Operation Manual

INSTALLATION37
Please note:
When the oven is placed next to a high
cupboard or another wall made of flammable
material the minimum distance between the
cooker and walls should be at least 50 mm.
The minimum distance between the hotplate
and a cooker hood installed above it should
be at least 650 mm.
If the oven is installed in a kitchen unit,
the minimum space must be observed as
indicated in fig. 15.
If the oven is to be installed between kitchen
units, the panelling of the adjacent kitchen
units must be able to withstand temperatures
of at least 90 °C.
Levelling
The height of the oven can be adjusted with
the adjustable feet (see figure 16).
If you want to place the oven on a raised
surface, ensure that the unit cannot slide off.
Before using the appliance for the first
time check the connections using water
and washing-up liquid to ensure that there
are no gas leaks.
After installation check that the appliance
and the burners are working properly. The
gas flames should be regular and stable
when full on and the burners should not go
out when turned to the lowest setting.
fig. 15
fig. 16
fig. 14