Sarix TI Series Camera User Manual C6622M September 2019
Pelco Troubleshooting Contact Information If the instructions provided fail to solve your problem, contact Pelco Product Support at 1-800-289-9100 (USA and Canada) or +1-559-292-1981 (international) for assistance. Be sure to have the serial number available when calling. Do not try to repair the unit yourself. Leave maintenance and repairs to qualified technical personnel only.
Chapter 1: Important Notices Sarix TI Series Camera User Manual List of Revisions No. 1.
Chapter 1: Important Notices Sarix TI Series Camera User Manual Table of Contents 1. Important Notices ............................................................................................................................. 1-8 1.1 1.6 1.7 1.8 Regulatory Notices [FCC Class A] ..................................................................................................... 1-8 1.1.1 Radio and Television Interference ..............................................................................
Chapter 1: Important Notices Sarix TI Series Camera User Manual 5.2 5.3 5.4 5.5 5.6 Logging Into Sarix TI Camera Web GUI ........................................................................................... 5-3 Changing Your Password ................................................................................................................... 5-5 Main Window Overview ....................................................................................................................
Chapter 1: Important Notices Sarix TI Series Camera User Manual 7.1 7.2 Ordering Information ........................................................................................................................ 7-64 Ordering Accessories ........................................................................................................................ 7-64 8. Index ....................................................................................................................................
Chapter 1: Important Notices List of Figures Figure 2-1: Figure 2-2: Figure 2-3: Figure 2-4: Figure 4-1: Figure 4-2: Figure 4-3: Figure 4-4: Figure 4-5: Figure 5-1: Figure 5-2: Figure 5-3: Figure 5-4: Figure 5-5: Figure 5-6: Figure 5-7: Figure 5-8: Figure 5-9: Figure 5-10: Figure 5-11: Figure 5-12: Figure 5-13: Figure 5-14: Figure 5-15: Figure 5-16: Figure 5-17: Figure 5-18: Figure 5-19: Figure 5-20: Figure 5-21: Figure 5-22: Figure 5-23: Figure 5-24: Figure 5-25: Figure 5-26: Figure 5-27: Figure 5-28: Fig
Chapter 1: Important Notices Figure 5-33: Figure 5-34: Figure 5-35: Figure 5-36: Figure 5-37: Figure 5-38: Figure 5-39: Figure 5-40: Figure 5-41: Figure 5-42: Figure 5-43: Figure 5-44: Figure 5-45: Figure 5-46: Figure 5-47: Figure 5-48: Figure 5-49: Figure 5-50: Figure 5-51: Figure 5-52: Figure 5-53: Figure 5-54: Figure 5-55: Figure 5-56: Figure 5-57: Figure 5-58: Figure 5-59: Figure 5-60: Figure 5-61: Figure 5-62: Figure 5-63: Figure 5-64: Figure 5-65: Figure 5-66: Figure 5-67: Figure 5-68: Figure 5-69: Fi
Chapter 1: Important Notices List of Tables Table 2-1: Table 2-2: Table 2-3: Table 2-4: Table 4-1: Table 7-1: Table 7-2: Table 7-3: 1-7 Sarix TI Series Camera User Manual Technical Data and Specifications - System Specifications............................................... 2-18 Technical Data and Specifications - Configurations .......................................................... 2-19 Technical Data and Specifications - Thermal Camera .......................................................
Chapter 1: Important Notices 1. Important Notices 1.1 Regulatory Notices [FCC Class A] Sarix TI Series Camera User Manual This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 1.1.
Chapter 1: Important Notices Sarix TI Series Camera User Manual AGREEMENT AND RESULT IN THE IMMEDIATE TERMINATION OF YOUR LICENSE RIGHTS THEREUNDER. 1.3 Video Quality Caution 1.3.1 Frame Rate Notice Regarding User Selected Options Pelco systems are capable of providing high quality video for both live viewing and playback. However, the systems can be used in lower quality modes, which can degrade picture quality, to allow for a slower rate of data transfer and to reduce the amount of video data stored.
Chapter 1: Important Notices Sarix TI Series Camera User Manual NOTE A CCC approved power cord must be used to power the equipment when used in China 1.5.1 2.4 GHZ Radio Device 1.6 ESD Warning WARNING: This product is sensitive to Electrostatic Discharge (ESD). To avoid ESD damage to this product, use ESD safe practices during installation. Before touching, adjusting or handling this product, correctly attach an ESD wrist strap to your wrist and appropriately discharge your body and tools.
