- 4.1 Unpacking
- 4.2 Camera Installation
- 4.2.1 Installation Guidelines and Preparation
- 4.2.1.1 Cable wires between camera and DC/PoE power supply should be 20-22AWG.
- 4.2.1.2 Both the camera ant the end-equipment connected to it should be permanently connected to protective earth, using screw and washers. Wires should be made of cupper. Minimal grounding cable is 14AWG.
- 4.2.1.3 In case of using DC power supply:
- 4.2.1.4 Power supply (either POE injector or DC power supply) should be safety approved for local regulations.
- 4.2.1.5 Install the Ferrite on the operational cable as close as possible , max 5cm, from the system.
- 4.2.2 Mechanical Interface Preparation
- 4.2.3 Wall Mount Configuration
- 4.2.4 Pole Mount Configuration
- 4.2.5 Electrical ICD IP PoE Cable
- 4.2.1 Installation Guidelines and Preparation
- 5. Operation
- 5.1 First Time Credentials Setup
- 5.2 Logging Into Sarix TI Camera Web GUI
- 5.3 Changing Your Password
- 5.4 Main Window Overview
- 5.5 Live View Window
- 5.6 Status Window
- 5.7 Network Window
- 5.8 Streaming Window
- 5.9 Image Processing Window
- 5.10 Analytics Window
- 5.11 System Window
- 5.12 Logging Out from the Web GUI
- 6. Maintenance
- 7. Ordering Information
- 8. Index
Chapter 5: Operation Sarix TI Series Camera User Manual
5-41
5.10 Analytics Window
The Analytics Window enables detecting and tracking movement within predefined ROIs, as
well as for teaching the system where movement typically occurs.
1. Click Analytics. The Analytics window opens (all collapsed):
Figure 5-42: Analytics Window (all collapsed)
The Analytics window is comprised of three tabs:
Regions Tab: enables marking of regios to detect movement (see Section 5.10.1).
Ignore Regions Tab: enables marking of regions in which movement is ignored (see Section
5.10.2).
Learning Tab: enables the system to learn the viewed scene and where movement typically
occurs (see Section 5.10.3).
NOTE
When entering the Analytics window, either of the following
messages is displayed on the lower-left corner of the screen,
depending on whether VMD is active or disabled. Click OK to close
these messages.