- 4.2.1.1 Cable wires between camera and DC/PoE power supply should be 20-22AWG.
- 4.2.1.2 Both the camera ant the end-equipment connected to it should be permanently connected to protective earth, using screw and washers. Wires should be made of cupper. Minimal grounding cable is 14AWG.
- 4.2.1.3 In case of using DC power supply:
- 4.2.1.4 Power supply (either POE injector or DC power supply) should be safety approved for local regulations.
- 4.2.1.5 Install the Ferrite on the operational cable as close as possible , max 5cm, from the system.
- 4.2.2 Mechanical Interface Preparation
- 4.2.3 Wall Mount Configuration
- 4.2.4 Pole Mount Configuration
- 4.2.5 Electrical ICD IP PoE Cable
- 4.2.1 Installation Guidelines and Preparation
- 5. Operation
- 5.1 First Time Credentials Setup
- 5.2 Logging Into Sarix TI Camera Web GUI
- 5.3 Changing Your Password
- 5.4 Main Window Overview
- 5.5 Live View Window
- 5.6 Status Window
- 5.7 Network Window
- 5.8 Streaming Window
- 5.9 Image Processing Window
- 5.10 Analytics Window
- 5.11 System Window
- 5.12 Logging Out from the Web GUI
- 6. Maintenance
- 7. Ordering Information
- 8. Index
Sarix TI Series Camera User Manual Chapter 5: Operation
5-36
7. If more than one SubRegion is defined: select SubRegion-2 and mark an
ROI on the image using the mouse (example):
Figure 5-38: Image Processing Window - Histogram Calculation ROI (3 of 3)
8. Click to define the selected area as the reference for the
calculation.
9. Click . The Sub Region area is highlighted on the image and the
histogram is automatically calculated and saved.
10. To delete a Sub Region definitions: select the Sub Region (SubRegion-1 or
SubRegion-2 in the example) and click the - sign.
11. Clear the Allow Region Editing checkbox. The image is cleared from the
ROI markings and the buttons are disabled.