Chapter 1: Important Notices Sarix TI Series Camera User Manual List of Acronyms and Abbreviations AWG: American Wire Gauge NUC: Non-Uniformity Correction CBR: Constant Bit Rate NV: Night Vision Histogram: Accurate representation of the distribution of numerical data.
Chapter 1: Important Notices Sarix TI Series Camera User Manual Scope of This Manual This manual provides the necessary information for introducing, installing, operating and maintaining the Sarix TI Series Camera. The manual in intended for use by technicians and operators and consists of the following chapters: Chapter 2: Overview: Introduces the Sarix TI Series Camera and its web GUI features.
Chapter 2: Overview 2. Sarix TI Series Camera User Manual Overview This chapter introduces the Sarix TI Series Camera and its web GUI features. The chapter consists of the following sections: Section 2.1: Overview Section 2.2: Features Section 2.3: Physical Description of the Camera Section 2.5: Sarix TI Web GUI Section 2.
Chapter 2: Overview 2.1 Sarix TI Series Camera User Manual Overview Sarix TI Camera is a state of the art observation system, boasting an incredibly easy installation with thermal and visual capabilities. The Sarix TI line of cameras is a broad portfolio of high performance outdoor rated cameras for 24/7 perimeter surveillance, observation, and monitoring of critical infrastructure and sensitive sites.
Chapter 2: Overview 2.3 Sarix TI Series Camera User Manual Physical Description of the Camera The Sarix TI Camera outer components include (see Figure 2-2): 1. Infrared (IR) Camera Lens 2. Main Connector (Power and Ethernet) 3. Camera-to-Pole Mount Adapter fastening screws (x4) 4. Tripod mount fastening screw 5. Complementary Metal-Oxide Semiconductor (CMOS) Camera Lens (module depended).
Chapter 2: Overview 2.
Chapter 2: Overview 2.5 Sarix TI Series Camera User Manual Sarix TI Web GUI The operation of the Sarix TI Camera is performed via Web Graphical User Interface (GUI). With the GUI you can: Setup the camera operation. Optimize the camera video. Communicate with Video Management Systems (VMS).
Chapter 2: Overview Sarix TI Series Camera User Manual 2.6 Technical Data and Specifications 2.6.1 System Specifications Applicable to models :Sarix TI 14.2mm, 35mm, and 50mm. Table 2-1: Thermal Camera: Day Camera: Video: Power Requirements: Environmental: Mechanical Parameters: System Integration: Technical Data and Specifications - System Specifications Imager Type: Uncooled ASi Microbolometer Spectral Band: 7.
Chapter 2: Overview Network: Certifications: Sarix TI Series Camera User Manual Default IP: 192.168.0.20 RTSP Port: 8554 Protocols: IPv4, HTTP, HTTPS, SSL/TLS, RTSP, DHCP EN 55032:12; EN 55024:2010+A1:2015; EN 50130-4:11+A1:14; EN 61000-3-2:14; EN 61000-3-3:13; EN 60950-1:06+A11:09+A1:10+A12:11+A2:13 UL 60950-1 2nd edition; CAN/CSA-C22.2 No. 60950-1:07+Amend 1:2011 IEC 60950-1:05+A1:09+A2:13; IEC 60950-22:16 - CE - FCC - IP66 - UL and cUL 2.6.
Chapter 2: Overview 2.6.3 Sarix TI Series Camera User Manual Thermal Camera Table 2-3: Technical Data and Specifications - Thermal Camera Configuration TI2X14 Thermal Type Uncooled Thermal Core 17µ 640 x 480 (VGA) or 17µ 384 x 288 (QVGA+) Lens Type Athermalized, Fixed Focus Focal Length 14.2mm 35mm 50mm Lens F # f/1.2 f/1.2 f/1.2 Horizontal FOV - VGA 42.1° 17.6° 12.4° Horizontal FOV - QVGA+ 25.7° 10.6° 7.5° Video Type H.
Chapter 3: Safety 3. Sarix TI Series Camera User Manual Safety This chapter provides safety instructions that technicians should be aware of during the installation, operation and maintenance of the Sarix TI Series Camera. The chapter consists of the following sections: Section 3.1: Safety Conventions Section 3.2: Safety During Installation Section 3.3: Safety During Maintenance 3.1 Safety Conventions In this manual, safety information is presented as warnings, cautions, and notes.
Chapter 3: Safety 3.2 Sarix TI Series Camera User Manual Safety During Installation To avoid injuries, follow standard safety regulations if mounting the Sarix TI Camera on an elevated location. 3.3 Safety During Maintenance Warranty void if opening the Sarix TI camera. Do not touch the Sarix TI Camera optics with bare hands. Do not use any chemicals for cleaning the Sarix TI Camera. Use only wipes approved for optical equipment.
