systems do not require any special maintenance. Occasionally, dust may build up on the inside or the outside of the dome. If this occurs, turn power off to the unit and remove the lower dome from the back box. Remove the dust from the lower dome using compressed air from a spray can. Replace the lower dome following the installation instructions that were shipped with it. Warning: Proper eye protection should be worn when using compressed air cans.
Specifications 23X MODELS DD423 Signal Format NTSC Scanning System 2:1 Interlace Image Sensor 1/4-inch progressive scan CCD Effective Pixels 768 (H) X 494 (V) Horizontal Resolution 540 TV lines Lens f/1.6 (focal length, 3.6 ~ 82.8 mm; 23X optical zoom, 12X digital zoom) Zoom Speed (optical range) 2.9/4.2/5.8 seconds Horizontal Angle of View 54° at 3.6 mm wide zoom; 2.5° at 82.8 mm telephoto zoom Focus Automatic with manual override Maximum Sensitivity at 35 IRE 0.
27X MODELS DD427 Signal Format NTSC Scanning System 2:1 Interlace/1:1 Progressive (user-selectable) Image Sensor 1/4-inch CCD Effective Pixels 768 (H) X 494 (V) Horizontal Resolution >540 TV lines Lens f/1.4 (focal length, 3.4 ~ 119 mm; 35X optical zoom, 12X digital zoom) Zoom Speed (optical range) 3.2/4.6/6.6 seconds Horizontal Angle of View 55.8° at 3.4 mm wide zoom; 1.7° at 119 mm telephoto zoom Focus Automatic with manual override Maximum Sensitivity at 35 IRE 0.
35X MODELS DD4CBW35 Signal Format NTSC Scanning System 2:1 Interlace/1:1 Progressive (user-selectable) Image Sensor 1/4-inch CCD Effective Pixels 768 (H) X 494 (V) Horizontal Resolution >540 TV lines Lens f/1.4 (focal length, 3.4 ~ 119 mm; 35X optical zoom, 12X digital zoom) Zoom Speed (optical range) 3.2/4.6/6.6 seconds Horizontal Angle of View 55.8° at 3.4 mm wide zoom; 1.7° at 119 mm telephoto zoom Focus Automatic with manual override Maximum Sensitivity at 35 IRE 0.
Appendix Table F.
Table G.
Table G.
Table G.
Table G.
Table G.
Table G.
PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment.
www.pelco.