User's Manual

6
IntelliCenter Control System Wireless Control Panel Installation Guide
IntellliCenter Control System Wireless Control Panel Installation Guide
Connecting the Transceiver to the IntelliCenterâ„¢ Control System Load Center
SWITCH OFF AC POWER TO THE INTELLICENTER CONTROL SYSTEM LOAD
CENTER BEFORE MAKING ANY CONNECTIONS.
IntelliCenterâ„¢ Load Center Control System Load Center (front view)
(High Voltage Cover Panel removed)
To connect the Transceiver wires to the COM port on the system circuit board:
BEFORE REMOVING THE HIGH VOLTAGE COVER PANEL FROM THE
LOAD CENTER OR POWER CENTER ENCLOSURE SWITCH OFF THE POWER
AT THE HOUSE MAIN CIRCUIT BREAKER BOX.
1. Switch OFF AC power to the enclosure at the main house panel circuit breaker.
2. Unlatch the front door latch and open the front door. Remove the two retaining screws from the High
Voltage Cover Panel and remove the panel.
3. Loosen the two retaining screws securing from the top edge of the Outdoor Control Panel. Fold
down the Outdoor Control Panel to access the circuit board sockets connectors for the electrical
connections. Remove the panel from the enclosure (see illustration below).
4. Route the four conductor transceiver connection cable into the lower plastic grommet, up through
the low voltage raceway to the system circuit board.
LOW VOLTAGE
RACEWAY
High Voltage Cover Panel Tabs (3)
Remove two (2) retaining
screws securing High Voltage
Cover Panel
Front door
High Voltage Cover Panel slots (3)
Flip down the Outdoor Control Panel
to access circuit board and low
voltage compartment
Loosen Outdoor Control