Instructions / Assembly

8
Pelican Water Systems
877-842-1635, www.pelicanwater.com
Dimensions and Weight
Pressure 40-80 psi (275 kPa - 552 kPa)
Temp 40°F - 100°F (4°C - 38°C)
TDS <2000 mg/L
Chlorine <1.0 mg/L
Turbidity <1 NTU
SDI <5
pH 4-8
Performance Specicaons
Feed water must be potable, municipal water. Must
be free of potenal membrane foulants such as Iron,
Hydrogen Sulde and Manganese.
Membrane Producon 50 GPD
System
Producon 14.61GPD
TDS Rejecon 96.5%
Recovery
1
26.76%
System tested at 50 psig, 750ppm TDS at 77°F.
1
The percentage of the feed water available
as reverse osmosis treated water under
normal operang condions.
Feed Water Requirements
System Specicaons
Do not use with water that is microbiologically unsafe or of unknown quality
without adequate disinfecon before or aer the system.
This system has been designed for installaon by a licensed professional such as a contractor or plumber. Proper compleon of this installa-
on will require basic familiarity with standard sink plumbing and proper use of common hand and power tools. Improperly installed systems
could result in water damage due to leaks or ooding.
A. Product water storage tank
B. Tank valve
C. Tank tubing (3/8” white)
D. Air-gap faucet
E. Drain connecon assembly
F. Drain tubing (3/8” white)
G. Quick connect ng
H. Drain tubing (1/4” black)
I. Faucet tubing (3/8” blue)
J. Four-stage desalinator
K. Feed water tubing (1/4” green)
L. Feed valve assembly (with adapter and
shut-o valve).
M. Two-stage remineralizing post-lter
A
B
J
E
F
G
D
K
L
M
I
H
C (not shown)
(behind cover)
System Dimensions
9.72” W x 13.75” D x 15.38” H