Instructions / Assembly

6
Pelican Water Systems | www.PelicanWater.com | 877-842-1635
®
3-Stage Drinking Water Filter
1. Locate and turn o the angle stop valve on the cold water line feeding the sink. This valve
will usually be located under the sink on the pipe coming out of the wall.
2. When the angle stop valve is closed, relieve pressure in the line by momentarily opening
the cold water tap on the sink.
3. Disconnect the cold water faucet feed line at the angle stop valve.
4. Install the feed valve assembly into the angle stop.
5. Firmly press the green 1/4” tubing into the 1/4" connector on the feed valve assembly.
6. Connect the cold water faucet feed line into the feed valve assembly.
7. Make sure the small shut-o valve on the feed valve assembly is closed. Turn on the feed
water connecon valve. Check for leaks.
8. Aach the small feed valve warning tag from the parts bag to the feed valve.
9. Aach the Shuto Warning label to the system so that it is directly visible. Fill out the
Date of Installaon label and aach to the side of the system.
Feed Connecon
Adapter
Shut-o valve
Fig. 1
Note: The feed valve
adapter may be
congured to t either
a 3/8" or 1/2" angle
stop connecon by
changing the locaon
of the adapter.
Angle stop