NOTE
When one of the above ma
lfunctions
occurs, turn off the unit and check for
any obstructions. Restart the unit. If
the malfunction persists, turn off the
unit and unplug the power cord.
Contact the manufacturer, its service
agents, or a similarly-qualified person
for service.
Operating
Instructions
LED display
Shows the set temperature in °C or °F
and the Auto-timer settings. While on
DRY and FAN modes, it shows the room
temperature.
Shows Error codes and protection code:
E1 - Room temperature sensor error.
E2 - Evaporator temperature sensor error.
E3 - Condenser temperature sensor error
(select models).
E4 - Display panel communication error.
P1 - Bottom tray is full -- Connect the
drain hose and drain the collected
water away. If protection code
repeats, call for service.
Control Panel Features (cont.)