User manual

How to deactivate the acoustic signals
1. Press the on/off button to activate the
appliance. Make sure that the appliance
is in setting mode. Refer to ‘SETTING
AND STARTING A PROGRAMME’.
2. Press and hold function buttons (B) and
(C) at the same time until the indicators
of function buttons (A), (B) and (C) start
to flash.
3. Press function button (C),
The indicators of function buttons (A)
and (B) go off.
The indicator of function button (C)
continues to flash.
The end indicator comes on.
4. Press function button (C). The end indi-
cator goes off, the acoustic signals are
deactivated.
5. Deactivate the appliance to confirm the
setting.
How to activate the acoustic signals
1. Refer to ‘How to deactivate the acoustic
signals’, step (1) through (3).
2. Press function button (C),
The indicators of function buttons (A)
and (B) go off.
The indicator of function button (C)
continues to flash.
The end indicator is off.
3. Press function button (C). The end indi-
cator comes on, the acoustic signals
are active.
4. Deactivate the appliance to confirm the
setting.
BEFORE FIRST USE
1. Make sure that the set level of the water
softener agrees with the water hardness
in your area. If not, adjust the water
softener. Contact your local water au-
thority to know the water hardness in
your area.
2. Fill the salt container.
3. Fill the rinse aid dispenser.
4. Open the water tap.
5. Processing residues can stay in the ap-
pliance. Start a programme to remove
them. Do not use detergent and do not
load the baskets.
If you use the combi detergent tablets,
activate the multitab option.
Adjusting the water softener
Water hardness
Water softener
adjustment
German
degrees
(°dH)
French
degrees
(°fH)
mmol/l Clarke
degrees
Manual Elec-
tronic
51 - 70 91 - 125 9.1 - 12.5 64 - 88
2
1)
10
43 - 50 76 - 90 7.6 - 9.0 53 - 63
2
1)
9
37 - 42 65 - 75 6.5 - 7.5 46 - 52
2
1)
8
29 - 36 51 - 64 5.1 - 6.4 36 - 45
2
1)
7
23 - 28 40 - 50 4.0 - 5.0 28 - 35
2
1)
6
19 - 22 33 - 39 3.3 - 3.9 23 - 27
2
1)
5
1)
15 - 18 26 - 32 2.6 - 3.2 18 - 22 1 4
11 - 14 19 - 25 1.9 - 2.5 13 - 17 1 3
4 - 10 7 - 18 0.7 - 1.8 5 - 12 1 2
< 4 < 7 < 0.7 < 5
1
2)
1
2)
1) Factory position.
2) Do not use salt at this level.
19