Chapter 4: Installation 4. Sarix TI Series Camera User Manual Installation This chapter provides instructions for installing the Sarix TI Series Camera. The chapter consists of the following sections: Section 4.1: Unpacking Section 4.2: Camera Installation 4.
Chapter 4: Installation 4.2 Sarix TI Series Camera User Manual Camera Installation NOTE Opening the Sarix TI Camera enclosure will void the product warranty. CAUTION Avoid pointing the Sarix TI Camera at the sun. 4.2.1 Installation Guidelines and Preparation Prepare your self-made IP PoE cable (cables are available for purchase, see Table 7-3 for information). 4.2.1.1 Cable wires between camera and DC/PoE power supply should be 20-22AWG. 4.2.1.
Chapter 4: Installation 4.2.2 Sarix TI Series Camera User Manual Mechanical Interface Preparation NOTE It is recommended to check the functioning of the Sarix TI Camera prior to the actual installation. Figure 4-2 depicts the camera dimensions and mechanical interfaces.
Chapter 4: Installation 4.2.3 Wall Mount Configuration An arm for wall-mount is available for purchase (see Table 7-3 for information).
Chapter 4: Installation 4.2.4 Pole Mount Configuration An adapter for pole-mount is available for purchase (see Table 7-3 for information).
Chapter 4: Installation 4.2.5 Sarix TI Series Camera User Manual Electrical ICD IP PoE Cable The cable is available for purchase (see Table 7-3 for information). Cable Pinout (see Figure 4-5): Table 4-1: Electrical ICD IP PoE Cable - Pinout Connector Pin # Connector Pin # Signal Name P1 P2 (RJ45) Ethernet\POE 2 1 ETH RX+ 6 2 ETH RX11 3 ETH TX+ 15 6 ETH TX12 5,4 POE + 14 7,8 POE 8 P.S (-) 12-32vDC RTN DC Power Input 9 P.
Chapter 5: Operation 5. Sarix TI Series Camera User Manual Operation This chapter provides operating instructions for the Sarix TI Series Camera web GUI. The chapter consists of the following sections: Section 5.1: First Time Credentials Setup Section 5.2: Logging Into Sarix TI Camera Web GUI Section 5.3: Changing Your Password Section 5.4: Main Window Overview Section 5.5: Live View Window Section 5.6: Status Window Section 5.7: Network Window Section 5.8: Streaming Window Section 5.
Chapter 5: Operation 5.1 Sarix TI Series Camera User Manual First Time Credentials Setup 1. Open your web browser. 2. Type the Sarix TI Camera default IP address (192.168.0.20) in the address bar and click Enter. The First Time Setup window opens (example): Figure 5-1: Sarix TI Web GUI – First Time Setup NOTE The First Time Setup window appears the first time a user accesses the camera’s IP address. 3. Define the administrator username in the Admin Login section. 4.
Chapter 5: Operation 5.2 Sarix TI Series Camera User Manual Logging Into Sarix TI Camera Web GUI 1. Open your web browser. 2. Type the Sarix TI Camera default IP address (192.168.0.20) in the address bar and click Enter. The Status window opens (example): Figure 5-2: Sarix TI Web GUI - Status Window (before Login) 3. You may now view some default settings of your Sarix TI Camera by expanding the System, Thermal or Day tabs. 4. Click .
Chapter 5: Operation Sarix TI Series Camera User Manual 5. Enter your Username and Password: Figure 5-4: Login Window – Entering Username and Password 6. Click . The following message is displayed on the lower-left corner of the screen for three seconds, stating that you have successfully logged in. In addition, the Status window opens: Figure 5-5: Sarix TI Web GUI - Status Window (after Login) You can now use the Sarix TI Web GUI.
Chapter 5: Operation 5.3 Sarix TI Series Camera User Manual Changing Your Password 1. From the upper-right drop-down menu select Change Password: Figure 5-6: Changing Your Password - Drop Down Menu The following opens: Figure 5-7: Sarix TI Web GUI - Changing Your Password 2. Enter your Current Password. 3. Enter the New Password and re-enter in the New Password (Confirm) field. 4. Click (see Figure 5-3). . The system automatically logs out and the Login window reopen 5.
Chapter 5: Operation 5.4 Sarix TI Series Camera User Manual Main Window Overview The main areas in every window consist of the following: Figure 5-8: Main Window Overview - Main Areas Legend: 1. Menu: maneuvering between the GUI main features/tabs. 2. The name of the currently opened feature/tab. 3. Available only after logging in; a drop-down menu, enables to change your password or log out from the program. 4. The area where you can view and/or set the feature parameters.
