INSTALLATION/OPERATION TXB-V Translator Board C656M-E (4/07)
Contents Important Safety Instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Important Notice. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Regulatory Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Description . . . . . . . . . .
Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Only use attachments/accessories specified by the manufacturer. 6. Installation should be done only by qualified personnel and conform to all local codes. Only use replacement parts recommended by Pelco. The product and/or manual may bear the following marks: This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit.
Regulatory Notices This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. RADIO AND TELEVISION INTERFERENCE This equipment has been tested and found to comply with the limits of a Class B digital device, pursuant to Part 15 of the FCC Rules.
Description The TXB-V translator board allows Vicon® controllers to communicate with Pelco’s ExSite™, Esprit®, and Spectra® systems. After setup, the controller functions the same as a Vicon controller normally would, except as noted in the Operation section on page 21.
Esprit Installation To install the TXB-V translator board in an Esprit system (refer to Figure 1): 1. Turn off power to the Esprit system. 2. Remove the left cover from the pan and tilt. 3. Remove the shorting plug from the 16-pin connector on the Esprit system’s circuit board. 4. Remove the nut and washer from the standoff on the Esprit system’s circuit board. NOTES: • Discard the 6-32 and 4-40 screws and their lock washers; they are not used in the Esprit system. • Save the 16-pin shorting plug.
P3 & P4 JUMPERS P2 UNTERMINATED P2 TERMINATED P2 JUMPER 16-PIN CONNECTOR Figure 2. TXB-V Termination and Baud Rate (Bottom View) 6. Set the baud rate for the TXB-V translator board (from the controller). Use the P3 and P4 jumpers (refer to the following table). Baud P3 600 OFF P4 OFF 4800* ON ON 9600 OFF ON 19.2K ON OFF *Factory default. 7. Install the TXB-V on the Esprit circuit board (refer to Figure 3): a.
9. Reinstall the left cover of the pan and tilt: WARNING: Make sure you seal the unit. Otherwise, moisture could disable or damage the Esprit. a. Properly position the cover and slide it into place. The sides of the cover must fit under the front and back rain guards of the pan and tilt. The top of the cover must seat against the lip of the top gasket. (Refer to Figure 4.) NOT SEALED CORRECT INCORRECT GAP Figure 4. Installing the Esprit Cover 8 b.
TOP GASKET FRONT RAIN GUARD Figure 5. Fastening the Esprit Cover 10. Remove the pan and tilt from the base of the Esprit system. 11. Check the control wiring inside the base of the unit. Refer to the Esprit documentation and the documentation supplied with your controller to make sure the wiring is correct. Vicon Controller Terminal Block J1 Esprit Wire Harness Pin 9 Response Out + White (TX+) Pin 8 Response Out - Black (TX-) Pin 3 Command In + Red (RX+) Pin 2 Command In - Green (RX-) 12.
Spectra III/Spectra IV Installation To install the TXB-V translator board in a Spectra III/Spectra IV Series: 1. Turn off power to the dome system. 2. Remove the lower dome. 3. Remove the dome drive by pressing in the blue and red tabs on the sides of the dome drive. Gently rock the dome drive to release it from the back box. 4. Set the P2 jumper on the TXB-V to the proper termination setting (refer to Figure 6).
6. Install the TXB-V translator board into the back box: a. Open the hinged door to the back box. Push the tab lock towards the back box wall of the unit and open the door (refer to Figure 7). Figure 7. Spectra III/Spectra IV Back Box Interconnect Door b. C656M-E (4/07) Check the wiring to the controller. Refer to the Spectra III/Spectra IV documentation and the documentation supplied with your controller to make sure the wiring is correct.
c. Remove the shorting plug from the 16-pin connector located on the back box circuit board (refer to Figure 8). 6-32 SCREW AND LOCK WASHER REMOVE SHORTING PLUG 16-PIN CONNECTOR STANDOFF Figure 8. Spectra III/Spectra IV Back Box Circuit Board NOTES: • • Discard the 4-40 screw and its lock washer; they are not used in the Spectra III/Spectra IV system. Save the 16-pin shorting plug. Otherwise, the Spectra III/Spectra IV cannot be converted back to a Pelco-controlled system. d.
b. For Spectra III systems, set all SW3 switches on the dome to the OFF position. For Spectra IV systems, set SW2-1 through SW2-8 to the OFF position. SW1 SW3 SW2 SW1 AND SW2 1 2 3 4 5 6 7 8 1 1 2 3 4 5 6 7 8 SW1 SW3 on SW2 on Figure 9. Spectra III Dome Drive DIP Switches Figure 10. Spectra IV Dome Drive DIP Switches 8. Install the dome drive (refer to Figure 11). Line up the blue (A) and red (B) tabs with the blue (A) and red (B) labels. When pushing the tabs in, insert one side, then the other.
