Instructions / Assembly

ENGLISH
6EVERPURE H-Series Water Filtration Systems
1
1
2
3
5
6
7
8
9
10
11
12
4
Q
R
S
T
Label
Lug
U
X
6
V W
Y
6. INSTALL AND FLUSH FILTER CARTRIDGE
Q. Lift handle of the built-in shut off Valve on the Head.
R. Hold Head rmly with one hand.
S. Align cartridge lug with label on lter Head.
T. Insert lter Cartridge – Push upwards.
U. Turn it to the right – About 1⁄4 turn – Until rotation
stops.
V. Open Side Valve of Angle Stop Adaptor and check for
leaks up to Inlet Elbow Fitting.
W. Open Filtered Water Faucet.
X. Lower handle of built-in shut off valve on the Head,
to ush water to the sink.
NOTE:
Flush new lter cartridges for at least 5
minutes to remove air and any loose carbon. At rst
the water may appear cloudy due to trapped air in
the lter and tubing. If water continues to be cloudy
for more than one week, please contact Everpure
Technical Services for assistance.
Y. Activate Filter Timer by pinching bubble until you
feel a change in resistance as the lter timer “pops.”
Within a few seconds, a thin RED line will appear in
the white window showing the Timestrip has been
activated. Peel away backing and adhere to desired
location. When the white window is completely lled
with RED, it is time to replace your product.
H-1200 INSTRUCTIONS
Tools Needed For Installation
#2 Phillips Screwdriver
Wrench
Utility Knife
Measuring Tape
Pencil
1. OPEN CARTON & INSPECT PARTS
Installation Parts
Key Description Part No.
1 Twin Filter Head N/A
2
H-1200 Filter Cartridges
(Set of 2) (
Includes
10
)
EV928201
3 Locking Washers (2 req.) EV306204
4 Screws (2 req.) EV306196
5 Angle Stop Valve Adaptor EV312120
6 Tubing, 1/4" poly (per foot) A0860119
7
Elbow Fitting Pack Restrictor
(incl. Qty. 2 ea of #3 & #4)
EV308168
8 Plumbers Tape EV312119
9 Faucet Connector EV312135
10 Everpure Filter Timer EV314160
11
Shut Off Valve,
3/8" John Guest x 3/8" FPT
EV309860
12 Coupler, 3/8" FPT Stainless EV312350