Instructions / Assembly
13
Pelican Water Systems
877-842-1635, www.pelicanwater.com
Maintenance
Cartridge Replacement
1. Close the small shut-o valve on the feed valve assembly.
2. Close the tank shut-o valve.
3. Open the dispensing faucet to relieve system pressure. Close dispensing faucet when ow has stopped.
4. Remove the cover from the front of the system. Remove the retaining clip. Pull the cartridge o the system evenly at
top and boom. Dispose of used cartridge.
6. Install the new cartridge, rocking gently from side to side as necessary unl the cartridge tubes are properly engaged in
the unit connectors. Install the retaining clip, ensuring the slide locks snap into place in the slots. If the clip does not snap
easily into place through the slots it means the cartridge is not fully inserted into the connectors. Press the top or boom of
the cartridge to engage the connector so that it snaps fully into place. Failure to properly install the retaining clip will result
in accidental leaks and ooding.
7. Open the small shut-o valve on the feed valve assembly. Open the dispensing faucet.
8. Close dispensing faucet aer water starts running.
9. Observe system for any leaks, especially at newly re placed cartridge.
10. Open the tank shut-o valve.
11. The system should be ushed at least once as described above under Secon 8.
Post Filter Replacement
1. Close the small shut-o valve on the feed valve assembly.
2. Close the tank shut-o valve.
3. Open the dispensing faucet.
4. Close the dispensing faucet when the water stops owing.
5. Locate the inline lter on the faucet line.
6. Remove the tubing by depressing the collet towards the lter and pulling the blue tubing from the lter.
7. Remove the other side of the blue tubing as described above.
8. Reverse the above steps to install the new inline lter, making sure that the tubing is pressed in as far as possible.
9. Open the small shut-o valve on the feed valve assembly. Observe system for any leaks, especially at newly re placed
cartridge.
10. Open the tank shut-o valve.
11. The system should be ushed at least once as described in System Acvaon and Flushing.