Spec Sheet
TECHNICAL SPECIFICATIONS
VIDEOXPERT PLAYER
The VideoXpert player decrypts, validates, and plays-back secured exports from VideoXpert. You can download the player directly from VideoXpert along with an
exported video file or you can download it from Pelco.com.
These are the minimum system requirements for non-VideoXpert machines running the VideoXpert player:
Hardware Requirements Dual Core i5 2.67 GHZ
4 GB RAM
200+ GB of free HDD space or more
GPU that supports OpenGL 3.0 or higher
1024 x 768 or higher screen resolution
100/1000 Ethernet Network Interface Card
Sound Card
Software Requirements Windows 7 Pro or Ultimate 64 bit or higher
.NET 4.6.1 or higher
OpenGL 3.0 or higher
Direct3D 9 or higher
POWER
Power Server Flex Server Eco Server Workstation
Input 100–240 VAC, autoranging, 50/60 Hz
90-264 VAC, 47 Hz - 63 Hz, 3
A / 1.5 A
Supply
Internal 450 W (Bronze), Dual
Hot Swappable 495 W
(Platinum)
Internal 350 W (Bronze) Internal 290 W (Bronze) Internal 180W
NOTE: This system is also designed to be connected to IT power systems with a phase-to-
phase voltage not exceeding 230 V.
Consumption
1871 BTU/hr maximum (450
W power supply), 1908
BTU/hr maximum (495 W
power supply)
1357 BTU/hr maximum (350
W power supply)
989 BTU/hr maximum (290 W
power supply)
614 BTU/hr maximum (180 W
power supply)
Note: Heat dissipation is calculated by using the power supply wattage rating.
ENVIRONMENTAL
Power Server Flex Server Eco Server Workstation
Operating Temperature
10°C to 35°C (50°F to 95°F) with no direct sunlight on the equipment. 0°C to 35°C (32°F to 95°F)
Note: Maximum temperature is reduced by 1°C/300 m (33.8°F/984.25 ft) above 950 m
(3,117 ft)
Non-Operating Temperature –40°C to 65°C (–40°F to 149°F)
–40°C to 65°C (–40°F to
149°F)
Operating Relative Humidity
5% to 95% RH with 33°C (91°F) maximum dew point. Atmosphere must be non-condensing
at all times.
10 % to 90 % (non
condensing)
Non-Operating Relative Humidity 10% to 80% Relative Humidity with 29°C (84.2°F) maximum dew point.
5 % to 95 % (non
condensing)
Operating Altitude Maximum of 3048 m (10,000 ft)
–15.2 m to 3048 m (–50 to
10,000 ft)
Operating Vibration 0.26 Grms at 5 Hz to 350 Hz (operation orientations) 0.66 GRMS
PHYSICAL
Power Server Flex Server Eco Server Workstation
Dimensions (D x W x H)
64.8 x 43.4 x 8.68 cm
(26.3 x 17.1 x 3.4 in)
without rack ears
55.86 x 21.8 x 43.03 cm
(22.77 x 8.58 x 17.04 in)
36 x 17.5 x 43.5 cm
(14.17 x 6.89 x 17.12 in)
29.0 x 29.2 x 9.26 cm
(11.4 x 11.5 x 3.6 in)
Rack Mounting (RU) 2 RU N/A
Unit Weight
28.2 kg (62 lb) [varies by
configuration]
26.02 kg (57.32 lb) [varies by
configuration]
11.1 kg (24.47 lb) [varies by
configuration]
5.14 kg (11.42 lb) [varies by
configuration]