Data Sheet

Germany: +49 621 776 1111Pepperl+Fuchs Group
Refer to "General Notes Relating to Pepperl+Fuchs Product Information".
USA: +1 330 486 0001 Singapore: +65 6779 9091
www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com fa-info@sg.pepperl-fuchs.com
fa-info@de.pepperl-fuchs.com
Inductive sensor NJ5-11-N-G-10M
3
Release date: 2019-05-15 17:04 Date of issue: 2019-05-15 306131_eng.xml
Data for application in connection with hazardous
areas
Equipment protection level Gb , Gc (ic) , Da , Mb
Equipment protection level Gb
Type of protection intrinsic safety
CE marking 0102
Certificates
Appropriate type
NJ 5-11-N...
ATEX certificate
PTB 00 ATEX 2048 X
ATEX marking
¬ II 2G Ex ia IIC T6T1 Gb
Standards
EN 60079-0:2012+A11:2013 , EN 60079-11:2012
IECEx certificate
IECEx PTB 11.0037X
IECEx marking
Ex ia IIC T6...T1 Gb
Standards
IEC 60079-0:2011 , IEC 60079-11:2011
Effective internal capacitance C
i
45 nF
A cable length of 10 m is considered.
Effective internal inductance L
i
50 µH
A cable length of 10 m is considered.
Maximum permissible ambient temperature T
amb
Also observe the maximum permissible ambient temperature stated in the general technical data.
Keep to the lower of the two values.
at U
i
= 16 V , I
i
= 25 mA , P
i
= 34 mW ,
T6 : 72 °C (161.6 °F)
T5 : 87 °C (188.6 °F)
T4 : 100 °C (212 °F)
T3 : 100 °C (212 °F)
T2 : 100 °C (212 °F)
T1 : 100 °C (212 °F)
at U
i
= 16 V , I
i
= 25 mA , P
i
= 64 mW ,
T6 : 65 °C (149 °F)
T5 : 80 °C (176 °F)
T4 : 100 °C (212 °F)
T3 : 100 °C (212 °F)
T2 : 100 °C (212 °F)
T1 : 100 °C (212 °F)
at U
i
= 16 V , I
i
= 52 mA , P
i
= 169 mW ,
T6 : 42 °C (107.6 °F)
T5 : 57 °C (134.6 °F)
T4 : 82 °C (179.6 °F)
T3 : 82 °C (179.6 °F)
T2 : 82 °C (179.6 °F)
T1 : 82 °C (179.6 °F)
at U
i
= 16 V , I
i
= 76 mA , P
i
= 242 mW ,
T6 : 26 °C (78.8 °F)
T5 : 41 °C (105.8 °F)
T4 : 63 °C (145.4 °F)
T3 : 63 °C (145.4 °F)
T2 : 63 °C (145.4 °F)
T1 : 63 °C (145.4 °F)