Chapter 5: Operation 5.5 Sarix TI Series Camera User Manual Live View Window The Live View window allows viewing the Sarix TI Camera live video. 1. Click Live View. The Live View window opens, containing a live video display of both thermal and visual cameras (example): Figure 5-9: Live View Window (example) 2. To freeze the live-view video click 3. To view the video in full screen click . Click to resume the live-view video. . Click the keyboard Esc key to resume. 4.
Chapter 5: Operation 5.6 Sarix TI Series Camera User Manual Status Window The Status window allows viewing some of the Sarix TI Camera parameters and settings. 1. Click Status. The Status window opens (all collapsed): Figure 5-10: Status Window (all collapsed) The Status window is comprised of three tabs: System Tab: allows viewing general parameters related to the camera settings and its software/firmware (see Section 5.6.1).
Chapter 5: Operation 5.6.1 Sarix TI Series Camera User Manual System Tab The System tab allows viewing general parameters related to the camera settings and its software/firmware. Expand the System tab. The following opens: Figure 5-11: Status Window - System Tab The System tab consists of the following parameters: System temperature: the "System On Chip" temperature. System up time: the operating time since the last camera startup. System load: a coded indication on how the system is busy.
Chapter 5: Operation 5.6.2 Sarix TI Series Camera User Manual Thermal Tab The Thermal tab allows viewing parameters related to the thermal camera settings and its software/firmware. Expand the Thermal tab.
Chapter 5: Operation Sarix TI Series Camera User Manual The Thermal tab consists of the following parameters: Pipeline ID: the current name of the pipeline (data processing elements, connected in series, where the output of one element is the input of the next one). Pipeline Running: is the pipeline running? Pending Updates: does the pipeline requires initialization? Actual FPS: the current frame-rate where the pipeline is running. DFPA: indication from the thermal camera.
Chapter 5: Operation 5.6.3 Sarix TI Series Camera User Manual Day Tab The Day tab allows viewing parameters related to the thermal camera settings and its software/firmware. Expand the Day tab. The following opens: Figure 5-13: Status Window - Day Tab The Day tab consists of the following parameters: Pipeline ID: the current name of the pipeline.
Chapter 5: Operation 5.6.4 Sarix TI Series Camera User Manual Disabling / Enabling a Camera This option allows to disable the thermal camera and/or the CMOS camera and re-enable them. 5.6.4.1 Disabling the Camera 1. Expand the Thermal / Day tab and click . The following opens: 2. Click OK to approve.
Chapter 5: Operation Sarix TI Series Camera User Manual On completion, the following opens stating that the corresponding camera is disabled: Figure 5-15: Disabling / Enabling a Camera - System Reboot Approval The camera view does not appear anymore on the Live View window. 5.6.4.2 Enabling the Camera 1. Expand the Thermal / Day tab and click . The following opens: 2. Click OK to approve. The system re-boots (see Figure 5-14).
Chapter 5: Operation 5.7 Sarix TI Series Camera User Manual Network Window The Network window allows configuring the HOST-to-Camera Ethernet communication method. 1. Click Network.
Chapter 5: Operation 5.7.1 Sarix TI Series Camera User Manual Setting of IP Address To change the IP address, Subnet mask or Gateway values: 1. Click on the corresponding address and change the value either using the the IP address using the keyboard. An example is shown in Figure 5-17: button or type Figure 5-17: Network Window - Changing an Address 2. Click changes). 5.7.
Chapter 5: Operation 5.7.3 Sarix TI Series Camera User Manual Setting a Manual DNS Server Address This option is applicable when you wish to synchronize the time and date with a DNS server (see Section 5.11.3.2). To manually select a DNS server address: 1. Enable the DNS area by selecting the Obtain IP address automatically checkbox. The Obtain DNS servers automatically checkbox is automatically selected. 2. Clear the Obtain DNS servers automatically checkbox. 3. Click . An empty DNS line is added. 4.
Chapter 5: Operation 5.7.6 Sarix TI Series Camera User Manual Resetting Network Settings To revert network settings back to factory defaults: 1. Click . The following opens: Figure 5-19: Network Window - Resetting IP Address Approval 2. Click OK to revert network settings back to factory defaults. 5.7.7 Restarting ONVIF Service To restart the system and reload ONVIF service: Click .
Chapter 5: Operation 5.7.8 Sarix TI Series Camera User Manual Certificates 5.7.8.1 Creating a Certificate Request This option allows retrieval of a Secure Sockets Layer (SSL) certificate. 1. Select the Certificates tab. The following opens: Figure 5-21: Certificates - Creating a Certificate Request 2. Enter/select the following details: • • • • • • Common Name (compulsory; an IP address or system Host name). State or Province Country (select from the drop-down list) City Organization Department 3.
