Instructions / Assembly

ENGLISH
EVERPURE H-Series Water Filtration Systems 11
H1200 CARTRIDGE  PART NO. EV928201, EV928203,
IMPORTANT NOTICE: Read this Performance Data Sheet and
compare the capabilities of this unit with your actual water
treatment needs. It is recommended that, before purchasing a
water treatment unit, you have your water tested to determine
your actual treatment needs.
FEATURES
Finely polishes treated water to premium quality for
drinking and cooking.
NSF/ANSI Standard 53 certified to reduce cysts such as
Cryptosporidium and Giardia by mechanical means.
IAPMO R&T certified against NSF/ANSI 53 for the reduction
of perfluorooctanoic acid (PFOA) and perfluorooctane
sulfonate (PFOS).
High-performance system certified to reduce up to 97.5% of
PFOA/PFOS, commonly known as "forever chemicals".
Reduces dirt, rust and other particulates sulfides (oxidized iron
and manganese As tested by Everpure).
Controls even extreme levels of common "off" taste and odors,
including those which are earthy, moldy, and fishy.
Reduces lead to below the Federal Action Level of 15 ppb.
Effectively reduces Volatile Organic Chemicals (VOCs),
including Trihalomethanes (THMs).
Effectively reduces methyl tertiary-butyl ether (MTBE).
Reduces particles as small as 0.5 micron in size by
mechanical means.
H-1200 Performance Data
This system has been tested according to NSF/ANSI 42 and 53
for the reduction of the substances listed below.
The concentration of the indicated substances in water entering
the system was reduced to a concentration less than or equal to
the permissible limit for water leaving the system, as specified
in NSF/ANSI 42 and 53.
PERFORMANCE DATA SHEET
H1200 DRINKING WATER SYSTEMS
OPERATING SPECIFICATIONS
• Capacity: 1,000 gallons (3,785L)
• Pressure Requirement: 10-125 psi (0.7 - 8.6 bar), non-shock
• Temperature: 35-100°F (2°-38°C)
• Flow Rate: 0.5 gpm (1.9 Lpm
PERFORMANCE DATA SHEET REDUCTION CLAIMS FOR
ORGANIC CHEMICALS INCLUDED BY SURROGATE TESTING
NOTE: Spent adsorption media will not be regenerated and used.
If adsorption media is affected by chlorine, water supply should be
treated to remove chlorine prior to entering filter.
ENGLISH
EVERPURE H-Series Water Filtration Systems 11
IMPORTANT NOTICE: Read this Performance Data Sheet and
compare the capabilities of this unit with your actual water
treatment needs. It is recommended that, before purchasing a water
treatment unit, you have your water tested to determine your actual
treatment needs.
FEATURES
dna gniknird rof ytilauq muimerp ot retaw detaert sehsilop yleniF
cooking.
NSF/ANSI Standard 53 certied to reduce c ysts such as
Cryptosporidium and Giardia by mechanical means.
dna nori dezidixo( sediflus setalucitrap rehto dna tsur ,trid secudeR
manganese - As tested by Everpure).
slortnoC even extreme levels of common “o” tastes and odors,
including those which are earthy, moldy, and shy.
Reduces lead to be low the Federal Action L evel of 15 ppb.
( slacimehc cinagro elitalov secuder ylevitceffE VOCs), including
trihalomethanes (THMs).
Eectively reduces methyl tertiary-butyl ether (MTBE).
Reduces particles as small as 0.5 micron in size by mechanical
means.
ERFORMANCE DATA
This system has been tested according to NSF/ANSI 42 and 53 for
the reduction of the substances listed below. The concentration of
the indicated substances in water entering the sy stem was
reduced to a concentration less than or equal to the permissible
limit for water leaving the sy stem, as specied in NSF/ANSI 42
and 53.
