Full Product Manual

Pelican PSE1800/PSE2000 Premium Whole House Water Filter
& Salt Free Water Softener/Conditioner Combo
© 2018 Enviro Water Solutions, LLC
3060 Performance Circle, Suite 2, DeLand, FL 32724
PSE1800-2000 Rev P
Page 8
www.pelicanwater.com
(877) 842-1635
Water Filter - Carbon Flush
!IMPORTANT!
Do not perform the Carbon Flush until the Carbon Soak process is complete.
Notice:
Water will flow out of the outlet side of the Bypass Valve during this process. Be sure you perform this
series of steps in a location suitable for water flow.
Figure 4
1. Reattach the garden hose to the Hose Bib Assembly.
2. Slowly turn on the water 1/4 turn.
3. Run water through the inlet side of the Bypass Valve for 30 minutes to expel the carbon fines.
4. Turn off the water.
5. Remove the Hose Bib Assembly from the inlet side and attach it to the outlet side of the Bypass
Valve.
6. Slowly, fully open the hose spigot.
7. Run the water through the outlet side for 3 minutes to reset the carbon.
8. Turn off the water.
9. Remove the Hose Bib Assembly from the Bypass Valve and disconnect the garden hose.
Note: Please save the Hose Bib Assembly as this will be used in the future for the carbon
exchange.
Water
Whole House Water Filter
Garden
Hose
Hose Bib
Assembly
INLET
OUTLET
INLET
Water
Whole House Water Filter
Garden
Hose
Hose Bib
Assembly
OUTLET
Carbon Reset
Carbon Flush