Whole House Salt Free Water Softener/Conditioner Tank Installation
1. Level the Pelican Whole House Salt Free Water Softener.
Notice:
If the tank is not level, lift the tank straight up 6 inches and tap it on the ground until the tank stands
vertical. The bottom of the tank is round and the boot allows the tank to stand upright.
Figure 5
2. Determine the size and material of your incoming water supply line from the Pre-Filter System and
choose the appropriate plumbing required to adapt to the 1” Male NPT Assembly.
CAUTION:
Do not over-tighten any of the fittings during installation.
Table 2: Bypass Valve Fittings
Note: The fitting below is designed with a ¼
" give to allow for proper pipe alignment. It will not leak and
is intended to have some flexibility.
3. Install the fitting onto the upflow and downflow inlet sides of the Bypass Valve. Follow the diagram
supplied with the fitting.
4. Connect the incoming water supply from the to the fitting on the upflow inlet side of the Bypass
Valve.
5. Connect the outgoing water supply to the downflow inlet side of the Bypass Valve.
Part Description Qty.
1" Plastic Male NPT Assembly:
V3007-04 WS1 Fitting 1" Plastic Male NPT
Assembly (2): O-Rings (2), Split Rings
(2), and Connectors (2)
1
bag
UPFLOW
INLET
DOWNFLOW
INLET
T
Pre-Filter
Incoming
Water
Supply
PVC Fitting*
Bypass
1" NPT Assembly
Valve
Outgoing
ater to
House
W
*Customer supplied,
choose appropriate connection
Salt Free Water
Softener/Conditioner