Substance
Influent Challenge
Concentration
Max. Permissible Product
Water Concentration
Reduction
Requirements
Minimum
Reduction
Average
Reduction
Standard 42—Aesthetic Eects
Chlorine 2.0 mg/L ± 10% ≥ 50% 86.8%
Chloramine 3.0 mg/L ± 10% 0.5 mg/L 98.3%
Particulate,
Class I
particles 0.5
to <1 µm
at least 10,000
particles/mL
≥ 85% 98.8%
Standard 53—Health Eects
Cyst Minimum 50,000/L 99.95% 99.99% 99.99%
Lead 6.5 0.15 mg/L ± 10% 0.005 mg/L 99.3% 99.3%
Lead 8.5 0.15 mg/L ± 10% 0.005 mg/L 98.7% 99.3%
Methyl tert-
butyl ether
0.015 mg/L ± 20% 0.005 mg/L 83.5% 91.5%
Chloroform 0.300 mg/L 0.015 mg/L 99.8% 99.8%
*Tested using flow rate = 0.5 gpm; pressure = 60 psig; pH = 7.5 ± 0.5; temp. = 20° ± 2.5°C
EPA Est. 002623-IL-002
OPERATING SPECIFICATIONS
Capacity: 1,000 gallons (3,780L)
Pressure requirement: 10-125 psi (0.7 - 8.6 bar), non-shock
Temperature: 35-100°F (2-38°C)
Flow Rate: 0.5 gpm (1.9 Lpm)
Performance Data Sheet Reduction Claims
for Organic Chemicals Included by Surrogate Testing
Substance
Inuent Challenge
Concentration mg/L
Maximum Permissible Product
Water Concentration mg/L
alachlor 0.050 0.001
atrazine 0.100 0.003
benzene 0.081 0.001
carbofuran 0.190 0.001
carbon tetrachloride 0.078 0.0018
chlorobenzene 0.077 0.001
chloropicrin 0.015 0.0002
2,4-D 0.110 0.0017
dibromochloropropane (DBCP) 0.052 0.00002
o-dichlorobenzene 0.080 0.001
p-dichlorobenzene 0.040 0.001
1,2-dichloroethane 0.088 0.0048
1,1-dichloroethylene 0.083 0.001
cis-1,2-dichloroethylene 0.170 0.0005
trans-1,2-dichloroethylene 0.086 0.001
1,2-dichloropropane 0.080 0.001
cis-1,3-dichloropropylene 0.079 0.001
dinoseb 0.170 0.0002
endrin 0.053 0.00059
ethylbenzene 0.088 0.001
ethylene dibromide (EDB) 0.044 0.00002
haloacetonitriles (HAN):
bromochloroacentonitrile
dibromoacetonitrile
dichloroacetonitrile
trichloroacetonitrile
0.022
0.024
0.0096
0.015
0.0005
0.0006
0.0002
0.0003
haloketones (HK):
1,1-dichloro-2-propanone
1,1,1-trichloro-2-propanone
0.0072
0.0082
0.0001
0.0003
heptachlor 0.080 0.0004
heptachlor epoxide 0.0107 0.0002
hexachlorobutadiene 0.044 0.001
hexachlorocyclopentadiene 0.060 0.000002
lindane 0.055 0.00001
methoxychlor 0.050 0.0001
pentachlorophenol 0.096 0.001
simazine 0.120 0.004
styrene 0.150 0.0005
1,1,2,2-tetrachloroethane 0.081 0.001
tetrachloroethylene 0.081 0.001
toluene 0.078 0.001
2,4,5-TP(silvex) 0.270 0.0016
tribromoacetic acid 0.042 0.001
1,2,4-trichlor
obenzene 0.160 0.0005
1,1,1-trichloroethane 0.084 0.0046
1,1,2-trichloroethane 0.150 0.0005
trichloroethylene 0.180 0.001
trihalomethanes (includes):
chlor oform (surrogate
chemical)
bromoform
bromodichloromethane
chlorodibromomethane
0.300 0.015
xylenes (total) 0.070 0.001
H-1200 Cartridge - Part Nos. EV9282-01, EV9282-03
H-1200 DRINKING WATER SYSTEM
The H-1200 is Tested and Certied by NSF
International against CSA B483.1 and NSF/ANSI 42
and 53 for the claims specified on the Performance
Data Sheet.
C US
PER FORM ANCE DATA SHEE T
NOTE:
Spent adsorption media will not be regenerated and used.
If adsorption media is aected by chlorine, water supply should be
treated to remove chlorine prior to entering lter.
PFOA/PFOS
0.0015 mg/L ± 10% 0.00007 mg/L 95.76% 97.57%
EVERPURE
EVERPURE
ENGLISH
EVERPURE H-Series Water Filtration Systems 11
IMPORTANT NOTICE: Read this Performance Data Sheet and
compare the capabilities of this unit with your actual water
treatment needs. It is recommended that, before purchasing a water
treatment unit, you have your water tested to determine your actual
treatment needs.
FEATURES
dna gniknird rof ytilauq muimerp ot retaw detaert sehsilop yleniF
cooking.
NSF/ANSI Standard 53 certied to reduce c ysts such as
Cryptosporidium and Giardia by mechanical means.
dna nori dezidixo( sediflus setalucitrap rehto dna tsur ,trid secudeR
manganese - As tested by Everpure).
slortnoC even extreme levels of common “o” tastes and odors,
including those which are earthy, moldy, and shy.
Reduces lead to be low the Federal Action L evel of 15 ppb.
( slacimehc cinagro elitalov secuder ylevi
tceffE VOCs), including
trihalomethanes (THMs).
