inpond 5-in-1 moving water & clarity 600 Congratulations on buying a Pennington 5-in-1. Manufactured with advanced technology to create a clean and healthy pond for your fish. IMPORTANT Please attach proof of purchase to this manual and file in a safe place. Please visit www.penningtonaquagarden.com for helpful hints, tips, how-to videos and spares HOW TO BUILD YOUR WINDOW POND SEE WEBSITE Instrauctions español disponible descargar en: www.PenningtonAquagarden.
FOR INDOOR AND OUTDOOR USE IMPORTANT SAFETY INSTRUCTIONS WARNING - TO REDUCE THE RISK OF ELECTRIC SHOCK, USE ONLY ON PORTABLE SELF-CONTAINED FOUNTAINS NO LARGER THAN 5 FEET IN ANY DIMENSION. WARNING - RISK OF ELECTRIC SHOCK - THIS PUMP IS SUPPLIED WITH A GROUNDING CONDUCTOR AND GROUNDING TYPE ATTACHMENT PLUG. TO REDUCE THE RISK OF ELECTRIC SHOCK, BE CERTAIN THAT IT IS CONNECTED ONLY TO PROPERLY GROUNDED, GROUNDING-TYPE RECEPTACLE.
S CONTENTS Getting to know your Inpond 600 Parts Descriptions / spares codes - with exploded diagram 2 2,3 & 4 Pump performance / flow chart 5 Specification chart 5 Installation 6 Electrical Installation Installing UVC UVC Electrical Installation Installing Inpond Maintenance and cleaning Cleaning 6 7&8 9 10, 11, 12 & 13 14,15,16 &17 14 Step by Step guides 14 & 15 Routine Maintenance 16 & 17 Annual Maintenance 17 Winter storage 17 Troubleshooting 18,19 & 20 Troubleshooting and maximise
GETTING TO KNOW YOUR INPOND 600 53 54 52 1 51 50 49 2 2nd way of connection 3 53 54 52 50 51 48 4 47 49 5 6 55 7 8 9 12 10 11 13 56 46 45 30 44 43 38 42 41 40 37 31 36 35 34 39 33 32 14 24 15 2 17 16 18 19 25 20 26 27 21 28 22 29 23
GETTING TO KNOW YOUR INPOND 600 No. Part Description Spare Code 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. 30. 31. 32. 33. 34. 35. 36. 37.
GETTING TO KNOW YOUR INPOND 600 4 No. Part Description Spare Code 38. 39. 40. 41. 42. 43. 44. 45. 46. 47. 48. 49. 50. 51. 52. 53. 54. 55. 56. LED Lamp Screw Cap 18.75mm (3/4") Hose Fitting 25mm (1") Hose Fitting 12.
GETTING TO KNOW YOUR INPOND Pump performance / flow chart Tech Specification: 600 Voltage 120V 60hz Watts 24w Safety Rating ETL/CE Maximum Depth 4’9” Maximum Lift 5’3” Lift 5’ Flow Rates 37gal/hr 4’ 106gal/hr 3’ 181gal/hr 2’ 242gal/hr 1’ 0’ Flow is given at optimum rate Pump 600 Max Flow 369 gal/hr 5’3” 16’ 24w Max Head Mains Cable Watts LED Photo sensor activated 0.
INSTALLATION ELECTRICAL SAFETY INFORMATION: Caution: Household indoor and outdoor use. WARNING - Risk of Electric Shock. Mount the unit at a height greater than 1 foot from the ground surface. Install only to covered Class A GFCI receptacle that has an enclosure that is weatherproof with the attachment plug cap inserted or removed. The power supply must meet the specification of the product. Inpond Pump The electric cord is permanently connected and sealed in the motor body.
UVC INSTALLATION Warning - 1) Always turn off the power before any maintenance to the UVC section 2) Always view the UVC lamp through the viewing window on the UVC Chamber 3) Direct exposure to UVC light can damage your eyes and skin. Caution - Inpond UVC has been fitted with a magnetic safety switch. 1) Do not remove unit with power turned on 2) Do not place near strong magnetic fields.
UVC INSTALLATION 1. Unlock the green UVC electronics cap. 2. Inspect the UVC cap and Quartz sleeve for water leaks. 3. Then unlock the yellow quartz sleeve end cap and unplug the lamp to replace if desired 4. If there are no signs of leakage reverse the procedure ensuring that the quartz sleeve O-ring is in place. See alignment diagram. 5. Ensure the yellow quartz sleeve cap and the green UVC electronics cap are firmly sercured by making sure the two looked positions are in direct line of each other.
UVC ELECTRICAL INSTALLATION 5 ALIGN ARROWS Danger - Ultra violet Radiation. Do not expose eyes to lamp rays. Disconnect power before servicing or replacing the lamp. READ THE INSTRUCTIONS Electrical installation - UVC Warning - To rduce the risk of electric shock, connect only to a grounded, grounding-type receptacle.
