User Manual

IVTP-1M-DB
665mm 977 mm 431 mm 510 mm 410 mm 103 mm 290 mm
759 mm 1076 mm 494 mm 669 mm 465 mm 92 mm 320 mm
A
B C D E F G
IVTP-2M-DB
IVTP-3M-DB
IVTP-4M-DB
IVTP-5M-DB IVTP-6M-DB
pH +/-
B
A
D
E
C
G
F
INVERTEMP
DIMENSIONS:
HYDRAULIC CONNECTIONS:
Water quality necessary for this device: NF-EN-16713-3
The HP is compatible with all types of water treatment. The HP must imperatively be connected by a PVC pipe of Ø 50mm to the swimming pool’s hydraulic
circuit, after the lter and before the treatment system, regardless of its type (Cl, pH, Br metering pumps and/or electrolyser).
Follow the hydraulic connection order (blue = water in, red = water out)
A bypass must be installed to facilitate work on the HP.
Before connecting the PVC pipes to the HP, make sure the circuit is clean of any work residue (stone, soil, etc.).
Connection of the condensate evacuation pack:
During operations, the HP is subject to a condensation phenomenon. This translates into a water ow, which can be more or less important depending on the
degree of humidity. To channel this ow, which can represent several litres of water per day, we recommend you install the provided condensate evacuation pack
and connect it to a suitable water evacuation circuit.
Provided connections
(ø 50mm)
HP
Condensate evacuation
Bypass Bypass valve
(adjustment)
Open valve
Half-open valve
Closed valve
FROM THE SWIMMING POOL
TOWARDS THE SWIMMING
POOL
Water treatment (disinfection, pH correction)
located after the HP
Models