Use and Care Manual

WATER CONDITIONS FOR OPERATION
• Thewatershouldbefreeofhydrogensulde,adissolvedgaswithacharacteristicsmellofrotteneggs.Ifpresent,itcancoatthe
catalytic surface of the media and interfere with the process. The gas should be removed through adequate pre-treatment.
The water should be free of hydrocarbons, oils, and lubricants. If present, they can coat the catalytic surface of the media
and interfere with the process. Remove through adequate pre-treatment.
The water should contain less than 1 mg/l of phosphates. Phosphates sequester dissolved hardness molecules preventing
them from forming crystals and may coat the catalytic media surface and interfere with the process.
The copper level in the water supply should be below the MCL of 1.3mg/L. If copper is present above this level, it can attach to
the surface of the catalytic media and interfere with the process.
The water should be free of Iron and Manganese. If present, they can coat the catalytic surface of the media and interfere
with the process. Remove through adequate pre-treatment.
Homeowners Phone: 877.842.1635
Professionals Phone: 877.842.1635
Customer Service Contact Information Section
Specication Description PSE1800-P PSE2000-P
Rated Service Flow Rate 8 GPM 12 GPM
Peak Flow Rate 12 GPM 16 GPM
Minimum/Maximum Working Pressure 25-80 PSI
Maximum Vacuum 5 inch/127 mm Hg
Operating Temperatures 36°F – 120°F
pH Range 7 - 11
PRODUCT OPERATION AND SPECIFICATIONS
The WATER SOFTENER ALTERNATIVE WITH NATURSOFT® SALT-FREE TECHNOLOGY will be effective on water supplies with a maximum
hardness of 75 Grains per Gallon (GPG) or 1,282 ppm. For best results, all iron/manganese, sulfur and Tannin should be removed prior
to this system's installation.
CPELICAN WATER FILTER AND WATER SOFTENER ALTERNATIVE COMBO SYSTEM • 3