Chapter 5: Operation Sarix TI Series Camera User Manual 2. Enter/select the following details: • • • • • • • Common Name (compulsory; an IP address or system Host name). State or Province Country (select from the drop-down list) City Organization Department Validity (in days) 3. Click 5.7.8.3 . Your self-signed certificate is submitted for approvals. Uploading a Certificate This option allows loading an existing certificate, originated by another source. 1. Select the Upload Certificate option.
Chapter 5: Operation 5.8 Sarix TI Series Camera User Manual Streaming Window The Streaming window allows configuring the video flow-rate and the video encoding method. 5.8.1 Thermal Tab 1. Click Streaming. The Streaming - Thermal Tab opens: Figure 5-24: Streaming Window - Thermal Tab 2. Under each option in the Thermal Tab you can: 5-21 • Click to restart the video streaming. • Click to stop the video streaming. • Click to re-start the video streaming.
Chapter 5: Operation 5.8.1.1 Sarix TI Series Camera User Manual Main Stream Expand the Main Stream option. The following opens (click effect; click to revert your changes): for the changes to take Figure 5-25: Streaming Window - Thermal Tab - Main Stream The main stream option consists of the following parameters: Misc Properties parameters: • CBR: the video flow-rate (Kb/Sec). • IntraQp: an auto calculation of the I-level quality-level (default: -1).
Chapter 5: Operation 5-23 Sarix TI Series Camera User Manual • Unit Type: selection of the installed camera/lens type and the installation method. • Video Encoding: selection of the video coding (mjpeg requires a system restart). • Image Size/Rate: selection of the video that will be taken from the camera.
Chapter 5: Operation 5.8.1.2 Sarix TI Series Camera User Manual Secondary Stream Expand the Secondary Stream option. The following opens (click take effect; click to revert your changes): for the changes to Figure 5-26: Streaming Window - Thermal Tab - Secondary Stream The secondary stream option consists of the following parameters: VBR quality factor: 1 is the lowest level. GOP I-frame spacing: Group Of Pictures; how many frames will include an Intra-Frame.
Chapter 5: Operation 5.8.2 Sarix TI Series Camera User Manual Day Tab Under each option in the Day Tab you can: • Click to restart the video streaming. • Click to stop the video streaming. • Click to re-start the video streaming. 5.8.2.1 Main Stream Expand the Main Stream option.
Chapter 5: Operation 5-26 Sarix TI Series Camera User Manual • Unit Type: selection of the installed camera/lens type and the installation method. • Video Scale: the video resolution; "NO CHANGE": 1280 x 720 (HD). • Video Encoding: selection of the video coding (mjpeg requires a system restart). • Image Size/Rate: selection of the video that will be taken from the camera.
Chapter 5: Operation 5.8.2.2 Sarix TI Series Camera User Manual Secondary Stream Expand the Secondary Stream option. The following opens (click take effect; click to revert your changes): for the changes to Figure 5-28: Streaming Window - Day Tab - Secondary Stream The secondary stream option consists of the following parameters: VBR quality factor: 1 is the lowest level. GOP I-frame spacing: Group Of Pictures; how many frames will include an Intra-Frame.
Chapter 5: Operation 5.8.3 Sarix TI Series Camera User Manual General Configuration Tab Select the General Configuration tab. The following opens (click take effect; click to revert your changes): Figure 5-29: Streaming Window - General Configuration Tab The General Configuration tab consists of the following parameters: Enable Authentication: user/password enabled. RTSP Port: the RTSP port.
Chapter 5: Operation 5.9 Sarix TI Series Camera User Manual Image Processing Window The Image Processing window allows changing the video display method, orientation and quality. Click Image Processing. The Image Processing - Thermal tab opens. 5.9.1 Thermal Tab 1. You can: • From the Active Pipeline drop-down list select the pipeline name that is currently active (either Night Vision - NV or EyeQ): NV EYE-Q™ • Click to restart the video streaming. • Click to stop the video streaming.
Chapter 5: Operation Sarix TI Series Camera User Manual 2. Applicable for video processing only: click to revert the entire settings to your local site settings. The following opens: 3. Click OK to approve. 4. Click changes). 5.9.1.1 for the changes to take effect (click to revert your Basic Settings Expand the Basic Settings option.
Chapter 5: Operation Sarix TI Series Camera User Manual The Basic Settings option consists of the following parameters: Black hot: select ("Black Hot") or Clear ("White Hot") the Black Hot checkbox. After , the video image display is changing accordantly (example): clicking White Hot Black Hot Gamma: Gamma level corrections. 5.9.1.2 Signal Processing Settings 1. Expand the Basic Settings option.
