Use And Care Manual

Page 8
NOTE
When CONTINUOUS mode function is
turned on, set humidity is automatic
and cannot be changed manually.
(TURBO) Button
Control the Turbo speed. Press to select
either Turbo or normal fan speed. Set
the Turbo control to high for maximum
moisture removal. When room humidity is
at your preferred level, it is advised to turn
off Turbo speed.
(TIMER) Button
Starts the Timer ON and Timer OFF
function setting.
Up/Down Buttons (
/ )
Humidity Set Control Buttons
The humidity level can be set within a
range of 35% RH (Relative Humidity)
to 85% RH (Relative Humidity) in 5%
increments.
For drier air, press the
button and set
to a lower value (%).
For damper air, press the
button and
set a higher value (%).
the unit and plug it back in. If error
persists, contact Customer Service.
ES - Tube Temperature sensor of the
evaporator error - Unplug the unit
and plug it back in. If error persists,
contact Customer Service.
P2 - Bucket is full or bucket is not in right
position - Empty the bucket and
replace it in the right position. (only
available for the unit with no pump
feature.)
Operating
Instructions
(COMFORT) Button
Press to activate the COMFORT
dehumidifying operation. The dehumidifier
will automatically set to a preset humidity
and fan level. To exit comfort mode, adjust
the humidity to desired level.
(FILTER) Button
This feature is a reminder to clean the Air
Filter for more efficient operation. The LED
(light) will
flash
after 250 hours of
operation. To reset after cleaning the filter,
press the Filter button and the light will go
off. The 250 hour counter will reset.
(Cont.) Button
Press to activate the continuous
dehumidifying operation.
NOTE
M
a
ke sure the p
ump dr
ain hos
e is
in
stalled in
to th
e unit and
the
continu
ou
s d
rain hose is removed from
the unit before the pump operation is
activated. When the bucket is full, the
pump starts to work. Refer to the next
pages for removing the collected
water. Do not use this operation when
the outdoor temperature is equal to or
less than 0°C (32°F).
TIMER Set Control Buttons
Use the and key butto
ns to set
the Timer ON or Timer OFF from 0 to
24 hours.
ION Button(on some models)
Press to activate the ionizer. Ions are
automatically generated by ionization.
The ions deactivate the airborne
chemical vapors and dust particles. Press
it again to stop the function.
(POWER) Button
Press to turn the dehumidifier on and off.
LED Display
Shows the set % humidity level from 35%
to 85% or auto start/stop time (0 ~ 24)
while setting, then shows the actual (+/- 5%
accuracy) room % humidity level in a range
of 30% RH (Relative Humidity) to 90% RH
(Relative Humidity).
Error Codes and Protection Code:
AS - Humidity sensor error - Unplug