Aquagarden products by Pennington have been exclusively designed in partnership with Interpet UK a Leading Britsh water garden company Pennington, 1280 Atalanta Hwy, Madison. GA 30650 www.PenningtonAquagarden.com Leaflet Code: 28/11/11 inpond all-in-one moving water & clarity 300/600 Instrauctions español disponible descargar en: www.PenningtonAquagarden.
CONTENTS Getting to know your Inpond 300 Parts Descriptions / spares codes - with exploded diagram inpond all-in-one moving water & clarity 300/600 Congratulations on buying a Pennington All-in-One. Manufactured with advanced technology to create a clean and healthy pond for your fish.
GETTING TO KNOW YOUR INPOND 300 GETTING TO KNOW YOUR INPOND 300 47 46 45 1 44 43 50 2 44 47 46 45 3 54 29 52 4 44 5 51 43 6 49 53 12 9 39 37 36 35 34 33 38 31 32 50 48 7 8 42 49 21 41 40 10 11 22 13 14 2 15 16 17 18 23 19 24 20 25 26 27 28 30 No. Part Description Spare Code 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. 30. 31. 32. 33. 34. 35. 36. 37.
GETTING TO KNOW YOUR INPOND 300 No. Part Description Spare Code 38. 39. 40. 41. 42. 43. 44. 45. 46. 47. 48. 49. 50. 51. 52. 53. 54. Ball Joint Connector Ball Joint Ball Joint O ring Extension Pipe Connector 30cm Telescopic Extension pipe Control Valve & Diverter Screw on hosetails 1/2" 12.5mm Daisy Super Daisy Water Bell Large New Fountain Adapter Complete Ball Joint Screw on hosetails 1/2" 12.5mm 1/2" 12.5mm Silicon Hose; not included 1/2" 12.
GETTING TO KNOW YOUR INPOND 600 6 GETTING TO KNOW YOUR INPOND 600 No. Part Description Spare Code No. Part Description Spare Code 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. 30. 31. 32. 33. 34. 35. 36. 37.
INSTALLATION GETTING TO KNOW YOUR INPOND Pump performance / flow chart 600 Voltage Watts Safety Rating Maximum Depth Maximum Lift 12v 12w ETL/CE 4’1” 3’2” 12v 28w ETL/CE 4’9” 5’3” Lift 5’ Flow Rates Pump 300 600 Max Flow 203 gal/hr 3’2” 12V IP56 396 gal/hr 5’3” 12V IP56 6’ 15’ 6’ 15’ 12w 28w 0.76w 0.
INSTALLATION INSTALLATION Locating your Inpond All-in-One Convenient Installation The Inpond pump and filter should be located on a firm and level base in the pond/water feature in a depth of at least 4”, but no more than 4’10” for the 300 model and 4’9” for the 600 model. Inpond 300 & 600 FOUNTAIN OPTION Fountain FEATURE OPTION OR Make sure there is ample cable from the transformer. Place product in desired location.
INSTALLATION INSTALLATION Waterfall Installation Inpond 300 INPOND ALL-IN-ONE RUNS A FOUNTAIN OR FEATURE AND LED SPOTLIGHT Important The outlet hose should be smooth bore (not corrugated) pipe installed over as short a distance as possible with no kinks or bends.
MAINTENANCE & CLEANING MAINTENANCE & CLEANING IMPORTANT - Failure to carry out routine maintenance leaving the pump under reduced or no flow conditions for long periods will result in a shorter pump life and will invalidate the guarantee. Opening and locking filter handle Easy lift integrated locking handle The Pennington Inpond All-in-One pump is centrifugal with a magnetic impellor movement driven by a watertight synchronous motor.
UVC Installation Warning - 1) Always turn off the power before any maintenance to the UVC section 2) Always view the UVC lamp through the viewing window on the UVC Chamber 3) Direct exposure to UVC light can damage your eyes and skin. Caution - Inpond UVC has been fitted with a magnetic safety switch. 1) Do not remove unit with power turned on 2) Do not place near strong magnetic fields. UVC Lamps & quartz sleeve maintenance The UVC lamp must be replaced every six months / once a season.
UVC ELECTRICAL INSTALLATION 5 UVC ELECTRICAL INSTALLATION Attention has been drawn to the fact that special rules may exist concerning the installation of your Inpond UVC. This UVC must not be used in swimming pools, or areas where people are in contact with the water. ALIGN ARROWS Danger - Ultra violet Radiation. Do not expose eyes to lamp rays. Disconnect power before servicing or replacing the lamp.
MAINTENANCE & CLEANING MAINTENANCE & CLEANING LED Automatic Photo Sensor Polymer wool cartridge The polymer wool pad may be washed a limited number of times before it starts to lose efficiency and block rapidly. Replacement packs of polymer wool are availible from your retailer and are quick and easy to replace. See page 15 On how to remove the cartridge easiliy from the Inpond.
TROUBLESHOOTING Inpond Filter Cloudy/brown water • The flow rate / pond turnover is to high or to low. Check that you have correctly calculated the pond volume and that pump flow rate is within limits. • The filter is not being supplied with water 24 hours a day. Do not turn off your Inpond. Continuous running is needed to maintain a clean and healthy pond. • The filter foam pads are insufficiently blocked to trap the fine waste.
TROUBLESHOOTING & IMPORTANT UVC light not illuminated • Check all fuses / RCD and electrical connections follow electrical installation Faults - Problem Procedure Before returning your Inpond to your dealer or contacting our Consumer Advice Department, please carry out the following steps. This will solve most problems quickly and easily. 1. Ensure electrical procedures have been followed fully. Check fuses and any cable connectors/switch boxes. 2. (a) Follow routine maintenance procedure fully.