Use and Care Manual
WATER CONDITIONS FOR OPERATION
• Thewatershouldbefreeofhydrogensulde,adissolvedgaswithacharacteristicsmellofrotteneggs.Ifpresent,itcancoatthe
catalytic surface of the media and interfere with the process. The gas should be removed through adequate pre-treatment.
• The water should be free of hydrocarbons, oils, and lubricants. If present, they can coat the catalytic surface of the media
and interfere with the process. Remove through adequate pre-treatment.
• The water should contain less than 1 mg/l of phosphates. Phosphates sequester dissolved hardness molecules preventing
them from forming crystals and may coat the catalytic media surface and interfere with the process.
• The copper level in the water supply should be below the MCL of 1.3mg/L. If copper is present above this level, it can attach to
the surface of the catalytic media and interfere with the process.
• The water should be free of Iron and Manganese. If present, they can coat the catalytic surface of the media and interfere
with the process. Remove through adequate pre-treatment.
Homeowners Phone: 877.842.1635
Professionals Phone: 877.842.1635
Customer Service Contact Information Section
Specication Description PSE1800-P PSE2000-P
Rated Service Flow Rate 8 GPM 12 GPM
Peak Flow Rate 12 GPM 16 GPM
Minimum/Maximum Working Pressure 25-80 PSI
Maximum Vacuum 5 inch/127 mm Hg
Operating Temperatures 36°F – 120°F
pH Range 7 - 11
PRODUCT OPERATION AND SPECIFICATIONS
The WATER SOFTENER ALTERNATIVE WITH NATURSOFT® SALT-FREE TECHNOLOGY will be effective on water supplies with a maximum
hardness of 75 Grains per Gallon (GPG) or 1,282 ppm. For best results, all iron/manganese, sulfur and Tannin should be removed prior
to this system's installation.
CPELICAN WATER FILTER AND WATER SOFTENER ALTERNATIVE COMBO SYSTEM • 3