Installation Instructions

Operating
Instructions
Control Panel Features
Mode button
Selects the desired operating mode.
Each time you press the button, a mode
is selected in a sequence that goes from
COOL, FAN and DRY. The mode light
illuminates and indicates the selected
mode.
Up (+) and Down (-) buttons
Used to adjust (increasing/decreasing)
temperature settings in 1°C/1°F increments
in a range of 17°C/62°F to 30°C/86°F.
NOTE
The control is capable of displaying
temperature in degrees Fahrenheit or
degrees Celsius. To convert from one
to the other, press and hold the up
and down buttons at the same time
for 3 seconds.
NOTE
On above modes, the unit operates the
auto fan speed automatically. You can
set fan speed only by the remote
control on COOL and FAN modes.
Power button
Power switch on/off.
Power
indicator light
Timer mode indicator
light (set only by
remote control)
LED display
Shows the set te
m
p
e
rature
while on cool mode. While
on DRY and FAN modes, it
shows the room
temperature.
NOTE
When one of the above malfunctions
occurs, turn off the unit and check for
any obstructions. Restart the unit. If the
malfunction persists, turn off the unit
and unplug the power cord. Contact
the manufacturer, its service agents, or
a similarly-qualified person for service.
LED Display
Up (+) and Down (-) Control
Mode
Selector
Power
Button
Shows Error codes:
E1 - Room temperature sensor error.
E2 - Evaporator temperature sensor error.
E3 - Condenser temperature sensor error.
E4 - Display panel communication error.
Shows protection code:
P1 - Bottom tray is full - Connect the drain
hose and drain the collected water away.
If protection code repeats, call for service.
Operating Instructions
Page 7
CONSTANT FAN(Press 3s)
CONSTANT FAN(Press 3s)