Chapter 5: Operation 5.9.1.3 Sarix TI Series Camera User Manual Gain Control Settings Expand the Gain Control option. The following opens (click effect; click to revert your changes): for the changes to take Figure 5-33: Image Processing Window - Thermal Tab - Gain Control Settings The Gain Control option consists of the following parameters: Bad picture pacifier: noise-level deductions. It is recommended to remain with the default value. Gray Levels: the quantity of the gray-levels (up to 200).
Chapter 5: Operation 5.9.1.4 Sarix TI Series Camera User Manual Advanced Settings Expand the Advanced Settings option. The following opens (click take effect; click to revert your changes): for the changes to Figure 5-34: Image Processing Window - Thermal Tab - Advanced Settings The Advanced Settings option consists of the following parameters: Edge Contrast: enhancement of the image contrast. Edge Enhancement: enhancement of the image edges.
Chapter 5: Operation 5.9.1.5 Sarix TI Series Camera User Manual Color Processing Settings 1. Expand the Color Processing option. The following opens (click to take effect; click to revert your changes): for the changes Figure 5-35: Image Processing Window - Thermal Tab - Color Processing Settings 2. Click .
Chapter 5: Operation Sarix TI Series Camera User Manual 3. Select the Allow Region Editing checkbox allowing to define an ROI on the image. The Regions and Sub-Regions areas are enabled. 4. Click the + sign to enable more than one sub-region. 5. Select SubRegion-1 and mark an ROI on the image using the mouse (example): Figure 5-37: Image Processing Window - Histogram Calculation ROI (2 of 3) 6. Click .
Chapter 5: Operation Sarix TI Series Camera User Manual 7. If more than one SubRegion is defined: select SubRegion-2 and mark an ROI on the image using the mouse (example): Figure 5-38: Image Processing Window - Histogram Calculation ROI (3 of 3) 8. Click calculation. to define the selected area as the reference for the . The Sub Region area is highlighted on the image and the 9. Click histogram is automatically calculated and saved. 10.
Chapter 5: Operation 5.9.2 Sarix TI Series Camera User Manual Day Tab 1. You can: • From the Active Pipeline drop-down list select the pipeline name that is currently active (Night Vision - NV, or EyeQ): NV EYE-Q™ • Click to restart the video streaming. • Click to stop the video streaming. • Click to re-start the video streaming.
Chapter 5: Operation Sarix TI Series Camera User Manual 2. Applicable for video processing only: click to revert the entire settings to your local site settings (saved during Section 5.11.1.4: Save As Site). The following opens: 3. Click OK to approve. 4. Click changes). 5.9.2.1 for the changes to take effect (click to revert your Geometry Settings Expand the Geometry Settings option.
Chapter 5: Operation Sarix TI Series Camera User Manual The Geometry Settings option consists of the following parameter: Digital Zoom Level: 5.9.2.2 Misc. Properties Settings Expand the Misc Properties Settings option.
Chapter 5: Operation Sarix TI Series Camera User Manual The Misc. Properties Settings option consists of the following detector parameters: Brightness Color Effects Contrast Focus, Absolute: 0: Automatic, 1: infinity (recommended). Horizontal Flip Hue Saturation Vertical Flip White Balance, Automatic: not active.
Chapter 5: Operation 5.10 Sarix TI Series Camera User Manual Analytics Window The Analytics Window enables detecting and tracking movement within predefined ROIs, as well as for teaching the system where movement typically occurs. 1. Click Analytics. The Analytics window opens (all collapsed): Figure 5-42: Analytics Window (all collapsed) The Analytics window is comprised of three tabs: Regions Tab: enables marking of regios to detect movement (see Section 5.10.1).
Chapter 5: Operation Sarix TI Series Camera User Manual NOTE To enable/disable viewing analytics, click in the top-left corner of the screen to toggle between enable and disable. Click for the changes to take effect (click to revert your changes). 5.10.1 Regions Tab The Regions tab enables marking regions to detect movement. 1. Expand the Regions tab.
Chapter 5: Operation Sarix TI Series Camera User Manual 2. Click the + sign. The following opens (example): Figure 5-44: Analytics Window - Regions Tab - Region Options 3. Click in the Name field and enter a region name. 4. Select region type from the following options: Area – detection is done within a close frame. Fence – detection is done for objects moving towards a predefined line. NOTE Some region options change depending on the type of region selected.
