- 4.2.1.1 Cable wires between camera and DC/PoE power supply should be 20-22AWG.
- 4.2.1.2 Both the camera ant the end-equipment connected to it should be permanently connected to protective earth, using screw and washers. Wires should be made of cupper. Minimal grounding cable is 14AWG.
- 4.2.1.3 In case of using DC power supply:
- 4.2.1.4 Power supply (either POE injector or DC power supply) should be safety approved for local regulations.
- 4.2.1.5 Install the Ferrite on the operational cable as close as possible , max 5cm, from the system.
- 4.2.2 Mechanical Interface Preparation
- 4.2.3 Wall Mount Configuration
- 4.2.4 Pole Mount Configuration
- 4.2.5 Electrical ICD IP PoE Cable
- 4.2.1 Installation Guidelines and Preparation
- 5. Operation
- 5.1 First Time Credentials Setup
- 5.2 Logging Into Sarix TI Camera Web GUI
- 5.3 Changing Your Password
- 5.4 Main Window Overview
- 5.5 Live View Window
- 5.6 Status Window
- 5.7 Network Window
- 5.8 Streaming Window
- 5.9 Image Processing Window
- 5.10 Analytics Window
- 5.11 System Window
- 5.12 Logging Out from the Web GUI
- 6. Maintenance
- 7. Ordering Information
- 8. Index
Sarix TI Series Camera User Manual Chapter 4: Installation
4-2
4.2 Camera Installation
NOTE
Opening the Sarix TI Camera enclosure will void the product
warranty.
CAUTION
Avoid pointing the Sarix TI Camera at the sun.
4.2.1 Installation Guidelines and Preparation
Prepare your self-made IP PoE cable (cables are available for purchase, see
Table 7-3 for information).
4.2.1.1 Cable wires between camera and DC/PoE power supply should be 20-22AWG.
4.2.1.2 Both the camera ant the end-equipment connected to it should be permanently
connected to protective earth, using screw and washers. Wires should be made
of cupper. Minimal grounding cable is 14AWG.
4.2.1.3 In case of using DC power supply:
(1) The cables should be protected by fuse with maximal current of 3A
(2) The output current shall not exceed 3A after 60s
(3) The maximal output current of the power supply shall not exceed 7.5A
4.2.1.4 Power supply (either POE injector or DC power supply) should be safety
approved for local regulations.
4.2.1.5 Install the Ferrite on the operational cable as close as possible , max 5cm, from
the system.