Eectively reduces methyl tertiary-butyl ether (MTBE).
Reduces particles as small as 0.5 micron in size by mechanical
means.
ERFORMANCE DATA
This system has been tested according to NSF/ANSI 42 and 53 for
the reduction of the substances listed below. The concentration of
the indicated substances in water entering the sy stem was
reduced to a concentration less than or equal to the permissible
limit for water leaving the sy stem, as specied in NSF/ANSI 42
and 53.
Substance
Influent Challenge
Concentration
Max. Permissible Product
Water Concentration
Reduction
Requirements
Minimum
Reduction
Average
Reduction
Standard 42—Aesthetic Eects
Chlorine 2.0 mg/L ± 10% ≥ 50% 86.8%
Chloramine 3.0 mg/L ± 10% 0.5 mg/L 98.3%
Particulate,
Class I
particles 0.5
to <1 µm
at least 10,000
particles/mL
≥ 85% 98.8%
Standard 53—Health Eects
Cyst Minimum 50,000/L 99.95% 99.99% 99.99%
Lead 6.5 0.15 mg/L ± 10% 0.005 mg/L 99.3% 99.3%
Lead 8.5 0.15 mg/L ± 10% 0.005 mg/L 98.7% 99.3%
Methyl tert-
butyl ether
0.015 mg/L ± 20% 0.005 mg/L 83.5% 91.5%
Chloroform 0.300 mg/L 0.015 mg/L 99.8% 99.8%
*Tested using flow rate = 0.5 gpm; pressure = 60 psig; pH = 7.5 ± 0.5; temp. = 20° ± 2.5°C
EPA Est. 002623-IL-002
OPERATING SPECIFICATIONS
Capacity: 1,000 gallons (3,780L)
Pressure requirement: 10-125 psi (0.7 - 8.6 bar), non-shock
Temperature: 35-100°F (2-38°C)
Flow Rate: 0.5 gpm (1.9 Lpm)
Performance Data Sheet Reduction Claims
for Organic Chemicals Included by Surrogate Testing
Substance
Inuent Challenge
Concentration mg/L
Maximum Permissible Product
Water Concentration mg/L
alachlor 0.050 0.001
atrazine 0.100 0.003
benzene 0.081 0.001
carbofuran 0.190 0.001
carbon tetrachloride 0.078 0.0018
chlorobenzene 0.077 0.001
chloropicrin 0.015 0.0002
2,4-D 0.110 0.0017
dibromochloropropane (DBCP) 0.052 0.00002
o-dichlorobenzene 0.080 0.001
p-dichlorobenzene 0.040 0.001
1,2-dichloroethane 0.088 0.0048
1,1-dichloroethylene 0.083 0.001
cis-1,2-dichloroethylene 0.170 0.0005
trans-1,2-dichloroethylene 0.086 0.001
1,2-dichloropropane 0.080 0.001
cis-1,3-dichloropropylene 0.079 0.001
dinoseb 0.170 0.0002
endrin 0.053 0.00059
ethylbenzene 0.088 0.001
ethylene dibromide (EDB) 0.044 0.00002
haloacetonitriles (HAN):
bromochloroacentonitrile
dibromoacetonitrile
dichloroacetonitrile
trichloroacetonitrile
0.022
0.024
0.0096
0.015
0.0005
0.0006
0.0002
0.0003
haloketones (HK):
1,1-dichloro-2-propanone
1,1,1-trichloro-2-propanone
0.0072
0.0082
0.0001
0.0003
heptachlor 0.080 0.0004
heptachlor epoxide 0.0107 0.0002
hexachlorobutadiene 0.044 0.001
hexachlorocyclopentadiene 0.060 0.000002
lindane 0.055 0.00001
methoxychlor 0.050 0.0001
pentachlorophenol 0.096 0.001
simazine 0.120 0.004
styrene 0.150 0.0005
1,1,2,2-tetrachloroethane 0.081 0.001
tetrachloroethylene 0.081 0.001
toluene 0.078 0.001
2,4,5-TP(silvex) 0.270 0.0016
tribromoacetic acid 0.042 0.001
1,2,4-trichlor
obenzene 0.160 0.0005
1,1,1-trichloroethane 0.084 0.0046
1,1,2-trichloroethane 0.150 0.0005
trichloroethylene 0.180 0.001
trihalomethanes (includes):
chlor oform (surrogate
chemical)
bromoform
bromodichloromethane
chlorodibromomethane
0.300 0.015
xylenes (total) 0.070 0.001
H-1200 Cartridge - Part Nos. EV9282-01, EV9282-03
H-1200 DRINKING WATER SYSTEM
The H-1200 is Tested and Certied by NSF
International against CSA B483.1 and NSF/ANSI 42
and 53 for the claims specified on the Performance
Data Sheet.
