Operation Manual

INSTALLATION35
Installation
General
The fitting of the appliance should only be
carried out by a registered Corgi gas fitter.
The appliance is not connected to the flue gas
outlet channel.
Electrical connection 230 V - 50 Hz.
The electrical connection must comply
with national and local regulations. For the
Netherlands this includes the NEN 1010
amongst other standards.
Wall socket and plug must be accessible at
all times.
The appliance should always be earthed. Use
good quality cable for connecting e.g. H05RRF,
1,5 or 2,5 mm
2
, with 3 cores, depending on the
regulations.
With following colour code:
brown = phase L
blue = N
green/yellow = earth (
)
The cable must have a plug suitable for a
nominal load of at least 15 A.
If you want to make a fixed connection, ensure
that a multi-pole switch with a distance
between contacts of 3 mm is installed in the
supply cable.
The cable must not touch any hot parts
(>70 ºC),
Replacing the cable
If the cable becomes damaged, replace it as
follows:
Open the junction box (see fig. 13).
Unscrew screw “A” from the pull relief.
Unscrew the screws from the terminals
and remove the cable.
Place a new cable of the same type and
length. To connect the cable, see the
colour code for “Electrical connection”.
Secure the cable with screw ”A” of the
pull relief and close the junction box.
fig.13