User Manual
Table Of Contents
- 1. Important Notices
- 2. Overview
- 3. Safety
- 4. Installation
- 4.1 Unpacking
- 4.2 Camera Installation
- 4.2.1 Installation Guidelines and Preparation
- 4.2.1.1 Cable wires between camera and DC/PoE power supply should be 20-22AWG.
- 4.2.1.2 Both the camera ant the end-equipment connected to it should be permanently connected to protective earth, using screw and washers. Wires should be made of cupper. Minimal grounding cable is 14AWG.
- 4.2.1.3 In case of using DC power supply:
- 4.2.1.4 Power supply (either POE injector or DC power supply) should be safety approved for local regulations.
- 4.2.1.5 Install the Ferrite on the operational cable as close as possible , max 5cm, from the system.
- 4.2.2 Mechanical Interface Preparation
- 4.2.3 Wall Mount Configuration
- 4.2.4 Pole Mount Configuration
- 4.2.5 Electrical ICD IP PoE Cable
- 4.2.1 Installation Guidelines and Preparation
- 5. Operation
- 5.1 First Time Credentials Setup
- 5.2 Logging Into Sarix TI Camera Web GUI
- 5.3 Changing Your Password
- 5.4 Main Window Overview
- 5.5 Live View Window
- 5.6 Status Window
- 5.7 Network Window
- 5.8 Streaming Window
- 5.9 Image Processing Window
- 5.10 Analytics Window
- 5.11 System Window
- 5.12 Logging Out from the Web GUI
- 6. Maintenance
- 7. Ordering Information
- 8. Index
Sarix TI Series Camera User Manual Chapter 5: Operation
5-50
The Analytics Settings window consists of the following parameters:
ActiveBlockPercent: Percentage of the block area that should be active in order to detect
movement (default: 70%)
BlockSize: minimum block size (default: 8)
Draw Region: enabling drawing of region
Draw Target Box: enabling frame overlay around the moving target
Draw Target Trail: enabling trail showing the path the moving target has taken. The
maximum trail length is determined by “MaxTargetTrailLength”
Initial Noise Level: higher level reduces the effect of noise in a scene, but also reduces
detection sensitivity (default: 6)
LearningTime: length of time, in seconds, the learning session will run (default: 30 seconds)
MaxTargetTrailLength: trail length, in FPS (default: 120 FPS). Will not display if “Draw
Target Trail” is not enabled
Scene History: minimum number of frames that are used for movement detection (default:
2)
TTL: length of time, in seconds, a target will continue to be considered a target after it
hasn’t been seen (default: 2 seconds)
Track All Frame: enabling tracking of target in entire image frame, not just in the ROI the
object was detected in
Warning Time: elapsed time, in seconds, until the system defines the identified object as a
target (default: 0.4 seconds)
NOTE
To close the Analytics Settings screen, click in the upper-right
corner of the screen. Any changes that were made are retained.