INSTALLATION/OPERATION ® VS5004/VS5008 Sequential Switcher C808M-G (4/05)
Contents Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Installation . . . . . . . . . . . . . . . . . . . . . . . .
Description The VS5004 and VS5008 sequential switchers are designed to switch up to four (VS5004) or eight (VS5008) cameras manually or automatically to one or two monitors with automatic response to alarm inputs. Both versions are Coaxitron® compatible and can be placed on a desktop or rack mounted.
Installation TERMINATED CAMERA INPUTS AND ONE MONITOR OUTPUT 1. Make all equipment connections. Refer to Figure 1 (VS5004) or Figure 2 (VS5008). VS5008 only: When configured for one-monitor operation, the monitor must be connected to the MON 2 output. The MON 1 output must be terminated with a 75-ohm BNC terminator. 2. Make alarm connections if required. Refer to Figure 3 (VS5004) or Figure 4 (VS5008) and do the following: VS5004 a.
NOTE: MON 1 MUST BE TERMINATED. ALARM INPUT 12 VAC CAMERAS COM 8 INPUT 1 2 3 4 5 6 7 8 7 6 5 4 MON 1 3 2 1 MON 2 MON X ALARM OUT VS5008 (REAR) Figure 2. VS5008 Terminated Camera Inputs - One Monitor 6-PIN CONNECTOR RECEPTACLE YEL REAR VIEW CAMERAS ALARM MON 1 4 3 2 1 MON 2 4 3 2 1 BRN GRN 4 1 RD BLK 5 2 OR 6 3 12VAC INPUT IN 1 2 3 4 OUT 6 -- TO VCR COMMON 5 TO EXTERNAL ALARM CIRCUITRY Figure 3.
UP TO EIGHT ALARM INPUTS (ALARM INPUT FROM MOTION DETECTOR, DOOR CONTACT, ETC., THROUGH NORMALLY OPEN SWITCH). EACH ALARM DEVICE MUST BE CONNECTED TO THE "COM" TERMINAL. UP TO EIGHT VIDEO INPUTS ALARM INPUT 12 VAC CAMERAS COM 8 INPUT 1 2 3 4 5 6 7 8 7 6 5 4 MON 1 3 2 1 MON 2 MON X ALARM OUT VS5008 (REAR) VCR OPEN COLLECTOR OUTPUT FOR VCR ACTIVATION IN ALARM CONDITION. ONLY ONE VCR CAN BE USED IN THIS CONFIGURATION. Figure 4.
LOOPING CAMERA INPUTS AND ONE MONITOR OUTPUT 1. Convert the switcher to looping operation. Refer to Figure 5 and do the following: NOTE: Looping and terminated inputs may be mixed. a. Remove the cover. b. Remove the rear panel of the chassis. c. Locate the 75-ohm resistors located on the inside of the rear panel BNC jacks. d. For each input to be looped, use wire cutters to clip one of the attached resistor leads. e. Replace the cover. 2. Make all equipment connections.
75-OHM RESISTOR CLIP HERE FOR EACH CHANNEL REAR PANEL (SWITCHER) BNC CONNECTOR Figure 5. Looping Conversion Modification MON 1 BRIGHT CONTRAST ALARM MON 1 4 3 2 12 VAC INPUT 1 IN 1 2 3 4 OUT 6 COMMON 5 MON 2 VIDEO INPUTS ADDITIONAL EQUIPMENT TERMINATED Figure 6.
NOTE: IN THIS CONFIGURATION, MON 1 MUST BE TERMINATED AND THE UNIT MUST BE MODIFIED TO BE LOOPING (REFER TO FIGURE 5). ALARM INPUT 12 VAC CAMERAS COM 8 INPUT 1 2 3 4 5 6 7 8 7 6 5 4 MON 1 3 2 1 MON 2 MON X ALARM OUT VS5008 (REAR) VIDEO INPUTS ADDITIONAL EQUIPMENT TERMINATED Figure 7. VS5008 Looping Camera Inputs - One Monitor TERMINATED CAMERA INPUTS AND TWO MONITOR OUTPUTS 1. Convert the VS5004 to dual-monitor operation. Refer to Figure 8 and do the following: a.
