Operation Manual
INSTALLATION35
Installation
General
The fitting of the appliance should only be
carried out by a registered Corgi gas fitter.
The appliance is not connected to the flue gas
outlet channel.
Electrical connection 230 V - 50 Hz.
■ The electrical connection must comply
with national and local regulations. For the
Netherlands this includes the NEN 1010
amongst other standards.
■ Wall socket and plug must be accessible at
all times.
The appliance should always be earthed. Use
good quality cable for connecting e.g. H05RRF,
1,5 or 2,5 mm
2
, with 3 cores, depending on the
regulations.
With following colour code:
brown = phase L
blue = N
green/yellow = earth (
)
The cable must have a plug suitable for a
nominal load of at least 15 A.
If you want to make a fixed connection, ensure
that a multi-pole switch with a distance
between contacts of 3 mm is installed in the
supply cable.
The cable must not touch any hot parts
(>70 ºC),
Replacing the cable
If the cable becomes damaged, replace it as
follows:
■ Open the junction box (see fig. 13).
■ Unscrew screw “A” from the pull relief.
■ Unscrew the screws from the terminals
and remove the cable.
■ Place a new cable of the same type and
length. To connect the cable, see the
colour code for “Electrical connection”.
■ Secure the cable with screw ”A” of the
pull relief and close the junction box.
fig.13