S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN AUTOMATIC S33A1 & S33A1C R 23833A587 Bag #18812A108
WARNING risk of electric shock. This pump is supplied with a grounding conductor and grounding-type attachment plug. To reduce the risk of electric shock, be certain that it is connected only to a properly grounded, grounding-type receptacle. Pumps can be installed with ABS, PVC or polyethylene plastic pipe, or galvanized or copper pipe. Proper adapters are required to connect plastic pipe to pump. The discharge is threaded for 1-1/2 inch pipe.
IMPORTANT INSTRUCTIONS BEFORE INSTALLATION Failure to follow these instructions may cause serious bodily injury and/or property damage. 5. Voltage of power supply must match the voltage of the pump. All Myers sump pumps are factory preset to 115V, 60Hz.
COMPLETE SUBMERSIBLE SUMP PUMP INSTALLATION Refer to the installation illustrations below and on the following page for the following instructions. Be certain sump basin is clean and all power to pump is shut off. If pump fails to operate properly after installation, refer to the troubleshooting checklist on page 6 or contact your Myers distributor. All parts with part numbers are quality Myers parts.
STARTING PUMP - S33A (AUTOMATIC) 1. These pumps have an integral mechanical (mercury-free) ball float switch as shown on installation drawing. “Vertical switch” models have a vertical actuated cylinder float. 2. Plug cord into a 115 volt GROUNDED RECEPTACLE. 3. Run water into sump until pump starts. 4. Allow pump to operate through several on-off cycles to be sure operation is satisfactory. 5. If shut-off valve is used in discharge line, be sure valve is open. 6.
23833A587 X Pump runs but does not deliver water. Pump runs but delivers only small amount of water. P. 6 Pump runs and pumps out sump but does not stop. X X X X X X X X Fuse blows or circuit breaker trips when pump starts. X X Motor runs for short time then stops. Then after short period starts again. Indicates tripping overload caused by symptom shown. X X X Defective motor stator; return to Myers service center. X Fuse size or circuit breaker is too small. Must be 15 amps.
MYERS LIMITED WARRANTY SUMP & RESIDENTIAL SEWAGE During the time periods and subject to the conditions hereinafter set forth, F.E. Myers will repair or replace to the original user or consumer any portion of your new MYERS product which proves defective due to defective materials or workmanship of MYERS. Contact your nearest Authorized MYERS Dealer for warranty service.