Emergency procedures
:
Contain spill and monitor for excessive dust accumulation. ELIMINATE all ignition sources (no
smoking, flares, sparks or flames in immediate area). Ventilate closed spaces before entering.
Turn off electric power to area. As an immediate precautionary measure, isolate spill or leak
area for at least 100 meters (330 feet) in all directions. Evacuate area.
6.2. Environmental precautions
Avoid release to the environment.
6.3. Methods and material for containment and cleaning up
Methods for cleaning up
:
Sweep or scoop spills, dispose of any unusable material in approved landfill. Use appropriate
PPE. Dust deposits should not be allowed to accumulate on surfaces, as these may form an
explosive mixture if they are released into the atmosphere in sufficient concentration. Non-
sparking tools should be used.
SECTION 7: Handling and storage
7.1. Precautions for safe handling
Precautions for safe handling
:
Ensure good ventilation of the work station. Avoid dust formation. Take all necessary technical
measures to avoid or minimize the release of the product on the workplace. Provide local
exhaust or general room ventilation. Wear personal protective equipment. Avoid breathing
dust/fume/gas/mist/vapours/spray.
Hygiene measures
:
Do not eat, drink or smoke when using this product. Always wash hands after handling the
product.
7.2. Conditions for safe storage, including any incompatibilities
Storage conditions
:
Keep only in original container. Store in a well-ventilated place. Keep cool. Keep away from
heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. Store locked
up.
Incompatible materials
:
Strong oxidizers. Strong acids. Strong bases. Heat, sparks, open flame.
SECTION 8: Exposure controls/personal protection
8.1. Control parameters
Calcium monocarbonate (471-34-1)
NIOSH
NIOSH REL (TWA) (mg/m³)
10 mg/m³ (total dust)
5 mg/m³ (respirable dust)
Silica, crystalline - quartz (14808-60-7)
ACGIH
ACGIH TWA (mg/m³)
0.025 mg/m³ (respirable particulate matter)
OSHA
OSHA PEL (TWA) (mg/m³)
50 µg/m³
IDLH
US IDLH (mg/m³)
50 mg/m³ (respirable dust)
NIOSH
NIOSH REL (TWA) (mg/m³)
0.05 mg/m³ (respirable dust)
8.2. Appropriate engineering controls
Appropriate engineering controls
:
It is recommended that dust control equipment such as local exhaust ventilation and material
transport systems involved in handling of this product contain explosion relief vents or an
explosion suppression system or an oxygen-deficient environment.
Environmental exposure controls
:
Avoid release to the environment.
8.3. Individual protection measures/Personal protective equipment
Hand protection:
Protective gloves
Eye protection:
Safety glasses
Skin and body protection:
If prolonged exposure is anticipated, it is recommended for handlers to wear appropriate clothing to prevent skin contact.
Respiratory protection:
In case of insufficient ventilation, use NIOSH approved respiratory protection.