Diagnostics Menu: Chlorinator
Displays the current IntelliChlor chlorination system status. For more information, refer to the IntelliChlor
Electronic Chlorine Generator Users Guide (P/N 520589).
Menu/Select: Press this button to return to the Settings menu options. Press the
button again to return to the main menu options or press again to return to the Main
screen.
SALT LEVEL: Displays the current salt level. Values from 0 to 12750 ppm in 50 ppm
increments.
IntelliChlor Status messages:
SUPER CHLORINATE: IntelliChlor is in “Super Chlorination mode (see page 25)
COM LINK ERROR: Check cable from IntelliChlor to EasyTouch motherboard.
Check FLOW/PCB: Check IntelliChlor electrolytic cell controller. Refer to IntelliChlor
Users Guide troubleshooting information.
LOW SALT: Add salt to pool water. The water salt level is between 2500 ppm and
2900 ppm. The IntelliChlor will continue to produce chlorine at a reduced level.
VERY LOW SALT: Not enough salt in pool. The water salt level has fallen below 2500
parts per million (ppm). IntelliChlor will not produce chlorine until additional salt is
added manually.
HIGH CURRENT: Check IntelliChlor electrolytic cell controller. Refer to IntelliChlor
Users Guide troubleshooting information..
CLEAN CELL!!: Cell has calcium build up and requires cleaning. Refer to IntelliChlor
Users Guide for cleaning instructions.
LOW VOLTAGE: Check IntelliChlor electrolytic cell controller. Refer to IntelliChlor
Users Guide troubleshooting information.
OK - NO ERRORS: IntelliChlor is in normal operating mode.
Diagnostics Menu: Water Temp
Displays the current water temperature for the pool and spa.
Menu/Select: Press this button to return to the Settings menu options. Press the
button again to return to the main menu options or press again to return to the Main
screen.
Diagnostics Menu: Solar Temp
Displays the current temperature.
Menu/Select: Press this button to return to the Settings menu options. Press the
button again to return to the main menu options or press again to return to the Main
screen.
DIAGNOSTICS WATER TEMP
Getting There
DIAGNOSTICS SOLAR TEMP
Getting There
DIAGNOSTICS CHLORINATOR
Getting There
T
Chlorinator
Salt Level:3200ppm
Status:
[OK-NO ERRORS]