Installation
Sediment Filter Assembly
Figure 5
Sediment F
ilter Installation
Figure 6
Notice:
The Sediment Filter Housing comes with a 1” threaded female inlet/outlet and will require additional
fittings to adapt to your plumbing. A shut-off valve is recommended prior to the Sediment Filter System.
Sediment Filter Cover
Sediment Filter
O-Ring
Stand Pipe
Blue Filter Housing
Top View Filter
Blue Filter Housing
Inlet Water
Supply
Mounting
Bracket
1. Unscrew the cover from the Blue Filter Housing.
2. Remove the plastic covering from the Sediment Filter.
3. Place the Sediment
Filter onto the Stand Pipe in the Blue Filter Housing
and set aside.
1. Shut off the water.
2. Attach the Filter
Cover to the Mounting Bracket using the supplied Bolt
Head Screws and
Washers. Make sure to properly orientate the IN and OUT to match your flow pattern.
3. Attach the Mounting Bracket to the wall using the supplied Phillips Head Screws.
4. Hand tighten the Blue Filter Housing and then using the supplied Filter Wrench lightly snug
the housing making sure not to over-tighten. (counter clockwise).
5. Determine the size of your inlet water supply line.
Teflon Tape and/or Thread
seal paste is recommended