Instructions / Assembly
1. Unpackage and account for all items before starting installation.
2. Unscrew both Covers from each of the Housings
3. Wrap Teon tape around both ends of the 1” Brass Hex Nipple.
4. Thread nipple into the OUTLET of one of the covers and tighten with a wrench.
5. Thread the second cover INLET side to the nipple turning until tight and
orientated correctly.
6. Install the Brass Threaded Plug to the rst cover threaded hole using Teon tape to
seal the threads. Tighten with a wrench.
7. Install the Pressure Gauge to the second cover using Teon tape to seal the
threads. Tighten with a wrench making sure to orientate the pressure gauge to
the front for reading.
8. Install covers onto bracket orientating the INLET and OUTLET correctly.
Use 4 bolts and washers in each cover to attach.
Assembly
A. (8) Bolts & Washers
B. (1) Spanner Wrench
C. (1) 1” Brass Hex Nipple
D. (1) Pressure Gauge
E. (1) Brass Threaded Plug
F. (2) 20” Housings w/Covers
G. (1) Sediment Cartridge
H. (1) Chlorine Cartridge
I. (1) Mounting Bracket
Items Included:
Specications:
Rated Service Flow 5 gpm
Minimum Working
Pressure
25 psi
Maximum Working
Pressure
80 psi
Operating
Temperatures
36°F - 120°F
PH Range 6 - 11
A
C
E
G H
B
D
F
I
Chlorine Cartridge
Housing Cover
Housing
Stand Pipe
O-Rings
PRC_2016-3_R-A