Spectra Mini Dome Installation To install the TXB-V translator board in a Spectra Mini dome: NOTE: Installing a TXB-V into a mini dome increases unit height. In surface mount installations, you must cut a hole in the surface to accommodate the TXB-V cover. For an installation template and more information, refer to the Spectra Mini Dome Installation manual. 1. Turn off power to the dome system. 2.
5. Set the P2 jumper on the TXB-V to the proper termination setting (refer to Figure 13). Note the following: • • • • • By default, the P2 jumper is installed in the unterminated position. All TXB-Vs in a daisy chain, except the last unit, must be unterminated. The total wire distance from the Vicon controller to the last TXB-V in a daisy chain must be less than 4,000 ft (1,219 m). A maximum of 10 receivers can be installed on a single daisy chain.
REMOVE SHORTING PLUG Figure 14. Removing the Mini Dome Cover and Shorting Plug c. Insert the TXB-V translator board into the 16-pin connector on the Spectra Mini dome’s circuit board. d. Install the translator board cover that is supplied with the Spectra Mini dome. Figure 15.
8. Check the wiring to the controller. Refer to the Spectra Mini dome documentation and the documentation supplied with your controller to make sure the wiring is correct. Vicon Controller Terminal Block J1 Spectra Mini Dome RJ45-10 Connector Pin 9 Response Out + Pin 6 (TX+) Pin 8 Response Out - Pin 5 (TX-) Pin 3 Command In + Pin 4 (RX+) Pin 2 Command In - Pin 3 (RX-) 9. Refer to the installation manual for the Spectra Mini dome to complete the installation. 10. Apply power to the system.
ExSite Installation To install the TXB-V translator board in an ExSite unit: WARNING: To reduce the risk of ignition of hazardous atmospheres, disconnect the equipment from the supply circuit before opening. 1. Turn off the power to the ExSite system. WARNING: Total weight of the pan and tilt component is 55 lb (25 kg). Use caution when lifting and assembling the pan and tilt component on the power module. It is recommended that nonslip gloves be worn during installation or removal. 2.
• To unterminate a TXB-V, remove the P2 jumper from the TXB-V and place it over one pin for storage. NOTE: When combining Pelco and Vicon receivers in the same system, refer to the Vicon manual for proper RS-485 configuration of the Vicon receiver(s). P3 & P4 JUMPERS P2 UNTERMINATED P2 TERMINATED P2 JUMPER 16-PIN CONNECTOR Figure 18. TXB-V Termination and Baud Rate (Bottom View) 4. Set the baud rate for the TXB-V translator board (from the controller).
16-PIN CONNECTOR SW1 SW3 Figure 19. Installing the TXB-V into the ExSite 6. Check the wiring to the controller. Refer to the ExSite documentation and the documentation supplied with your controller to make sure the wiring is correct. Vicon Controller Terminal Block J1 ExSite Wire Harness Pin 9 Response Out + White/Orange (TX+) Pin 8 Response Out - White/Blue (TX-) Pin 3 Command In + Red (RX+) Pin 2 Command In - Green (RX-) 7.
Operation Set preset 94 to access the camera menus. Press Iris Open to select menu items. The following table shows how the Vicon keyboard relates to the Pelco translator. Refer to your Vicon documentation for operating instructions.
TXB-V ZONE PROGRAMMING PROCEDURE A zone is a pan area, defined by a left and right limit, on the 360-degree pan plane. To program a zone using a Vicon controller (refer to the manual supplied with the controller): Step 1. Set left zone limit. Procedure a. Position the Pelco unit at the left limit of the zone. b. Issue the zone start command (PRG 8# PRESET) for the zone number being programmed; # is a number between 0 and 7 that represents zones 1 through 8. 2. Set right zone limit. a.
Troubleshooting Symptom Possible Cause Suggested Remedy No video is displayed. Power is not connected to the Pelco unit. Check the power connector. Video cable is not connected to the Pelco unit. Check the video connector. Translator board is not inserted properly. Reinstall the translator board. Make sure the pins on the board are inserted correctly. Pelco unit information (model, firmware, Pelco P and D addresses, and communication settings) does not appear after the configuration cycle.
Appendix Table A.
Table A.
Table A.
Table A.
Table A.
Table A.
Table A.
PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Exceptions to this warranty are as noted below: • Five years on fiber optic products and TW3000 Series unshielded twisted pair transmission products. • Three years on Spectra® IV products. • Three years on Genex® Series products (multiplexers, server, and keyboard).