User's Manual

23
EasyTouch Wireless Control Panel Users and Installation Guide
Using the Egg Timer (count-down) Feature
The “Egg Timer” feature allows you switch off a circuit automatically after a specified time. The time period
can be anywhere from one minute to 24 hours or run continuously. The “Egg Timer” (count-down) feature is
useful for switching off lighting and spa therapy jets. For example, a jet pump can be set to switch off in 15
minutes, even when switched on by the iS4 Spa-Side remote control or whenever you switch your spa on, you
would like it to automatically switch it off in two hours. All Egg Timer programs are factory set to switch off
after 12 hours. You also have the option to use the “Don’t Stop” feature to run a circuit continuously until
manually switched off.
Please note that in the event of a power failure, the “Egg Timer” feature will not switch the circuit back on.
Use the “Service” mode to turn the equipment back on. For running the filter pump continuously during new
pool start up, it is recommended to use the “Service” mode, which will automatically restart the filter pump in
the event of a power failure.
The following example describes how to program the “Egg Timer” for the spa. The same applies when
selecting the pool or any auxiliary circuit.
To set the Egg Timer feature:
Right button: Select the Spa circuit.
Right button: Select Mode if there are existing programs. Skip this step to create a
new program.
Up/Down button: Select New to create a new program.
Right button: To create a new program and enter the “Mode” settings.
Up/Down button: 1/1 indicates that this circuit has one program. If there are existing
programs assigned to this circuit, use these buttons to view and select the existing
program settings.
Right button: To select the “Egg Timer” settings.
Right button: Move to the time settings.
Up/Down and Right buttons: Set the hour and minutes for the program to run. The
count down time can be set from 00:01 to 23:59 and Don’t Stop. The “Don’t Stop”
feature allows the circuit to run continuously until manually switched off.
Menu/Select: Press this button to save settings and to return to the Schedules menu
options. Press the button again to return to the main menu options or press again to
return to the Main screen.
Spa 1/1
Mode: Egg Timer
Time: 05:00
T
S
Getting There
SCHEDULES SPA
Spa 0/0
Mode: None (New)
S
Spa 0
Pool 0
Aux 1 0
Aux 2 0
T
S
X