Chapter 5: Operation Sarix TI Series Camera User Manual 5. Select the following parameters: 5-44 • Minimum Detection Size: determines the size and characters of the object to be detected. • • • ONVIF Alert: enabling receiving alerts which conform to ONVIF protocol.
Chapter 5: Operation Sarix TI Series Camera User Manual 6. Click the live image to mark the region frame points. 7. Double click the region starting point to end the region marking. Figure 5-45: Analytics Window - Regions Tab - Area ROI Figure 5-46: Analytics Window - Regions Tab - Fence ROI NOTE The color next to the region name corresponds with the color of the region marked on the image.
Chapter 5: Operation Sarix TI Series Camera User Manual 8. To delete a region definition: select the region (Region-1 or Region-2 in the example) and click the - sign. 9. Click changes). 5.10.2 for the changes to take effect (click to revert your Ignore Regions Tab The Ignore Regions tab enables marking regions in which movement is ignored. Expand the Ignore Regions tab.
Chapter 5: Operation Sarix TI Series Camera User Manual 1. Click the + sign. The following opens (example): Figure 5-48: Analytics Window - Ignore Regions Tab – Ignore Regions ROI (1 of 2) 2. Click the live image to mark the Ignore Region frame points. 3. Double click the region starting point to end the Ignore Region marking.
Chapter 5: Operation Sarix TI Series Camera User Manual 4. To delete an Ignore Region definition: select the ignore region (IgnoreRegion-1 or IgnoreRegion-2 in the example) and click the - sign. 5. Click changes). 5.10.3 for the changes to take effect (click to revert your Learning Tab The Learning tab enables the system to learn the scene and where movement typically occurs. Expand the Learning tab. The following opens: Figure 5-50: Analytics Window - Learning Tab 1.
Chapter 5: Operation Sarix TI Series Camera User Manual NOTE When the Start button is pressed, the following message is displayed on the lower-left corner of the screen. Click OK to close this message. 5.10.4 Analytics Settings Click in the upper-right corner of the screen.
Chapter 5: Operation Sarix TI Series Camera User Manual The Analytics Settings window consists of the following parameters: ActiveBlockPercent: Percentage of the block area that should be active in order to detect movement (default: 70%) BlockSize: minimum block size (default: 8) Draw Region: enabling drawing of region Draw Target Box: enabling frame overlay around the moving target Draw Target Trail: enabling trail showing the path the moving target has taken.
Chapter 5: Operation 5.11 Sarix TI Series Camera User Manual System Window The System Window consists of five tabs: Admin Tab (see Section 5.11.1) Logs Tab (see Section 5.11.2) Date and Time Tab (see Section 5.11.3) File Upload Tab (see Section 5.11.4) User Management Tab (see Section 5.11.5) 5.11.1 Admin Tab Click ADMIN. The following opens: Figure 5-52: System Window - Admin Tab 5.11.1.1 Restart To completely restart the entire system: 1. Click .
Chapter 5: Operation Sarix TI Series Camera User Manual 2. Click OK to approve the system restart. The following opens, stating that the restart process could take a few minutes: Figure 5-54: System Window - Admin Tab - Restart On completion, the following opens prompting that the restart is completed: 5.11.1.2 Archive System Files To archive the entire system files: 1. Click .
Chapter 5: Operation Sarix TI Series Camera User Manual On completion, the following opens prompting to approve the download of the archived file: 2. Click Yes to download the file. The file is downloaded and saved in your \Downloads folder. File name: System-files.tgzx. 5.11.1.3 Save As Site To save the current settings of the camera and the GUI as site defaults: 1. Click . The following opens: Figure 5-56: System Window - Admin Tab - Save As Site Approval 2. Click OK to proceed.
Chapter 5: Operation Sarix TI Series Camera User Manual On completion, the following opens prompting that the site defaults are saved: 5.11.1.4 Export Site To download an archived file that contain the site defaults: 1. Click . The following opens prompting to approve the site defaults download: Figure 5-58: System Window - Admin Tab - Export Site Approval 2. Click Yes to download the file with DHCP, OR: Click No to download the file with a constant IP address.
Chapter 5: Operation Sarix TI Series Camera User Manual 2. Click OK. The following opens, prompting that the site defaults restoration is in process: Figure 5-60: System Window - Admin Tab - Site Defaults On completion, the following opens prompting that the site defaults are saved: 5.11.1.6 Factory Defaults To revert settings to factory defaults: 1. Click .
Chapter 5: Operation Sarix TI Series Camera User Manual 2. Click OK.
