INTELLIFLO
®
Variable Speed Pump Installation and User’s GuideINTELLIFLO
®
Variable Speed Pump Installation and User’s Guide
Set Maximum Speed (RPM)
The maximum speed can be set from 1900 RPM to
3450 RPM (default is 3450). Use this setting is to set
the maximum running speed of the IntelliFlo
®
Variable
Speed Pump.
When the pump is set to Priming “Enabled”, the pump
will speed up to and run at this speed to prime. A service
professional must set the Maximum Speed of the pump
to not exceed the maximum flow rate of the system on
which it will operate.
1. Check that the green power LED is on.
2. Press Menu.
3. Press Select to select “Settings”.
4. Use the Up or Down arrows to scroll to “Set Max
Speed”.
5. Press Select to change. The cursor will appear in
the first number column (ones).
6. Press Up or Down arrows to change the maximum
speed setting from 1900 to 3450 RPM.
7. Press Enter. Press Escape to exit. To cancel, press
the Escape to exit without saving.
The Maximum Flow rate setting should be set so the
system never operates at or above 25” of Hg vacuum.
4. Use the Up or Down arrows to scroll to “Set Min
Speed”.
5. Press Select to change the setting. The cursor will
appear in the first number column.
6. Press the Up or Down arrows to change the minimum
speed setting from 450 to 1700 RPM.
7. Press Enter to save. To cancel, press Escape to
exit edit mode without saving.
8. Press Escape to exit.
MENU
SETTINGS
(1-16) Default: ADDRESS 1
(hr:mm) Default: 12:00 AM
Set AM/PM
AM/PM
24 hr.
Fahrenheit - Default: F°
C° Celsius
(1-5) Default 3
(450 RPM - 1700 RPM) - Default: 450 RPM
(1900 RPM - 3450 RPM) - Default: 3450 RPM
Pump Address
Set Time
Temperature Unit
Screen Contrast
Language
Set Min Speed
Set Max Speed
PASSWORD
Password Time Out (1 min. - 6 hours) Default:10 minutes
Disabled/Enabled - Default: Disabled
Enter Password (xxxx) Default: 1234
English - Default: English
Set Minimum Speed (RPM)
The minimum pump speed can be set from 450 RPM
to 1700 RPM. The default setting is 450 RPM.
1. Check that the green power LED is on.
2. Press Menu.
3. Press Select to select “Settings”.
Password Protection
The default setting for password protection is disabled.
When this feature is enabled, the pump display will
prompt for the password before allowing access to the
control panel and buttons.
The entered password is any combination of four (4)
digits.
• Password protection can always be turned off by
pressing Start/Stop.
• Password protection cannot be turned back on with
Start/Stop while running in manual mode.
• Pressing Start/Stop when the pump is off will return
it back to the Running Cycles Mode and run at
the next scheduled run time. If the present time is
within the scheduled run time, the pump will run the
scheduled speed.
• All functions including programming are disabled in
Password Protection Mode.
• Screen will read “Enter Password” if any button other
than the Start/Stop button is pressed.
• Key icon displayed in the upper left side of the
screen when Password Protection is on.
Password
Protection
Enabled
12:15p
750 RPM
Actual Speed
Running Speed 1
Language
To access the language menu:
1. Check that the green power LED is on.
2. Press the Menu button. “Settings” is displayed.
3. Press the Select button. “Pump Address” is displayed.
4. Use the Up or Down arrow button to scroll to
“Language”.
5. Press the Select button to access the language menu.
6. Press Select to highlight current Language in use.
7. Press the Enter button to select the desired language
for the control panel. To cancel any changes, press
the Escape button to exit edit mode without saving.
8. Press the Escape button to exit.
Pump Menu: Settings