Use and Care Guide

1. Unpackage and account for all items before starting installation.
2. Determine location and water flow direction for system
3. Install covers onto bracket orientating the INLET and OUTLET
correctly. Use 4 bolts and washers in each cover to attach.
Assembly
A. (8) Machine Bolts & Washers
B. (3) Lag Bolts & Washers
C. (1) Spanner Wrench
D. (2) 20” Housings w/Covers
E. (1) Chloramine Cartridge
F. (1) Fluoride Cartridge
G. (1) Mounting Bracket
H. (2) Decals
I. (1) Silicone Grease
Items Included:
MODEL: PC200-F
Specications:
Rated Service Flow 5 gpm
Minimum Working
Pressure
25 psi
Maximum Working
Pressure
80 psi
Operating
Temperatures
36°F - 120°F
PH Range 6 - 11
Fluoride Cartridge
(Install as shown)
Housing Cover
Housings
Stand Pipe
O-Ring
EZC-CF_2017-3_R-A
© Pelican Water Systems 3060 Performance Circle • Deland, FL • 32724 877-842-1635 www.pelicanwater.com
A
E
B
C
D
F
G H
I
Drains
Fig. A