PENTAIR INVERTEMP® DB R32 IVTP-1M-DB IVTP-2M-DB IVTP-3M-DB IVTP-4M-DB IVTP-5M-DB IVTP-6M-DB INSTALLATION AND OPERATING MANUAL IMPORTANT SAFETY INSTRUCTIONS, PLEASE READ AND FOLLOW ALL THE INSTRUCTIONS, KEEP THESE INSTRUCTIONS EN PENTAIR AQUATIC SYSTEMS (Rev. 12/2020) i = Download the manual available in EN / FR / NL / DE / IT / ES on www.pentairpooleurope.
EN - SWIMMING POOL INVERTEMP-DB HEAT PUMP Pentair thanks you for your trust and for purchasing the Pentair InverTemp®-DB, the full inverter swimming pool heat pump. In this manual, the heat pump is referred to as HP. To fully enjoy all the features of your InverTemp HP, please read this operating manual carefully. Store it carefully so that it can be consulted at any time.
WARNING AND IMPORTANT SAFETY INSTRUCTIONS This symbol indicates that the device uses R32, a coolant featuring a low combustion speed. This symbol indicates that a maintenance technician must handle this equipment according to the operating manual. This symbol indicates that the operating manual should be read attentively prior to use. WARNING: In normal conditions, a suitable HP can heat the water of the pool by 1°C to 2°C per day.
TABLEAU TABLE OFDES CHARACTERISTICS CARACTÉRISTIQUES Model IVTP-1M-DB Conditions Heating capacity (boost Mode) Continuous power (COP) (boost Mode) Heating capacity (Smart mode) Continuous power (COP) (Smart mode) Heating capacity (Eco mode) Continuous power (COP) (Eco mode) Conditions Heating capacity (boost Mode) Continuous power (COP) (boost Mode) Heating capacity (Smart mode) Continuous power (COP) (Smart mode) Heating capacity (Eco mode) Continuous power (COP) (Eco mode) Conditions Heating capacity
LIVRAISON DELIVERY TRANSPORT TRANSPORT When you have unpacked the HP, please check the content to report any damage. Please also check that the pressure reading on the pressure gauge is equal to the pressure mentioned on the box, depending on the measured outdoor temperature, as different values might indicate a leak. The HP should always be stored and transported in a vertical position, on a pallet and inside its original packaging. Transporting and/or storing the HP horizontally will void the guarantee.
INSTALLATION (SITE, TYPE OF SUPPORT, NECESSARY SPACE) – Install the HP outdoors at more than 2 metres from the pool, as per applicable laws (NF C 15 100). – Place the HP on the provided vibration absorbers on a surface that is stable, solid (able to bear the weight of the device) and level (prepare a concrete base if necessary).
DIMENSIONS: C G INVERTEMP F A B E D A B C D E F G IVTP-1M-DB IVTP-3M-DB IVTP-2M-DB IVTP-4M-DB 665mm 977 mm 431 mm 510 mm 410 mm 103 mm 290 mm IVTP-5M-DB IVTP-6M-DB 759 mm 1076 mm 494 mm 669 mm 465 mm 92 mm 320 mm Models HYDRAULIC CONNECTIONS: – Water quality necessary for this device: NF-EN-16713-3 – The HP is compatible with all types of water treatment.
ELECTRICAL CONNECTIONS: Connection of the power supply: – Prior to undertaking any intervention inside the HP, it is imperative to disconnect the power supply from the HP: there is a risk of electrocution that can cause damages, severe injuries, and even death. – Only a certified and experienced technician is authorised to conduct cabling work in an HP or to replace the power cable. – The power supply should match the voltage featuring on the information plate of the HP.
ELECTRICAL CONNECTIONS : Terminal connections: Single-phase version: P1 P2 L N P1 P2 L N P1 P2 L1 L2 L3 N GND P1 P2 L1 L2 L3 N 230 V 10A 380 V 3 Earthing Neutral Indicative colour 230 V Phase 230 V 10A GND Relay outlet Inlet - general power supply of the filtration pump 230 V ~ 50Hz Remote control: IN BUS YEL IN BUS GRN BUS GND GND Dry contact input (remote ON-OFF) Black Indicative colour Green RS-485 Yellow ON / OFF Connection bus (Modbus card option) Pe
ELECTRICAL CONNECTIONS: Heating priority: The filtration pump can be connected to the HP to force the filtration to operate if the water is not at the desired temperature. Prior to this connection, a “dry contact” (normally open relay or connector) with a 230V AC coil should be provided. Electrical connections: – Connect the coil of this relay (A1 and A2) on the P1 and P2 terminals of the HP.
