Use And Care Manual

Page 18
7
CARE AND CLEANING
FRONT PANEL AND CASE
Turn unit off and disconnect power supply.
To clean, use water and a mild detergent.
DO NOT use bleach or abrasives. Some
commercial cleaners may damage the
plastic parts.
OUTDOOR COIL
Coil on outdoor side of unit should be
checked regularly. Unit will need to be
removed to inspect dirt build-up that
will occur on the inside of the coil.
If clogged with dirt and soot, coil
should be professionally cleaned of
debris. Clean inside and outside of
outdoor coils regularly.
CAUTION
UNIT DAMAGE HAZARD
Failure to follow these instructions may
result in equipment damage or
improper operation. Airflow restriction
may cause damage to the unit.
CAUTION
UNIT DAMAGE HAZARD
F
ailure to follow these instructions
may result in equipment damage or
improper operation.
Do not operate unit without filters
in place. If a filter becomes torn
or damaged, it should be replaced
immediately.
Operating without filters in place or
with damaged filter will allow dirt
and dust to reach indoor coil and
reduce cooling, heating, airflow and
efficiency of unit. Airflow restriction
may cause damage to unit.
AIR FILTERS
The most important thing you can do to
maintain unit efficiency is to clean the
filters once every two weeks as required.
Clogged filters reduce cooling, heating
and airflow.
Keeping filters clean will:
- Decrease cost of operation.
- Save energy.
- Prevent clogged indoor coil.
- Reduce risk of premature component
failure.
To Clean Air Filters:
- Vacuum off heavy soil.
- Run water through filter.
- Dry thoroughly before replacing.
Care and
Cleaning
NOTE
Never use a high-pressure spray on coil.
IMPORTANT
Turn unit off before cleaning.