Use and Care Manual
PERFORMANCE DATA SHEET
Performance Data - Pentair Whole House Filters
Model Replacement Max Operating
Pressure
Rated Capacity Operating
Temp Range
Rated
Flow
Rated Pressure Drop
(At Rated Flow)
PC600-P PC600-R 25-80 PSI 662,400 gallons 36°F – 120°F 8 GPM 13 PSI
PC1000-P PC1000-R 25-80 PSI 1,324,800 gallons 36°F – 120°F 12 GPM 13 PSI
PC1354-P PC1354-R 25-80 PSI 1,987,200 gallons 36°F – 120°Fs 17 GPM 13 PSI
NSF/ANSI 42 Inuent Challenge
Chlorine
Minimum Required
Reduction
Average Reduction % Results
Chlorine Reduction,
Free Available
2 mg/L ±10% ≥50% 95.93% Pass
Performance Data - Pentair Whole House Filters
Model Accumulated
Volume (Gallons)
Chlorine, Free
Available (mg/L)
Flow Rate
(GPM)
Reduction %
Inuent Euent 1
PC600-P 650,885 2.05 0.07 8 GPM 96.6%
PC1000-P
PC1354-P
1,301,770
1,952,655
2.05
2.05
0.07
0.07
12 GPM
17 GPM
96.6%
96.6%
This system has been tested according to NSF/ANSI 42 for the reduction of the substances listed below. The concentration of
the indicated substances in the water entering the system was reduced to a concentration less than or equal to the permissible
limitforwaterleavingthesystem,asspeciedinNSF/ANSI42.
Statements: Testing was performed under standard laboratory
conditions, actual performance may vary. Filter usage must
comply with all state and local laws. Filter is only to be used
withcoldwater.Systemscertiedforcystreductionmay
beusedondisinfectedwatersthatmaycontainlterable
cysts.Allcontaminantsreducedbythislterarelisted.Notall
contaminants listed may be present in your water. Filter does not
remove all contaminants that may be present in tap water. See
owner’s manual for general installation conditions and needs as
well as manufacturer’s limited warranty.
CPELICAN WATER FILTER AND WATER SOFTENER ALTERNATIVE COMBO SYSTEM • 19