WiFi CONNECTION ≠1: Application download In the Apple or Android store, download the app Smart Life - Smart Living ≠2: Create an account and log in Follow the account creation instructions ≠3: Add the heat pump ≠3.1: Click “Add” ≠4: Input the Wi-Fi ≠4.1: Press “Enter” ≠3.2: Select “Large device” ≠3.3: Select “Smart Heat Pump (BLE + WiFi)” ≠4.3: Select the desired network, enter the password then confirm ≠4.2: Press “Next” 10:43 10:43 Reset the Wi-Fi Esc Enter OK ≠5: Use the app ≠5.
SETTINGS: Water flow setting: – To optimise the heating performance and achieve power savings, the flow of water travelling through the HP should be adjusted. – The adjustment is done based on the reading of the adjustment pressure gauge. The adjustment is done by opening or closing the adjustment valve of the bypass. – To increase the pressure on the front pressure gauge: reduce the amount of water passing through the HP: open the bypass adjustment valve.
REGULATION (ELECTRONIC CONTROL UNIT) Rotating fan Selected mode Water flow detected P1-P2 relays for activated swimming pool pump Compressor operating 10:43 10:43 11 27 12 : 28 13 29 12h 24h am/pm am Date 2020 09 17 2021 10 18 2022 11 19 Year Month Day OK OK Time 10:43 10:43 Selected energy mode Timer 2 OFF Setting of the timers (accessible by contacting technical support) Cooling mode Wi-Fi connected OK Automatic mode Home screen (2 sec) Current temperature of the wate
TABLE OF THE DIFFERENT STATES OF THE DISPLAY Display St-by FLO AL10 / AL11 Meaning Standby No/insufficient water flow HP error AL15 / AL16 Excessive temperature difference between water outlet/inlet AL18 Excessive temperature at the compressor outlet AL17 Protection temperature too low in cooling SAL7 / AL8 Communication error.
MAINTENANCE – Prior to undertaking any maintenance operation on the HP, it is imperative to disconnect the power supply from the HP: there is a risk of electrocution that can cause damages, severe injuries, and even death. Maintenance operations are to be conducted by a qualified technician. Cleaning (must be conducted by a qualified technician at least once yearly): – The cleaning of the inlet of the evaporators and of the outlet of the fan are necessary to maintain a sufficient yield.
CIRCUIT DIAGRAMS IVTP-1M-DB IVTP-2M-DB Reactor COMPRESSOR CM IVTP-4M-DB IVTP-3M-DB FAN MOTOR Towards the pump (≤1kW) 220~240V 2N ~50Hz Dry contact ON/OFF J/V MF U V W Terminal strip 1 P1 P2 OUT1 J/V YELLOW YELLOW N RED BLACK BROWN L N GND MODBUS YEL GRN GND Terminal strip 2 IN-IN J/V RED BLUE PCB CN6 PCB T8 N SW1 DIP ON CN4 EGND 1 1 2 3 4 GND Vcc Vsp PG W V U CN-RAT1 AC-L 4 5 6 3 Vm AC-N OUT1 P1 SW1-4 OFF ON AC MF DC MF OUT2 CN-RAT2 OUT3 PCB OUT4 OUT5 H
RECYCLING THE HP When your HP reaches the end of its lifespan and you do not wish to keep it, do not throw it out with household waste. The HP must be brought to a selective recycling point for its reuse or recycling. It contains potentially hazardous substances that may harm the environment and that must, during recycling, be eliminated or neutralised.
Pentair International SARL, Ave. de Sévelin 20, CH-1004 - LAUSANNE, Switzerland Copyright - Limited license: unless expressly authorised herein, no part of the content of the present document can be reproduced in any form or by any means without the prior written authorisation by Pentair International SRL.