IR850, IR940 & WLED LED ILLUMINATORS C3934M (9/13)
Contents Important Safety Instructions............................................................................. 3 Important Notices Regulatory Notices..................................................................................... 4 Radio and Television Interference.............................................................. 4 Installation Steps – Quick Guide........................................................................ 5 Complete Set up and Installation.................................
Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water. 6. Clean only with dry cloth. 7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. 8. Only use attachments/accessories specified by the manufacturer. 9. Refer all servicing to qualified service personnel.
Important Notices REGULATORY NOTICES This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. RADIO AND TELEVISION INTERFERENCE This equipment has been tested and found to comply with the limits of a Class B digital device, pursuant to Part 15 of the FCC Rules.
Installation Steps – Quick Guide 1. IR850, IR940 & WLED Illuminators are factory set and delivered with a 35˚ beam width. To alter to 10˚, simply remove Interchangeable Diffuser System (IDS) lens. To alter to 60˚, replace with the other IDS lens supplied. See detailed instructions later in this document. 2. Mount Illuminator. 3. Connect the Illuminator to a properly rated low voltage power supply (12-24V AC/DC). 4.
Complete Set up and Installation Step 1. Select different beam angle – if required All IR850, IR940 & WLED illuminators are set and delivered with a 35˚ beam width angle. To alter to 10˚, simply remove Interchangeable Diffuser System (IDS) lens. To alter to 60˚, replace with additional IDS lens supplied. Other angle IDS lenses are available to order: 80˚ and 120˚. All IDS lenses will be clearly marked with the angle which they will produce when inserted into IR850, IR940 or WLED illuminator.
Step 2. Mounting Illuminator All IR850, IR940 & WLED illuminators are delivered as standard with the bracket at the bottom of the unit. This can be moved to the top of the unit if required. 1 2 3 Position illuminator adjacent to camera and point towards scene (Optional night set-up for optimum image performance) Adjust vertical position of lamp to ensure full field of view illuminated Tighten all fixings Step 3.
Remote Controller Optional Accessory Photocell Adjust To select 3 different photocell sensitivity levels to accommodate different operational requirements Power Select Timer Settings Quick and easy selection of 5 accurately defined power settings.
LED Feedback System In Programming Mode Solid Green status LED indicates unit has power applied. FLASHING GREEN status LED indicates a problem with the remote control IR receiver. The maximum remote operating distance is 8m (26ft). Flashing Amber status LED indicates unit is in programming mode. Solid Amber indicates unit receiving valid command from remote control device.
Standard Brackets (not to scale, dimensions rounded to nearest cm) Small 5.2cm (2”) 4.7 (1. cm 8”) cm 5.1 2”) ( Medium 5.6cm (2.2”) 7.2 (2. cm 8”) cm 5.3 .1”) (2 Large 5.3cm (2.1”) 10 . (4. 4cm 1”) 10 www.pelco.com cm 5.3 .
Optional Mounting Bracket LBKT-LED Bracket for mounting all PELCO LED illuminators to flat surface or wall Mechanical Bracket attachment 8.5mm hole diameter (see drawings below) Lamp Mounting Options Once illuminator(s) has been mounted to LBKT, please ensure to check alignment. Top Mount Bottom Mount Optional Mounting Bracket Dimension Drawings (not to scale, dimensions rounded to nearest cm) m 6c . R1 (0 ) 2” .6 cm ∅ 0.85cm (0.33”) 5 0.8 ”) 33 (0. 0.8cm (0.31”) 0.5cm (0.19”) 8.9cm (3.
Optional Interchangeable Diffuser System LENSPK–LED Each LENSPK comes with x2 IDS Lenses - 80°x30° and 120°x50° LENSPKS-LED (Small) LENSPKM-LED (Medium) LENSPKL-LED (Large) All Pelco LED illuminators are factory set and delivered with a 35˚ beam width angle. To alter to 10˚, simply remove Interchangeable Diffuser System (IDS) lens. To alter to 60˚, replace with other IDS lens supplied. Other angle IDS lenses are available to order: 80˚ and 120˚.
Specifications Infra-Red Series & White-Light Series Large IR Large WL Medium IR Medium WL Small IR 220m (10˚) 150m (10˚) 120m (10˚) Max.
Illuminator Dimension Drawings Large Units (IR850L-220, IR940L-110 and WLEDL-150) 6.82cm (2.7”) 13.5cm (5.3”) 20.05cm (7.9”) 18cm (7.1”) 7.15cm Power cable (Not to scale) 3cm (2.8”) (1.2”) 9.47cm (3.7”) Ø0.85cm (0.3”) 14 www.pelco.
Medium Units (IR850M-120, IR940M-60 and WLEDM-90) 6.6cm (2.6”) 10cm (3.9”) 13.5cm (5.3”) 15.82cm (6.2”) 4cm (1.6”) Power cable (Not to scale) 3cm (1.2”) 9.47cm (3.7”) Ø0.65cm (0.3”) C3934M (9/13) www.pelco.
Small Units (IR850S-65, IR940S-30 and WLEDS-50) 7.5cm (3.0”) 6.41cm (2.5”) 11.95cm (4.7”) 10cm (3.9”) Power cable (Not to scale) 3cm (1.2”) 1.4cm (0.6”) 9.3cm (3.7”) Ø0.65cm (0.3”) 16 www.pelco.
Troubleshooting Guide Ensure all tests are undertaken by qualified personnel and ensure safe working practices are followed at all times. Step 1: Basics • Check polarity of Lamp connection Red= +, Black= Gnd • Ensure power is 12-24V AC or DC • Ensure telemetry wires are shorted or closed contact input (zero volt) is applied. • Check photocell is working. Cover photocell fully, light should turn on.
Programming mode – (AMBER LED flashes 1 second on/1 second off) • Solid GREEN - Power Applied • Flashing GREEN - Remote IR receiver problem • Solid RED - Internal LED Fault Detected • Flashing RED - Voltage supply problem detected - Please note – once the voltage problem has been corrected, the user must disable remote control set-up or power the unit on and off to stop the red status LED flashing.
Step 4: Call Pelco for further assistance If the instructions provided fail to solve your problem, contact Pelco Product Support at 1-800-289-9100 (USA and Canada) or +1-559-292-1981 (international) for assistance. Be sure to have the serial number available when calling. Do not try to repair the unit yourself. Leave maintenance and repairs to qualified technical personnel only. C3934M (9/13) www.pelco.
Pelco by Schneider Electric 3500 Pelco Way, Clovis, California 93612-5699 United States USA & Canada Tel (800) 289-9100 Fax (800) 289-9150 International Tel +1 (559) 292-1981 Fax +1 (559) 348-1120 www.pelco.com www.pelco.