Chapter 5: Operation 5.11.2 Sarix TI Series Camera User Manual Logs Tab The Status tab allows downloading data files from the Sarix TI Camera. This is mainly useful when troubleshooting possible Sarix TI Camera malfunctions by Pelco’s technical support team. 1. Click System and select Log Files. The Status tab displays a list of logs (example): Figure 5-63: System Window - Logs Tab 2. To refresh the list click 5-57 .
Chapter 5: Operation 5.11.3 Sarix TI Series Camera User Manual Date and Time Tab CAUTION Time synchronization is extremely important for the ONVIF handshake. If the time is not correctly synchronized, the camera may not connect over ONVIF. The Date and Time tab allows synchronizing of the Sarix TI Camera time and date according to several methods: Click System and select the DATE & TIME tab.
Chapter 5: Operation Sarix TI Series Camera User Manual 5.11.3.1 Synchronizing with Browser Time Select the Synchronize with browser time option. The following opens: Figure 5-65: System Window - Date and Time Tab - Synchronizing with Browser Time 5.11.3.2 Synchronizing with NTP Select the Synchronize with NTP option.
Chapter 5: Operation 5.11.4 Sarix TI Series Camera User Manual File Upload Tab The File Upload tab allows updating your Sarix TI Camera with FM/SW. 1. Click System and select the FILE UPLOAD tab. The File Upload tab opens: Figure 5-67: System Window - File Upload Tab 2. Click format). to browse and select the required FM/SW file (*.tgzx file 3. Click UPLOAD FILE. The uploading process is started. On completion, the RESTART button is valid. 4. Click process. 5.11.
Chapter 5: Operation Sarix TI Series Camera User Manual 5.11.5.1 Adding a User To add a new user: 1. Click . The following opens: Figure 5-69: System Window - User Management Tab - Adding a User 2. Enter the User Name. 3. From the User Role drop-down list select the usage-level of the user: 4. Click 5-61 to validate the changes.
Chapter 5: Operation Sarix TI Series Camera User Manual 5.11.5.2 Editing User Details 1. Select a user and click . Figure 5-70: System Window - User Management Tab - Editing User Details 2. Change the user details. 3. Click 5.12 to validate the changes. Logging Out from the Web GUI 4. Stop any action, currently in process. 5.
Chapter 6: Maintenance 6. Sarix TI Series Camera User Manual Maintenance This chapter provides the Sarix TI Series Camera preventive maintenance instructions. The chapter consists of the following sections: Section 6.1: Visual Inspection Section 6.2: Cleaning 6.1 Visual Inspection 1. Visually inspect the camera and check the physical condition of the camera’s chassis and lens. 2. Check the physical condition of the cable (torn, over-bending, damaged isolation, bent or immersed pins). 6.
Chapter 7: Ordering Information 7. Sarix TI Series Camera User Manual Ordering Information This chapter provides information for purchasing the Sarix TI Series Camera and accessories. The chapter consists of the following sections: 7.1 Ordering Information Table 7-1: 17μ 640x480 17μ 384x288 Lens Type Part Number 14.2mm f/1.2, Athermalized, Fixed Focus TI2614 35mm f/1.2, Athermalized, Fixed Focus TI2635 50mm f/1.2, Athermalized, Fixed Focus TI2650 14.2mm f/1.
Chapter 8: Index 8. Sarix TI Series Camera User Manual Index This chapter provides a list, arranged in alphabetical order, of keywords found throughout this manual.
Chapter 8: Index Sarix TI Series Camera User Manual Maintenance · 6-63 Maintenance · 3-2 Cleaning · 6-63 Scope · 1-12 Visual Inspection · 6-63 Specifications · 2-18 CMOS Camera · 2-20 N Configurations · 2-19 Network Window · 5-15 System Specifications · 2-18 Certificates · 5-19 Thermal Camera · 2-20 HTTPS Connection · 5-17 Status Window · 5-8 IP Address · 5-16 Status Window Overview IP Address - Auto · 5-16 Day Tab · 5-12 Manual DNS Server Address · 5-17 Disable Camera · 5-13 ONVIF Ser
Chapter 8: Index Main Stream · 5-22 Secondary Stream · 5-24 TOC · 1-2 U Unpacking · 4-1 8-67 Sarix TI Series Camera User Manual V Visual Inspection · 6-63
Chapter 8: Index Sarix TI Series Camera User Manual Pelco, Inc. 625 W. Alluvial Ave. Fresno, CA 93711 Tel. +1 559-292-1981 www.pelco.com Pelco, the Pelco logo, and other trademarks associated with Pelco products referred to in this publication are trademarks of Pelco, Inc. or its affiliates. ONVIF and the ONVIF logo are trademarks of ONVIF Inc. All other product names and services are the property of their respective companies. Product specifications and availability are subject to change without notice.