Frequency access method: programmable frequency list
Number of predefined channels: 10
Programmable channels: 1, 2, 3, ... 10
Center frequencies: 865.1 MHz, 865.3 MHz, 865.5 MHz, 865.7 MHz, 865.9 MHz,
866.1 MHz, 866.3 MHz, 866.5 MHz, 866.7 MHz, 866.9 MHz
Up to ten channels can be parameterized and used in sequence.
Default: dense reader mode on channel 1, 7, 4, 10. See chapter 3.2.6.
3.3.9 Japan
In Japan, the use of RFID in the UHF range is regulated as follows:
UHF frequency range: 916.7 MHz 920.5 MHz
Radiated power: 10 mW 4000 mW
EIRP
; Default = 800 mW
EIRP
(IUH-F192-V1-FR2)
Channel bandwidth: 200 kHz
Channel spacing: 1200 kHz
Frequency access method: programmable frequency list.
Number of predefined channels: 4
Programmable channels: 5, 11, 17, 23
Center frequencies: 916.8 MHz, 918.0 MHz, 919.2 MHz, 920.4 MHz
Up to four channels can be parameterized and used in sequence.
Default: dense reader mode on channel 5, 17, 11, 23. See chapter 3.2.6.
3.3.10 Colombia
The regulations for the UHF frequency range in Colombia are the same as the regulations for
the UHF frequency range in the USA. See chapter 3.3.19.
3.3.11 Malaysia
In Malaysia, the use of RFID in the UHF range is regulated as follows:
UHF frequency range: 919 MHz 923 MHz
Radiated power: 6 mW 2000 mW
ERP
; Default = 500 mW
ERP
(IUH-F192-V1-FR2)
Channel bandwidth: 500 kHz
Channel spacing: 500 kHz
Frequency access method: frequency hopping spread spectrum. See chapter 3.2.7.
Number of channels: 8
Channels used: 1, 2, 3, ... 8
Center frequencies: 918.75 MHz + (M x 0.5) MHz
All 8 channels are always used.
3.3.12 Morocco
In Morocco, the use of RFID in the UHF range is regulated in accordance with EN 302208:
UHF frequency range: 867.6 868.0 MHz
Radiated Power: 3 500 mW
erp
; Default = 50 mW
erp
Channel bandwidth: 200 kHz
Channel spacing: 200 kHz
Frequency access method: programmable frequency list.
Number of predefined channels: 1
Programmable channels: 1, 2
Center frequencies: 867.7 MHz, 867.9 MHz
Up to two channels can be parameterized simultaneously and used in sequence.