INSTALLATION Locating your Inpond The Inpond pump and filter should be located on a firm and level base in the pond/water feature in a depth of at least 4”, but no more than 4’10” for the 300 model and 4’9” for the 600 model. Fountain Place product in desired location. Using the telescopic pipe adjust so the fountain head is above the surface of the pond. Fountain height can now be adjusted, see ‘Adjusting flow control’ diagram below.
INSTALLATION Convenient Installation Inpond 600 FOUNTAIN OPTION FEATURE OPTION OR WATER FEATURE FOUNTAIN MIN: 1’3” MAX: 2’3” HOSE INPOND INPOND INPOND, FOUNTAIN AND/OR FEATURE OPTION WATER FEATURE FOUNTAIN INPOND PUMP HOSE 11
INSTALLATION Inpond 600 INPOND 5 in 1 FILTER RUNS A FOUNTAIN, FEATURE AND LED SPOTLIGHT Water Feature 8” extension pipe 12”adjustable tetescopic extension pipe LED Spotlight 20° +/- ball joint adjustment to compensate for uneven pond floor Fully adjustable fountain control. Adjusts fountain height and width. 12 Interchangeable 1”/25mm, 3/ 1 4”/19mm, /2” 12.
INSTALLATION Waterfall Installation Important The outlet hose should be smooth bore (not corrugated) pipe installed over as short a distance as possible with no kinks or bends. Connecting Outlet Hoses Installing the waterfall or feature 600 The recommended hose size for your Inpond Filter is stated in the filter performance and specification chart. On Page 5. Always secure with a Jubilee clip Warming the hose in a bucket of boiling water can aid fitting.
MAINTENANCE & CLEANING IMPORTANT - Failure to carry out routine maintenance leaving the pump under reduced or no flow conditions for long periods will result in a shorter pump life and will invalidate the guarantee. The Pennington Inpond pump is centrifugal with a magnetic impellor movement driven by a watertight synchronous motor. They require minimum cleaning, only periodic cleaning of the impellor is necessary. Routine Maintenance 1. Switch off electricity 2.
MAINTENANCE & CLEANING Opening and locking filter handle Easy lift integrated locking handle 1. Handle in the locked position 2. Handle is in the central position. This will enable the filter and pump to be carried in and out of the pond. *Ensure the filter is not carried by the pump cable. 3. Close handle down to open position 4. The handle is in the unlocked position allowing the filter media to be removed and cleaned. Foams may be cleaned vigorously in a bucket of pond water.
MAINTENANCE & CLEANING Polymer wool cartridge The polymer wool pad may be washed a limited number of times before it starts to lose efficiency and block rapidly. Replacement packs of polymer wool are availible from your retailer and are quick and easy to replace. See page 15 On how to remove the cartridge easiliy from the Inpond.
MAINTENANCE & CLEANING LED Automatic Photo Sensor Automatic LED spot light - detects when light levels are low/dusk The LED automatic sensor is positioned on top of the motor body between the outlet and the lamp. Ensure this is kept clean from dirt and algae as it needs sufficent light to activate correctly. Ball joint LED automatic sensor Pump If the LED light is not required you can permentently remove the lamp.
TROUBLESHOOTING Inpond Filter Cloudy/brown water • The flow rate / pond turnover is to high or to low. Check that you have correctly calculated the pond volume and that pump flow rate is within limits. • The filter is not being supplied with water 24 hours a day. Do not turn off your Inpond. Continuous running is needed to maintain a clean and healthy pond. • The filter foam pads are insufficiently blocked to trap the fine waste.
TROUBLESHOOTING Poor Fountain performance • Reduced height. • Jets blocked. Clean flow adjusters and fountain head. Wash under a tap or hose. Pond Pump Cleaner should be used to remove lime scale build-up/waste (see diagram) for improved results. DAISY To clean, remove head and rinse. Or in hard water areas, use Pond Pump Cleaner No flow from pump 1. Check power supply is on. 2. Check fuse and wiring (SEE ELECTRICAL INSTALLATION). 3. Follow low flow procedure as above.
TROUBLESHOOTING & IMPORTANT UVC light not illuminated • Check all fuses / RCD and electrical connections follow electrical installation Faults - Problem Procedure Before returning your Inpond to your dealer or contacting our Consumer Advice Department, please carry out the following steps. This will solve most problems quickly and easily. 1. Ensure electrical procedures have been followed fully. Check fuses and any cable connectors/switch boxes. 2. (a) Follow routine maintenance procedure fully.
IMPORTANT PUMP & LIGHT This product is guaranteed against defects in material and workmanship for 2 years from date of purchase, under normal usage. This guarantee DOES NOT APPLY in case of improper us, negligence, lack of maintenace or accidental damage either to the pump or the impeller shaft. If the pump fails due to a manufacturing fault within this period it will be either repaired or replaced free of charge.
Aquagarden products by Pennington have been exclusively designed in partnership with Interpet UK a Leading Britsh water garden company Pennington, 1280 Atalanta Hwy, Madison. GA 30650 www.PenningtonAquagarden.