Performance Data Sheet
System Performance
This system has been tested according to NSF/ANSI 58 for reducon of the substances listed below. The concentraon of
the indicated substances in water leaving the system was reduced to a concentraon less than or equal to the permissible
limit for water leaving the system, as specied in NSF/ANSI 58. Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfecon before or aer the system. Systems cered for cyst reducon may be used
on disinfected water that may contain lterable cysts.
This system has been tested for the treatment of water containing pentavalent arsenic (also known as AS(V), As
+5
, or ar-
senate) at concentraons of 50 ppb. This system reduces pentavalent arsenic, but may not reduce other forms of arsenic.
This system is to be used on water supplies containing a detectable free chlorine residual at the system outlet or on water
supplies that have been demonstrated to contain only pentavalent arsenic. Treatment with chloramine (combined chlorine)
is not sucient to ensure complete conversion of trivalent arsenic to pentavalent arsenic. Please see the Arsenic Facts sec-
on of the Performance Data Sheet for further informaon.
Tesng was performed under standard laboratory condions, actual performance may vary. Incoming water must be free of
potenal membrane foulants such as Iron, Hydrogen Sulde and Manganese. Eciency rang means the percentage of the
inuent water to the system that is available to the user as reverse osmosis treated water under operang condions that
approximate typical daily usage. Recovery rang means the percentage of the inuent water that is available to the user as
reverse osmosis treated water when the system is operated without a storage tank or when the storage tank is bypassed.
Model Number: PRO-RO Producon Rate: 55.30 L/d (14.61 gpd)
Recovery: 26.76% Eciency: 15.82%
Temperature: 4°C - 38°C (40°F - 100°F) Pressure: 2.81 - 5.62 kg/cm
2
(40-80 psi)
Inuent Challenge
Concentraon
Maximum Allowable
Concentraon
Average Percent
Reducon
Arsenic (pentavalent) 50 ppb 10 ppb 97.8
Cysts Minimum 50,000/mL 110 #/mL >99.99
Fluoride 8.0 mL ± 10% 1.5 mL 96.3
Lead 0.15 mL ± 25% 0.010 mL 98.0
TDS (Total Dissolved Solids) 740 187 mL 96.5
System Maintenance
This reverse osmosis system contains a replaceable component crical to the eciency of the system. Replacement of the
reverse osmosis component should be with one of idencal specicaons, as dened by the manufacturer, to ensure the
same eciency and contaminant reducon performance.