4. Set the ALARM switch to the ON position. NOTES: • With all channel switches set to the AUTO position, both monitors immediately switch to the alarmed channel and the associated LED blinks. Multiple alarmed channels sequence every five seconds (VS5004) or three seconds (VS5008). The alarm has priority over the MONITOR/AUTO/BYPASS switch settings. • If a channel switch is set to the MONITOR position, Monitor 1 switches to the alarmed channel while Monitor 2 displays the selected (MONITOR) channel.
MON 2 BRIGHT MON 1 CONTRAST BRIGHT CONTRAST ALARM MON 1 4 3 2 12 VAC INPUT 1 IN 1 2 3 4 OUT 6 COMMON 5 MON 2 NOTE: IN THIS CONFIGURATION, MON 1 MUST BE TERMINATED WITH A 75-OHM TERMINATOR AND MON 2 MUST BE IN THE “HI Z” POSITION. Figure 9. VS5004 Terminated Camera Inputs - Two Monitors ALARM INPUT 12 VAC CAMERAS COM 8 INPUT 1 2 3 4 5 6 7 8 7 6 5 4 MON 1 3 2 1 MON 2 MON X ALARM OUT VS5008 (REAR) Figure 10.
LOOPING CAMERA INPUTS AND TWO MONITOR OUTPUTS 1. Convert the VS5004 to dual-monitor operation. Refer to Figure 8 and do the following: a. Remove the cover. b. Remove the rear panel of the chassis. c. Remove the four screws attaching the PC board to the chassis. d. Pull the PC board and rear panel assembly out of the chassis. e. Turn the PC board over and rewire. 2. Convert to looping operation. Refer to Figure 5 and do the following: NOTE: Looping and terminated inputs may be mixed. a.
7. Connect the AC adapter to the 12 VAC input plug on the rear of the VS5004 or VS5008. Connect the transformer to a 120 VAC (VS5004 or VS5008) or 230 VAC (VS5004/220 or VS5008/220) power source. After power up, the switcher will begin sequencing. 8. Using a screwdriver, adjust the DWELL interval control to the desired setting. This control adjusts the interval time from a minimum of 1 second to a maximum of 70 seconds nominal. To increase the interval, turn the control clockwise.
COAXITRON CONTROL To convert for use with a Coaxitron transmitter, do the following: 1. Convert the VS5004 to dual-monitor operation. Refer to Figure 8 and do the following: a. Remove the cover. b. Remove the rear panel of the chassis. c. Remove the four screws attaching the PC board to the chassis. d. Pull the PC board and rear panel assembly out of the chassis. e. Turn the PC board over and rewire. 2. Convert to looping operation.
6. For channels with cameras connected to the video inputs, set the front panel switches to the AUTO position. All unconnected video inputs should have their channel switch set to the BYPASS position. NOTES: • VS5004 and VS5008 with one-monitor configuration: All channels with a switch set in the AUTO position will automatically sequence through the monitor. To view one specific channel continuously, set the corresponding switch to the MONITOR position.
MON 1 COAXITRON® RECEIVER TO FIXED CAMERAS OR ADDITIONAL RECEIVERS BRIGHT CONTRAST 12 VAC INPUT ALARM 4 MON 1 3 2 1 IN 1 2 3 4 OUT 6 COMMON 5 MON 2 VS5004 (REAR) LOOPING OUTPUT INPUT FROM OUTPUT FROM RECEIVER MONITOR J8 J7 J6 COAXITRON® TRANSMITTER (REAR) Figure 13.
Specifications VIDEO Inputs Terminating (75 ohms) or looping Outputs Monitor 1 Monitor 2 VS5004 VS5008 Hi Z 75 ohms Monitor X VS5008 Coaxitron transmitter (nonamplified) output Gain Unity Dwell Adjustable from 1-70 seconds nominal 75 ohms Frequency Response Flat within +/-1 dB to 10 MHz Maximum Signal Level 2 Vp-p Tilt Less than 2% Crosstalk Better than -40 dB at 5.5 MHz ELECTRICAL Power Requirements for Transformer 1.5 VA (0.
C808M-G (4/05)
PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Exceptions to this warranty are as noted below: • Five years on FT/FR8000 Series fiber optic products. • Three years on Genex® Series products (multiplexers, server, and keyboard).
Worldwide Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada Tel: 800/289-9100 Fax: 800/289-9150 International Tel: 1-559/292-1981 Fax: 1-559/348-1120 www.pelco.