C US
PER FORM ANCE DATA SHEE T
NOTE:
Spent adsorption media will not be regenerated and used.
If adsorption media is aected by chlorine, water supply should be
treated to remove chlorine prior to entering lter.
PFOA/PFOS
0.0015 mg/L ± 10% 0.00007 mg/L 95.76% 97.57%
EVERPURE
EVERPURE H-Series Water Filtration Systems 11
H-104 Cartridge - Part No. EV9612-11, EV9612-16
IMPORTANT NOTICE: Read this Performance Data Sheet and
compare the capabilities of this unit with your actual water
treatment needs. It is recommended that, before purchasing a water
treatment unit, you have your water tested to determine your actual
treatment needs.
FEATURES
dna gniknird rof yt i lauq muimerp ot retaw detaert sehsi lop yleniF
cooking.
Reduces chlorine taste and odor.
, nor i dez i d i xo sa hcus se t a l uc i t rap reht o dna t sur , t r i d secudeR
manganese, and sulfides.
NSF/ANSI Standard 53 certified to reduce cysts such as
Cryptosporidium and Giardia by mechanical means.
Reduces common earthy, moldy, fishy tastes and odors.
Reduces lead to below the Federal Action Level.
Reduces particles as small as 0.5 micron in size by mechanical
means.
H-104 PERFORMANCE DATA
This system has been tested according to NSF/ANSI 42 and 53 for
the reduction of the substances listed below. The concentration of
the indicated substances in water entering the system was reduced
to a concentration less than or equal to the permissible limit for
water leaving the system, as specified in NSF/ANSI 42 and 53.
Substance
Influent Challenge
Concentration
Max. Permissible Product
Water Concentration
Reduction
Requirements
Minimum
Reduction
Average
Reduction
Standard 42—Aesthetic Effects
Chlorine 2.0 mg/L ± 10% ° 50% 87.8%
Particulate,
Class I
particles 0.5
to <1 µm
at least 10,000
particles/mL
° 85% 98.8%
Standard 53—Health Effects
Cyst Minimum 50,000/L 99.95%
99.99% 99.99%
Lead 8.5 0.15 mg/L ± 10% 0.010 mg/L 99.3% 99.3%
Lead 6.5 0.15 mg/L ± 10% 0.010 mg/L 98.7% 99.3%
*Tested using flow rate = 0.5 gpm; pressure = 60 psig; pH = 7.5 ± 0.5; temp. = 20° ± 2.5°C
OPERATING SPECIFICATIONS
Capacity: 1,000 gallons (3,780L)
Pressure requirement: 10-125 psi (0.7 - 8.6 bar), non-shock
Temperature: 35-100°F (2°-38°C)
Flow Rate: 0.5 gpm (1.9 Lpm)
EPA Est. 002623-IL-002
GENERAL INSTALLATION/OPERATION/MAINTENANCE
REQUIREMENTS
gnidulcni )mc 15 x 31 x 31( .ni 02 x 5 x 5 :deriuqer ecapS
inches of clear space under unit for cartridge change.
Install vertically with cartridge hanging down.
Use minimum length of tubing possible.
Flush new cartridge at full flow for three minutes to purge air.
semoceb wo l f nehw r o , dehcae r s i y t i capac nehw segd i r t r ac eca l peR
too slow, but at least annually.
SPECIAL NOTICES
Installation instructions, parts and service availability, and standard
warranty are included with the product.
This drinking water system must be maintained according to
manufacturer’s instructions, including replacement of filter
cartridges. Suggested retail $122.99.
Do not use with water that is microbiologically unsafe or of unknown
quality without adequate disinfection before or after the system.
Systems certified for cyst reduction may be used on disinfected
waters that may contain filterable cysts.
The contaminants or other substances removed or reduced by this
water treatment system are not necessarily in your water.
Check for compliance with state and local laws and regulations.
Tested under standard laboratory conditions, actual performance
may vary.
Spent adsorption media will not be regenerated and used.
If adsorption media is affected by chlorine, water supply should be
treated to remove chlorine prior to entering filter.
System Tested and Certified by NSF International against
CSA B483.1 and NSF/ANSI 42 and 53 for the claims
specified on the Performance Data Sheet.
H-104 DRINKING WATER SYSTEMS
C US
PERFORMANCE DATA SHEET
The H-1200 is Tested and Certified by NSF
International against CSA B483.1 and NSF/ANSI 42
and 53 for the claims specified on the Performance
Data Sheet.
EPA Est. No. 002623-IL-002
The H-1200 is certied by IAPMO R&T against
NSF/ANSI 53 for the reduction of peruorooctanoic
acid (PFOA) and peruorooctane sulfonate (PFOS).