Operation Manual
EN 30
Please note!
After installation of the device, check whether the burners work properly.
The flame pattern should be regular and stable on the high setting, and
the burners must not go out on low.
Measurements
Technical data
The rating label (on the inside of the storage compartement) of the
appliance indicates the total nominal load, the required voltage and the
frequency.
This appliance meets all relevant CE guidelines.
Connection 230-240 V~ - 50/60 Hz
Power output 3352 W
External dimensions (mm)
Width 900
Height 890-940
Depth 600/1000 with open door
Gas information
Burner Gas
Operating pressure mbar
Normal (1.65 kW)
G25/G25.3
25
High (2.8 kW)
G25/G25.3
25
Simmer (1 kW)
G25/G25.3
25
Wok (4 kW)
G25/G25.3
25
INSTALLATION
900
60
600
890-
940
60