5. Technicaldata
Operatingvoltage: 12 V DC
or
2xLR14(C),1.5Valkalinebatteries
Powerconsumption: max.0.8mA/12 VDC(standby),
max.200mA/12 VDC(use)
Transmissionfrequency: 1880-1900MHz
Transmissionpower: <250mW
RFmodulation: GFSK
RFrangetobase: upto30mindoors,upto200minfreespace
Operatingtemperature: -20 °C to +50 °C (note: below 0°C the
transmissionrangecanbereduced)
Protectionclass: IP44
Dimensions: 60x175x34mm
Weight: approx.156g
Powersupply: 2xNi-MHbatteriesAAA,1.2V;600mAh
Chargingvoltage: frombase
Initialchargingduration: 15hours
Standbytime: upto180hours
Talktime: upto8hours
RFmodulation: GFSK
RFrangetobase: upto30mindoors,upto200minfreespace
Operatingtemperature: 0°Cto+40°C
Dimensions: approx.48x159x29mm
Weight: approx.132g
Operatingvoltage: 7.5 VDC(mainsadapter)
Currentconsumption: max.300A,
Operatingtemperature: 0°Cto+40°C
Dimensions: 115x115x68mm
Powersupply: 230V,50Hz,150mA
Poweroutput: 7.5 V,300mA,2.25VA
Application: indooruseonly
Operatingvoltage: 12 VDC,max.60mA
Switchingpower: 30 VDC,max.10A,
Switchingtime: 1-9sec.
Dimensions: 83x58x33mm
Application: indooruseonly
DoorunitTF04T
HandsetTF04M
BaseTF04B
Mainsadapter
RelaymoduleRE05
(min. 300 mA plus power
requirementofthedoorrelease)
6. Safetyinstructions
Thefollowinginstructionsareprovidedforyoursafetyandsatisfactionduring
operation of the machine. Note that non-observance of these safety
instructionsresultsinsignificantrisksofaccident.
Ifthispointisnotheeded,lifeandhealthareendangered.
Non-observanceoftheseinstructions putspropertyatrisk
ofdamage.
Optimumresultswillbeachievedbyobservingtheseinstructions.
Do not leave small children unsupervised with the product, packaging
material or small parts. Otherwise there is a risk of fatal injury due to
choking!
Do not damage any gas, electricity, water or telecommunication lines
during drilling and fixing work. Otherwise there are dangers ofpersonal
andfatalinjury!
Treat the supply lines carefully. Lay these so that they cannot be
damaged and do not present any tripping hazard. Fix the cables
sufficiently. Do not pull thecables oversharp edgesand donot crushor
crimpthemelsewhere.Otherwisetherearedangersofpersonalandfatal
injury!
Do not allow the product to have contact with moisture (except the door
unit: protection class IP44). Never immerse the product in water.
Otherwisethereisdangeroffatalinjury!
Do not use the handset in moist or explosion-risk environments.
Otherwisethereisdangeroffatalinjury!
Use only the supplied power mains adapter with the base. Before
connectingthistothemains,ensurethatthemainssupplycomplieswith
230VAC,50Hzandisfittedwithafuseaccordingtoregulations.
Use onlyrechargeable batteries of the same type in the handset. Do not
use primary batteries. Pay attention to the correct polarity. Otherwise
therearedangersofpersonalandfatalinjury!
Ensure that the batteries are not short circuited or exposed to fire. The
batteries must not be opened or recharged. Otherwise there is a risk of
fatalinjuryduetoexplosion!
Leaking or damaged batteries can cause burns by contact with skin.
Handletheseusingsuitableprotectivegloves.
The function of medicalapparatus canbe disturbed by the product. Pay
attention to technical constraints in the area of use, for example in
medicalpractices.Otherwisethereisariskoffatalinjury!
Note that the handset can cause an unpleasant humming sound in
hearingaids.
Explanationofsymbolsandtermsused:
Danger!
Attention!
Tip!
Danger!
!
!
!
!
!
!
!
!
!
!
!